Jiarui Yang

Dr. Jiarui Yang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2023 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
SZSue Zhang
Sue Zhang
GGGabrielle Grifno
Gabrielle Grifno
RPRachel Passaro
Rachel Passaro
KRKathryn Regan
Kathryn Regan
SZSiyi Zheng
Siyi Zheng
HNHadi T. Nia
Hadi T. Nia

21 October 2020 in Neurophotonics
Verified
Journal Article
Open access
PDF file
JYJiarui Yang
Jiarui Yang
ICIchun Anderson Chen
Ichun Anderson Chen
SCShuaibin Chang
Shuaibin Chang
JTJianbo Tang
Jianbo Tang
BLBlaire Lee
Blaire Lee
DBDavid A. Boas
David A. Boas
Optical coherence tomography (OCT) is a volumetric imaging technique that has been widely used to image the microstructure of biological samples.1 The OCT signal originates from back-scattered photons and provides image contrast that reflects intrinsic differences in tissue properties within the sample. The depth profile of the OCT signal is determined by five factors: the refraction index of the sample, the optical attenuation coefficient, the back-scattering coefficient, the numerical aperture (NA) of focusing optics, and the depth of the focus in the sample.2 The attenuation coefficient, i.e., the sum of the tissue scattering and absorption coefficients, is a spatially varying intrinsic property of the sample and is independent of the optics and the incident power of the system. For low-NA OCT systems, where the lateral resolution is typically larger than 10  μm and the confocal parameter (i.e., two times the Rayleigh range) is comparable to or larger than the imaging depth, a single-scattering exponential model is appropriate to describe OCT signal attenuation versus depth.3,4 Previous studies have shown that extracting the attenuation coefficient from low-NA OCT measurements based on Beer’s law is useful in quantifying the optical properties of the sample for applications, including detecting cancerous tissue in skin, bladder, and brain,5 – 7 monitoring blood glucose concentration,8 characterizing atherosclerosis plaques3,9 and correlating collagen content with histological staining.10 However, for high-NA OCT systems where the lateral resolution reaches a few microns or less, the shape of the axial point spread function (PSF) plays an important role in modulating the OCT signal depth profile, and thus the effect of the confocal parameter and focus depth cannot be neglected when estimating the optical properties of the sample.4,11 We have previously shown that OCT with a 3.5-μm lateral resolution is able to differentiate laminar structures in the neocortex of human brain samples using the average intensity projection (AIP) over the effective Rayleigh range.2,12 Moreover, we showed that estimating the intrinsic optical properties of the sample could provide additional information to differentiate brain structures, albeit with high inter-parameter correlations that resulted in large variance.2

16 September 2021 in Progress in Biophysics and Molecular Biology
Verified
Journal Article
Open access
LPLuca Pesce
Luca Pesce
ALAnnunziatina Laurino
Annunziatina Laurino
MSMarina Scardigli
Marina Scardigli
JYJiarui Yang
Jiarui Yang
DBDavid A. Boas
David A. Boas
FPFrancesco Saverio Pavone
Francesco Saverio Pavone
Cover-all mapping of the distribution of neurons in the human brain would have a significant impact on the deep understanding of brain function. Therefore, complete knowledge of the structural organization of different human brain regions at the cellular level would allow understanding their role in the functions of specific neural networks. Recent advances in tissue clearing techniques have allowed important advances towards this goal. These methods use specific chemicals capable of dissolving lipids, making the tissue completely transparent by homogenizing the refractive index. However, labeling and clearing human brain samples is still challenging. Here, we present an approach to perform the cellular mapping of the human cerebral cortex coupling immunostaining with SWITCH/TDE clearing and confocal microscopy. A specific evaluation of the contributions of the autofluorescence signals generated from the tissue fixation is provided as well as an assessment of lipofuscin pigments interference. Our evaluation demonstrates the possibility of obtaining an efficient clearing and labeling process of parts of adult human brain slices, making it an excellent method for morphological classification and antibody validation of neuronal and non-neuronal markers.

13 May 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JYJiarui Yang
Jiarui Yang
SCShuaibin Chang
Shuaibin Chang
ICIchun Anderson Chen
Ichun Anderson Chen
SKSreekanth Kura
Sreekanth Kura
GRGrace A. Rosen
Grace A. Rosen
HWHui Wang
Hui Wang
Objective: Serial sectioning optical coherence tomography (OCT) enables accurate volumetric reconstruction of several cubic centimeters of human brain samples. We aimed to identify anatomical features of the ex vivo human brain, such as intraparenchymal blood vessels and axonal fiber bundles, from the OCT data in 3D, using intrinsic optical contrast. Methods: We developed an automatic processing pipeline to enable characterization of the intraparenchymal microvascular network in human brain samples. Results: We demonstrated the automatic extraction of the vessels down to a 20 ${\boldsymbol{\mu }}$ m in diameter using a filtering strategy followed by a graphing representation and characterization of the geometrical properties of microvascular network in 3D. We also showed the ability to extend this processing strategy to extract axonal fiber bundles from the volumetric OCT image. Conclusion: This method provides a viable tool for quantitative characterization of volumetric microvascular network as well as the axonal bundle properties in normal and pathological tissues of the ex vivo human brain.

3 February 2020 in IEEE Access
Verified
Journal Article
Open access
SJSeongah Jeong
Seongah Jeong
Xiang LiXiang Li
Xiang Li
JYJiarui Yang
Jiarui Yang
Quanzheng LiQuanzheng Li
Quanzheng Li
VTVahid Tarokh
Vahid Tarokh
In the field of neuroimaging and cognitive neuroscience, functional Magnetic Resonance Imaging (fMRI) has been widely used to study the functional localization and connectivity of the brain. However, the inherently low signal-to-noise ratio (SNR) of the fMRI signals greatly limits the accuracy and resolution of current studies. In addressing this fundamental challenge in fMRI analytics, in this work we develop and implement a denoising method for task fMRI (tfMRI) data in order to delineate the high-resolution spatial pattern of the brain activation and functional connectivity via dictionary learning and sparse coding (DLSC). In addition to the traditional unsupervised dictionary learning model which has shown success in image denoising, we further utilize the prior knowledge of task paradigm to learn a dictionary consisting of both data-driven and model-driven terms for a more stable sparse representation of the data. The proposed method is applied to preprocess the motor tfMRI dataset from Human Connectome Project (HCP) for the purpose of brain activation detection and functional connectivity estimation. Comparison between the results from original and denoised fMRI data shows that the disruptive brain activation and functional connectivity patterns can be recovered, and the prominence of such patterns is improved through denoising. The proposed method is then compared with the temporal non-local means (tNLM)-based denoising method and shows consistently superior performance in various experimental settings. The promising results show that the proposed DLSC-based fMRI denoising method can effectively reduce the noise level of the fMRI signals and increase the interpretability of the inferred results, therefore constituting a crucial part of the preprocessing pipeline and provide the foundation for further high-resolution functional analysis.

25 October 2024 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Open access
PDF file
HZHuan Zhang
Huan Zhang
YXYue Xing
Yue Xing
LWLingyun Wang
Lingyun Wang
YHYangfan Hu
Yangfan Hu
ZXZhihan Xu
Zhihan Xu
JZJingyu Zhong
Jingyu Zhong
This study aimed to investigate the potential benefit of ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) angiography in visualization of abdominal arteries in comparison to standard-reconstruction (SR) images of virtual monoenergetic images (VMI) at low kiloelectron volt (keV). We prospectively included 47 and 47 participants to undergo contrast-enhanced abdominal CT scans within UHR mode on a PCD-CT system using full-dose (FD) and low-dose (LD) protocols, respectively. The data were reconstructed into six series of images: FD_UHR_Br48, FD_UHR_Bv56, FD_UHR_Bv60, FD_SR_Bv40, LD_UHR_Bv48, and LD_SR_Bv40. The UHR reconstructions were performed with three kernels (Bv48, Bv56, and Bv60) within 0.2 mm. The SR were virtual monoenergetic imaging reconstruction with Bv40 kernel at 40-keV within 1 mm. Each series of axial images were reconstructed into coronal and volume-rendered images. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of seven arteries were measured. Three radiologists assessed the image quality, and visibility of nine arteries on all the images. SNR and CNR values of SR images were significantly higher than those of UHR images (P < 0.001). The SR images have higher ratings in image noise (P < 0.001), but the FD_UHR_Bv56 and FD_UHR_Bv60 images has higher rating in vessel sharpness (P < 0.001). The overall quality was not significantly different among FD_VMI_40keV, LD_VMI_40keV, FD_UHR_Bv48, and LD_UHR_Bv48 images (P > 0.05) but higher than those of FD_UHR_Bv56 and FD_UHR_Bv60 images (P < 0.001). There is no significant difference of nine abdominal arteries among six series of images of axial, coronal and volume-rendered images (P > 0.05). To conclude, 1-mm SR image of VMI at 40-keV is superior to 0.2-mm UHR regardless of which kernel is used to visualize abdominal arteries, while 0.2-mm UHR image using a relatively smooth kernel may allow similar image quality and artery visibility when thinner slice image is warranted.