Ya-Hui Lin

Dr. Ya-Hui Lin


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
CLChih-Sheng Lin
Chih-Sheng Lin
BPBing-Ru Peng
Bing-Ru Peng
HMHong-Bing Ma
Hong-Bing Ma
KCKelin Chen
Kelin Chen
TLTsung-Han Lin
Tsung-Han Lin
YLYa-Hui Lin
Ya-Hui Lin
This study mitigated the challenge of head and neck CT angiography by IPA-based time-resolved imaging of contrast kinetics. To this end, 627 cerebral hemorrhage patients with dizziness, brain aneurysm, stroke, or hemorrhagic stroke diagnosis were randomly categorized into three groups, namely, the original dataset (450), verification group (112), and in vivo testified group (65), in the Affiliated BenQ Hospital of Nanjing Medical University. In the first stage, seven risk factors were assigned: age, CTA tube voltage, body surface area, heart rate per minute, cardiac output blood per minute, the actual injected amount of contrast media, and CTA delayed trigger timing. The expectation value of the semi-empirical formula was the CTA number of the patient’s left artery (LA). Accordingly, 29 items of the first-order nonlinear equation were calculated via the inverse problem analysis (IPA) technique run in the STATISTICA 7.0 program, yielding a loss function and variance of 3.1837 and 0.8892, respectively. A dimensionless AT was proposed to imply the coincidence, with a lower AT indicating a smaller deviation between theoretical and practical values. The derived formula was confirmed for the verification group of 112 patients, reaching high coincidence, with average ATavg and standard deviation values of 3.57% and 3.06%, respectively. In the second stage, the formula was refined to find the optimal amount of contrast media for the CTA number of LA approaching 400. Finally, the above procedure was applied to head and neck CTA images of the third group of 65 patients, reaching an average CTA number of LA of 407.8 ± 16.2 and finding no significant fluctuations.

24 August 2024 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Closed access
YLYa-Hui Lin
Ya-Hui Lin
KCKelin Chen
Kelin Chen
KHKai-Yu Hsiao
Kai-Yu Hsiao
HHHsin-Tzu Huang
Hsin-Tzu Huang
CCChing-Yuan Chen
Ching-Yuan Chen
BPBing-Ru Peng
Bing-Ru Peng

17 February 2026 in Technology and Health Care
Verified
Journal Article
Closed access
TLTsung-Han Lin
Tsung-Han Lin
SHShih-Hsun Huang
Shih-Hsun Huang
KWKeng-Yi Wu
Keng-Yi Wu
TCTzu-Hsien Chao
Tzu-Hsien Chao
LPLung-Kwang Pan
Lung-Kwang Pan
BPBing-Ru Peng
Bing-Ru Peng
This study simulated valproic acid (VPA) physiological pharmacokinetics for epilepsy patients via a refined seven-compartmental model. The seven compartments were defined as oral, GI Tract, liver, whole body (WB), cerebrospinal fluid (CSF), kidney, and bladder. A first-order system of seven differential equations was defined according to this specific model and solved by a self-developed program run in MATLAB to evaluate the VPA time-dependent change among compartments. Each compartment's preset dissolving half-life (in hours) was as follows: oral 0.05, GI Tract 0.10, liver 0.5, WB 2.2, CSF 0.8, kidney 1.2, and bladder 0.5, respectively. The derived results were reorganized according to various presets of dissolving half-lives of the liver, WB, CSF, or kidney to analyze the VPA time-dependent changes under various scenarios. Either the liver or WB was the dominant compartment in this model, which mainly controlled the VPA changes. In contrast, others compartments followed the principle of secular equilibrium in the chain decay of radioactive nuclides. Accordingly, the VPA degradation changes in WB (“mother” compartment) mainly affected the VPA changes in other (“daughter”) compartments. Thus, the predicted VPA degradation in CSF, kidney, or bladder was always longer than in WB despite its dissolving half-life changes. The predicted results of VPA changes in various compartments were also compared with other studies, and a reasonable agreement was reached on whether the dissolving half-life of the liver or WB ranged from the original 0.2/2.2 to 1.4/0.9 h. The programable capability of this self-developed program allows one to easily modify the primary preset to comply with findings from other studies and has great potential in similar applications.