This study optimized the ultrasound image of carotid artery stenosis using Taguchi dynamic analysis and an indigenous water phantom. Eighteen combinations of seven essential factors of the ultrasound scan facility were organized according to Taguchi’s L18 orthogonal array. The seven factors were assigned as follows: (1) angle of probe; (2) signal gain; (3) resolution vs. speed; (4) dynamic range; (5) XRES; (6) zoom; (7) time gain compensation. An indigenous water phantom was customized to satisfy the quantified need in Taguchi’s analysis. Unlike the conventional dynamic Taguchi analysis, an innovative quantified index, the figure of merit (FOM), was proposed to integrate four specific quality characteristics, namely (i) average difference between the practical scan and theoretically preset area (78.5, 50.2 and 12.6 mm2) of stenosis, (ii) standard deviation of the average, (iii) practical scan’s sensitivity β to various stenosis diameters (10, 8, and 4 mm), and (iv) correlation coefficient r2 of the linear regressed sensitivity curve. The highest value (FOM = 0.413) was furnished by the optimal combination of factors on 18 groups under study, yielding high r2 and low β or standard deviation values and the best quality of ultrasound images for the further clinical diagnosis. The comparison between FOM and the conventional signal-to-noise (S/N) ratio in Taguchi’s analysis revealed that FOM compiled more quality characteristics that were superior by nature to fulfill the practical need in clinical diagnosis. The alternative choice in ultrasound scan optimization can be based on stenosis diameter variation from a different perspective to be explored in the follow-up study.

24 August 2024 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Closed access
YLYa-Hui Lin
Ya-Hui Lin
KCKelin Chen
Kelin Chen
KHKai-Yu Hsiao
Kai-Yu Hsiao
HHHsin-Tzu Huang
Hsin-Tzu Huang
CCChing-Yuan Chen
Ching-Yuan Chen
BPBing-Ru Peng
Bing-Ru Peng