Jabir Massoud

Dr. Jabir Massoud


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
Sheeraz IqbalSheeraz Iqbal
Sheeraz Iqbal
NANahar F Alshammari
Nahar F Alshammari
Mokhtar ShouranMokhtar Shouran
Mokhtar Shouran
JMJabir Massoud
Jabir Massoud
This study addresses the challenges associated with electric vehicle (EV) charging in office environments. These challenges include (1) reliance on manual cable connections, (2) constrained charging options, (3) safety concerns with cable management, and (4) the lack of dynamic charging capabilities. This research focuses on an innovative wireless power transfer (WPT) system specifically designed for use in office parking areas. This system incorporates renewable energy resources (RERs) and uses the transformative power of the Internet of Things (IoT). It employs a mix of solar energy systems and battery storage solutions to facilitate a sustainable and efficient energy supply to EVs. The integration of IoT technology allows for the automatic initiation of charging as soon as an EV is parked. Additionally, the implementation of the Blynk application offers users real-time access to information regarding the operational status of the photovoltaic system and the battery levels of their EVs. The system is further enhanced with IoT and RFID technologies to provide dynamic updates on the availability of charging slots and to implement strict security protocols for user authentication and protection. The research also includes a case study focusing on the application of this charging system in office settings. The case study achieves a 95.9% IRR, lower NPC of USD 1.52 million, and 56.7% power contribution by RERs, and it reduces annual carbon emissions to 173,956 kg CO2.

11 April 2024 in Frontiers in Energy Research
Verified
Journal Article
Open access
CRCh. S. V. Prasada Rao
Ch. S. V. Prasada Rao
APA. Pandian
A. Pandian
Ch. Rami ReddyCh. Rami Reddy
Ch. Rami Reddy
MBMohit Bajaj
Mohit Bajaj
JMJabir Massoud
Jabir Massoud
MSMokhtar Shouran
Mokhtar Shouran
This manuscript proposes a novel hybrid artificial intelligence (AI) approach for a unified power quality conditioner (UPQC) designed specifically for electric vehicle charging stations (EVCSs). The aim is to integrate multiple vehicle-to-grid (V2G) functionalities, thereby mitigating the challenges associated with electric vehicle (EV) grid integration and the incorporation of distributed energy resources (DERs). The hybrid technique presented in this manuscript combines the gradient boosting decision tree (GBDT) algorithm and the jellyfish search (JS) algorithm, referred to as the GBDT–JS technique. This innovative approach involves utilizing the charging station to offer EV charging services and facilitating the discharge of EVs to the power grid. Integration of the UPQC with DERs, such as photovoltaic (PV), is implemented to decrease the power rating of converters and fulfill power demand requirements. The initial converter within the UPQC is employed to manage the direct current (DC) voltage, while the second converter oversees the power charging or discharging processes of EVs. Additionally, it mitigates the impact of battery voltage fluctuations. The UPQC with vehicle-to-grid functionality minimizes the load pressure on the grid, preventing over-current issues. The presented approach regulates the UPQC converters to mitigate power quality issues such as harmonic currents and voltage sags. Subsequently, the effectiveness of this technique is demonstrated using the MATLAB/Simulink operating platform. The evaluation of GBDT–JS performance involves a comparative analysis with existing techniques. This assessment reveals that the proposed method effectively alleviates power quality issues, specifically reducing total harmonic distortion (THD), and delivers optimal outcomes.

8 March 2025 in Energies
Verified
Journal Article
Open access
PDF file
Mokhtar ShouranMokhtar Shouran
Mokhtar Shouran
MAMohammed Alenezi
Mohammed Alenezi
MMMohamed Naji Muftah
Mohamed Naji Muftah
AAAbdalmajid Almarimi
Abdalmajid Almarimi
AAAbdalghani Abdallah
Abdalghani Abdallah
JMJabir Massoud
Jabir Massoud
Power system stability is managed through various control loops, including the Automatic Voltage Regulator (AVR), which regulates the terminal voltage of synchronous generators. This study integrated Fuzzy Logic Control (FLC) and a Proportional–Integral–Derivative controller with Filtered derivative action (PIDF) to propose a hybrid Fuzzy PIDF controller enhanced by Fractional-Order Proportional-Derivative (FOPD) for AVR applications. For the first time, the newly introduced Sand Cat Swarm Optimization (SCSO) algorithm was applied to the AVR system to tune the parameters of the proposed fuzzy controller. The SCSO algorithm has been recognized as a powerful optimization tool and has demonstrated success across various engineering applications. The well-known Particle Swarm Optimization (PSO) algorithm was also utilized in this study to optimize the gains of the proposed controller. The Fuzzy PIDF plus FOPD is a novel configuration that is designed to be a robust control technique for AVR to achieve an excellent performance. In this research, the Fuzzy PIDF + FOPD controller was optimized using the PSO and SCSO algorithms by minimizing the Integral Time Absolute Error (ITAE) objective function to enhance the overall performance of AVR systems. A comparative analysis was conducted to evaluate the superiority of the proposed approach by benchmarking the results against those of other controllers reported in the literature. Furthermore, the robustness of the controller was assessed under parametric uncertainties and varying load disturbances. Also, its robustness was examined against disturbances in the control signal. The results demonstrate that the proposed Fuzzy PIDF + FOPD controller tuned by the PSO and SCSO algorithms delivers exceptional performance as an AVR controller, outperforming other controllers. Additionally, the findings confirm the robustness of the Fuzzy PIDF + FOPD controller against parametric uncertainties, establishing its potential for a successful implementation in real-time applications.

13 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
MAMohammed Alenezi
Mohammed Alenezi
JMJabir Massoud
Jabir Massoud
TGTarek Ghomeed
Tarek Ghomeed
Mokhtar ShouranMokhtar Shouran
Mokhtar Shouran
This paper introduces an intelligent fault-diagnosis framework for power transformers that integrates hybrid machine-learning models with nature-inspired optimization. Current signals were acquired from a laboratory-scale three-phase transformer under both healthy and various fault conditions. A suite of 41 discriminative features was engineered from time–frequency and sparse representations generated via Discrete Wavelet Transform (DWT) and Matching Pursuit (MP). The resulting dataset of 2400 labeled segments was used to develop four hybrid models, PSO-SVM, PSO-RF, BA-SVM, and BA-RF, wherein Particle Swarm Optimization (PSO) and the Bees Algorithm (BA) served as wrapper optimizers for simultaneous feature selection and hyperparameter tuning. Rigorous evaluation with 5-fold and 10-fold cross-validation demonstrated the superior performance of Random Forest-based models, with the BA-RF hybrid achieving peak performance (98.33% accuracy, 99.09% precision). The results validate the proposed methodology, establishing that the fusion of wavelet- and MP-based feature extraction with metaheuristic optimization constitutes a robust and accurate paradigm for transformer fault diagnosis.