Xingran CUI

Dr. Xingran CUI

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
WWWang Wan
Wang Wan
XCXingran CUI
Xingran CUI
ZGZhilin Gao
Zhilin Gao
ZGZhongze Gu
Zhongze Gu
Measuring and identifying the specific level of sustained attention during continuous tasks is essential in many applications, especially for avoiding the terrible consequences caused by reduced attention of people with special tasks. To this end, we recorded EEG signals from 42 subjects during the performance of a sustained attention task and obtained resting state and three levels of attentional states using the calibrated response time. EEG-based dynamical complexity features and Extreme Gradient Boosting (XGBoost) classifier were proposed as the classification model, Complexity-XGBoost, to distinguish multi-level attention states with improved accuracy. The maximum average accuracy of Complexity-XGBoost were 81.39 ± 1.47% for four attention levels, 80.42 ± 0.84% for three attention levels, and 95.36 ± 2.31% for two attention levels in 5-fold cross-validation. The proposed method is compared with other models of traditional EEG features and different classification algorithms, the results confirmed the effectiveness of the proposed method. We also found that the frontal EEG dynamical complexity measures were related to the changing process of response during sustained attention task. The proposed dynamical complexity approach could be helpful to recognize attention status during important tasks to improve safety and efficiency, and be useful for further brain-computer interaction research in clinical research or daily practice, such as the cognitive assessment or neural feedback treatment of individuals with attention deficit hyperactivity disorders, Alzheimer’s disease, and other diseases which affect the sustained attention function.

20 June 2019 in Entropy
Verified
Journal Article
Open access
PDF file
ZGZhilin Gao
Zhilin Gao
XCXingran CUI
Xingran CUI
WWWang Wan
Wang Wan
ZGZhongze Gu
Zhongze Gu
Exploring the manifestation of emotion in electroencephalogram (EEG) signals is helpful for improving the accuracy of emotion recognition. This paper introduced the novel features based on the multiscale information analysis (MIA) of EEG signals for distinguishing emotional states in four dimensions based on Russell’s circumplex model. The algorithms were applied to extract features on the DEAP database, which included multiscale EEG complexity index in the time domain, and ensemble empirical mode decomposition enhanced energy and fuzzy entropy in the frequency domain. The support vector machine and cross validation method were applied to assess classification accuracy. The classification performance of MIA methods (accuracy = 62.01%, precision = 62.03%, recall/sensitivity = 60.51%, and specificity = 82.80%) was much higher than classical methods (accuracy = 43.98%, precision = 43.81%, recall/sensitivity = 41.86%, and specificity = 70.50%), which extracted features contain similar energy based on a discrete wavelet transform, fractal dimension, and sample entropy. In this study, we found that emotion recognition is more associated with high frequency oscillations (51–100Hz) of EEG signals rather than low frequency oscillations (0.3–49Hz), and the significance of the frontal and temporal regions are higher than other regions. Such information has predictive power and may provide more insights into analyzing the multiscale information of high frequency oscillations in EEG signals.

10 December 2017 in Entropy
Verified
Journal Article
Open access
PDF file
XCXingran CUI
Xingran CUI
ECEmily Chang
Emily Chang
WYWen-Hung Yang
Wen-Hung Yang
BJBernard Jiang
Bernard Jiang
AYAlbert Yang
Albert Yang
CPChung-Kang Peng
Chung-Kang Peng
Atrial fibrillation (AF) is an abnormal rhythm of the heart, which can increase heart-related complications. Paroxysmal AF episodes occur intermittently with varying duration. Human-based diagnosis of paroxysmal AF with a longer-term electrocardiogram recording is time-consuming. Here we present a fully automated ensemble model for AF episode detection based on RR-interval time series, applying a novel approach of information-based similarity analysis and ensemble scheme. By mapping RR-interval time series to binary symbolic sequences and comparing the rank-frequency patterns of m-bit words, the dissimilarity between AF and normal sinus rhythms (NSR) were quantified. To achieve high detection specificity and sensitivity, and low variance, a weighted variation of bagging with multiple AF and NSR templates was applied. By performing dissimilarity comparisons between unknown RR-interval time series and multiple templates, paroxysmal AF episodes were detected. Based on our results, optimal AF detection parameters are symbolic word length m = 9 and observation window n = 150, achieving 97.04% sensitivity, 97.96% specificity, and 97.78% overall accuracy. Sensitivity, specificity, and overall accuracy vary little despite changes in m and n parameters. This study provides quantitative information to enhance the categorization of AF and normal cardiac rhythms.

15 November 2020 in Entropy
Verified
Journal Article
Open access
PDF file
XCXingran CUI
Xingran CUI
LTLeirong Tian
Leirong Tian
ZLZhengwen Li
Zhengwen Li
ZRZikai Ren
Zikai Ren
KZKeyang Zha
Keyang Zha
CPChung-Kang Peng
Chung-Kang Peng
Heart rate variability (HRV) has been widely used as indices for autonomic regulation, including linear analyses, entropy and multi-scale entropy based nonlinear analyses, and however, it is strongly influenced by the conditions under which the signal is being recorded. To investigate the variability of healthy HRV under different settings, we recorded electrocardiograph (ECG) signals from 56 healthy young college students (20 h for each participant) at campus using wearable single-lead ECG device. Accurate R peak to R peak (RR) intervals were extracted by combing the advantages of five commonly used R-peak detection algorithms to eliminate data quality influence. Thorough and detailed linear and nonlinear HRV analyses were performed. Variability of HRV metrics were evaluated from five categories: (1) different states of daily activities; (2) different recording time period in the same day during free-running daily activities; (3) body postures of sitting and lying; (4) lying on the left, right and back; and (5) gender influence. For most of the analyzed HRV metrics, significant differences (p < 0.05) were found among different recording conditions within the five categories except lying on different positions. Results suggested that the standardization of ECG data collection and HRV analysis should be implemented in HRV related studies, especially for entropy and multi-scale entropy based analyses. Furthermore, this preliminary study provides reference values of HRV indices under various recording conditions of healthy young subjects that could be useful information for different applications (e.g., health monitoring and management).

9 June 2023 in Physica A: Statistical Mechanics and its Applications
Verified
Journal Article
Closed access
WWWang Wan
Wang Wan
ZGZhilin Gao
Zhilin Gao
QZQiuchi Zhang
Qiuchi Zhang
ZGZhongze Gu
Zhongze Gu
CCCheng Chang
Cheng Chang
XCXingran CUI
Xingran CUI

1 December 2021 in Data in Brief
Verified
Journal Article
Open access
ZGZhilin Gao
Zhilin Gao
XCXingran CUI
Xingran CUI
WWWang Wan
Wang Wan
WZWenming Zheng
Wenming Zheng
ZGZhongze Gu
Zhongze Gu
This paper described the collection of multi-modal physiological signals, which include electroencephalography, electrocardiograph (ECG), photoplethysmography, electrodermal activity, temperature, and accelerometer data, recorded from 89 healthy college students during resting state, the emotion induction and recovery, and a set of cognitive function assessment tasks. Emotion, sleep, cognition, depression, mood, and other factors were evaluated through different methods, and were included in this dataset. Six emotions (neutral, fear, sad, happy, anger, and disgust) were induced by movie clips. The cognitive functions such as sustained attention, response inhibition, working memory, and strategy use, were quantitatively measured by Cambridge neuropsychological test automatic battery. The sleep ECG was collected the night before the emotion-induction experiment, and the sleep quality was analysed based on the sleep ECG. After the experiment, the participants were required to fill in questionnaires to evaluate the emotion regulation strategies, depression score, recent mood, and sleep quality index. The database can not only be directly used for the research of emotion recognition on multi-modal physiological signals, but also can further explore the interactions between emotion, cognition, and sleep.