Bernard Jiang

Dr. Bernard Jiang


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2013 in Sensors
Verified
Journal Article
Open access
PDF file
CHCheng-Wei Huang
Cheng-Wei Huang
PSPei-Der Sue
Pei-Der Sue
Maysam AbbodMaysam Abbod
Maysam Abbod
BJBernard Jiang
Bernard Jiang
Jiann-Shing ShiehJiann-Shing Shieh
Jiann-Shing Shieh
To assess the improvement of human body balance, a low cost and portable measuring device of center of pressure (COP), known as center of pressure and complexity monitoring system (CPCMS), has been developed for data logging and analysis. In order to prove that the system can estimate the different magnitude of different sways in comparison with the commercial Advanced Mechanical Technology Incorporation (AMTI) system, four sway tests have been developed (i.e., eyes open, eyes closed, eyes open with water pad, and eyes closed with water pad) to produce different sway displacements. Firstly, static and dynamic tests were conducted to investigate the feasibility of the system. Then, correlation tests of the CPCMS and AMTI systems have been compared with four sway tests. The results are within the acceptable range. Furthermore, multivariate empirical mode decomposition (MEMD) and enhanced multivariate multiscale entropy (MMSE) analysis methods have been used to analyze COP data reported by the CPCMS and compare it with the AMTI system. The improvements of the CPCMS are 35% to 70% (open eyes test) and 60% to 70% (eyes closed test) with and without water pad. The AMTI system has shown an improvement of 40% to 80% (open eyes test) and 65% to 75% (closed eyes test). The results indicate that the CPCMS system can achieve similar results to the commercial product so it can determine the balance.

10 December 2017 in Entropy
Verified
Journal Article
Open access
PDF file
XCXingran CUI
Xingran CUI
ECEmily Chang
Emily Chang
WYWen-Hung Yang
Wen-Hung Yang
BJBernard Jiang
Bernard Jiang
AYAlbert Yang
Albert Yang
CPChung-Kang Peng
Chung-Kang Peng
Atrial fibrillation (AF) is an abnormal rhythm of the heart, which can increase heart-related complications. Paroxysmal AF episodes occur intermittently with varying duration. Human-based diagnosis of paroxysmal AF with a longer-term electrocardiogram recording is time-consuming. Here we present a fully automated ensemble model for AF episode detection based on RR-interval time series, applying a novel approach of information-based similarity analysis and ensemble scheme. By mapping RR-interval time series to binary symbolic sequences and comparing the rank-frequency patterns of m-bit words, the dissimilarity between AF and normal sinus rhythms (NSR) were quantified. To achieve high detection specificity and sensitivity, and low variance, a weighted variation of bagging with multiple AF and NSR templates was applied. By performing dissimilarity comparisons between unknown RR-interval time series and multiple templates, paroxysmal AF episodes were detected. Based on our results, optimal AF detection parameters are symbolic word length m = 9 and observation window n = 150, achieving 97.04% sensitivity, 97.96% specificity, and 97.78% overall accuracy. Sensitivity, specificity, and overall accuracy vary little despite changes in m and n parameters. This study provides quantitative information to enhance the categorization of AF and normal cardiac rhythms.

6 January 2019
Verified
Book Chapter
Closed access
PDF file
CLChia Hsuan Lee
Chia Hsuan Lee
TSTien-Lung Sun
Tien-Lung Sun
DFDiana Eloisa Roa Flores
Diana Eloisa Roa Flores
BJBernard Jiang
Bernard Jiang