This paper presents a Piezoelectric micromechanical ultrasonic transducer (PMUT) based on a Pt/ScAlN/Mo/SiO2/Si/SiO2/Si multilayer structure with a circular suspension film of scandium doped aluminum nitride (ScAlN). Multiphysics modeling using the finite element method and analysis of the effect of different Sc doping concentrations on the resonant frequency, the effective electromechanical coupling coefficient () and the station sensitivity of the PMUT cell are performed. The calculation results show that the resonant frequency of the ScAlN-based PMUT can be above 20 MHz and its monotonically rise with the increasing doping concentrations in ScAlN. In comparison to the pure AlN thin film-based PMUT, the static receiving sensitivity of the PMUT based on ScAlN thin film with 35% Sc doping concentration is up to 1.61 mV/kPa. Meanwhile, the static transmitting sensitivity of the PMUT is improved by 152.95 pm/V. Furthermore, the relative pulse-echo sensitivity level of the 2 × 2 PMUT array based on the Sc doping concentration of 35% AlN film is improved by 16 dB compared with that of the cell with the same Sc concentration. The investigation results demonstrate that the performance of PMUT on the proposed structure can be tunable and enhanced by a reasonable choice of the Sc doping concentration in ScAlN films and structure optimization, which provides important guidelines for the design of PMUT for practical applications.
Piezoelectric micromachined ultrasonic transducers (PMUTs) have attracted widespread attention due to their high performance, miniaturization, and easy integration with semiconductor processes. In this paper, a PMUT device based on high-performance and lead-free Na0.5Bi0.5TiO3-BaTiO3 (NBBT) piezoelectric single-crystal thin films was designed for the application of medical high-frequency ultrasonics. Three-dimensional modeling and analysis of PMUT elements on the proposed structure were performed via the finite element method. The relationship between structure configuration in terms of the top electrode and the cavity shape of the bottom was studied. The PMUT properties and its device performance, including resonant frequency, effective electromechanical coupling factor (), and the static sensitivity of different device structures, were analyzed. In addition, by rotating the Euler Angle of the NBBT piezoelectric single-crystal film, the static sensitivity and of the model are improved to 1.34 when is rotated to 45 ± 5°. It was shown that the PMUT using rotated NBBT demonstrated an enhanced relative pulse-echo sensitivity of −46 dB and a bandwidth of 35% when the reflective surface was 200 μm. We conclude that the PMUT in accordance with an NBBT piezoelectric single-crystal film designed by simulation offers a high frequency, larger, and high sensitivity, which provides application prospects in high-resolution and high-frequency medical ultrasonic imaging.
Due to their compact sizes, low power consumption levels, and convenient integration capabilities, piezoelectric micromachined ultrasonic transducers (PMUTs) have gained significant attention for enabling environmental sensing functionalities. However, the frequency inconsistency of the PMUT arrays often leads to directional errors with the ultrasonic beams. Herein, we propose a reconfigurable PMUT array based on a Sc0.2Al0.8N piezoelectric thin film for in-air ranging. Each element of the reconfigurable PMUT array possesses the ability to be independently replaced, enabling matching of the required frequency characteristics, which enhances the reusability of the device. The experimental results show that the frequency uniformity of the 2 × 2 PMUT array reaches 0.38% and the half-power beam width (θ−3dB) of the array measured at 20 cm is 60°. At a resonance of 69.7 kHz, the sound pressure output reaches 7.4 Pa (sound pressure level of 108.2 dB) at 19 mm, with a reception sensitivity of approximately 11.6 mV/Pa. Ultimately, the maximum sensing distance of the array is 7.9 m, and it extends to 14.1 m with a horn, with a signal-to-noise ratio (SNR) of 19.5 dB. This research significantly expands the ranging capability of PMUTs and showcases their great potential in environmental perception applications.