Interfraction anatomic deformations decrease the precision of radiotherapy, which can be improved by online adaptive radiation therapy (oART). However, oART takes time, allowing intrafractional deformations. In this study on focal radiotherapy for bladder cancer, we analyzed the time effect of oART on the equivalent uniform dose in the CTV (EUDCTV) per fraction and for the accumulated dose distribution over a treatment series as measure of effectiveness. A time-dependent digital CTV model was built from deformable image registration (DIR) between pre- and post-adaptation imaging. The model was highly dose fraction-specific. Planning target volume (PTV) margins were varied by shrinking the clinical PTV to obtain the margin-specific CTV. The EUDCTV per fraction decreased by—4.4 ± 0.9% of prescribed dose per min in treatment series with a steeper than average time dependency of EUDCTV. The EUDCTV for DIR-based accumulated dose distributions over a treatment series was significantly dependent on adaptation time and PTV margin (p < 0.0001, Chi2 test for each variable). Increasing adaptation times larger than 10 min by five minutes requires a 1.9 ± 0.24 mm additional margin to maintain EUDCTV for a treatment series. Adaptation time is an important determinant of the precision of oART for one half of the bladder cancer patients, and it should be aimed at to be minimized.
Online adaptive radiotherapy (ART) allows adaptation of the dose distribution to the anatomy captured by with pre-adaptation imaging. ART is time-consuming, and thus intra-fractional deformations can occur. This prospective registry study analyzed the effects of intra-fraction deformations of clinical target volume (CTV) on the equivalent uniform dose (EUDCTV) of focal bladder cancer radiotherapy. Using margins of 5–10 mm around CTV on pre-adaptation imaging, intra-fraction CTV-deformations found in a second imaging study reduced the 10th percentile of EUDCTV values per fraction from 101.1% to 63.2% of the prescribed dose. Dose accumulation across fractions of a series was determined with deformable-image registration and worst-case dose accumulation that maximizes the correlation of cold spots. A strong fractionation effect was demonstrated—the EUDCTV was above 95% and 92.5% as determined by the two abovementioned accumulation methods, respectively, for all series of dose fractions. A comparison of both methods showed that the fractionation effect caused the EUDCTV of a series to be insensitive to EUDCTV-declines per dose fraction, and this could be explained by the small size and spatial variations of cold spots. Therefore, ART for each dose fraction is unnecessary, and selective ART for fractions with large inter-fractional deformations alone is sufficient for maintaining a high EUDCTV for a radiotherapy series.
Introduction: The Acuros XB dose calculation algorithm implements advanced modelling of lateral electron transport, making dose distributions sensitive to density changes between source and subsequent CT. The aim of this study was to analyse the robustness of dose distribution in the central bronchial wall (CBW) of treatment plans from lung cancer patients treated with adaptive radiotherapy. Material and methods: IMRT or VMAT plans from patients with locally advanced lung cancer from a prospective registry cohort were analysed, who received definitive radiotherapy in surface-guided inspiratory breath-hold on the Ethos™ closed-bore linac, equipped with the HyperSight™ cone beam CT (CBCT). Dose homogeneity of the scheduled plans, optimized on planning CT (CTplan), was verified on the initial CBCT of a dose fraction (CBCT1). The adaptive plans were verified on a subsequent post-adaptation CBCT (CBCT2) of the same dose fraction. A predictive model was built for maximum dose (Dmax) in CBW in dependence on plan sensitivity in the central bronchial air lumen overlapping the planning target volume (CBALPTV) to water override (WOR) of the air lumen. Results: Ninety-one dose-fractions from 10 patients were analysed. Dmax values in the CBW of the scheduled plans showed over all significant inter-fractional increases from CTplan to subsequent CBCT1 (p < 0.0001, Wilcoxon test, stratified by patient) with significant heterogeneity between patients (p < 0.0001, Kruskal-Wallis Test). The median Dmax increase per dose fraction was 2.15% (-3.15 − 19.30%). Reducing the PTV overlap of scheduled plans with CBAL led to lower inter-fractional Dmax increases in CBW (p < 0.0001, signed rank test). Dose accumulation showed, that Dmax and D1cc values in CBW over the treatment course stayed in all patients below 110.5% and 107.5% and that the equivalent uniform dose in CTV around the CBW stayed > 95% for scheduled plans. A predictive model showed the dependence of inter-fractional Dmax increases in CBW of scheduled plans on an interaction between plan sensitivity on CTplan to WOR in CBALPTV and density change at the Dmax point in CBCT1 between CTplan and CBCT1 (p < 0.0001, t-test). Intra-fractional Dmax increases of adaptive plans in CBW amounted to only 20% +/- 1.1% of the inter-fractional increases of scheduled plans, as intra-fractional deformations were smaller than inter-fractional (p < 0.0001, signed rank test). Conclusion: Dose homogeneity in CBW of Ethos plans were found sufficiently robust against intra-fractional deformations during course of online adaptive radiotherapy. Plan sensitivity to anatomic changes can be detected and controlled on the planning CT by the WOR of air in CBALPTV.
13 April 2026 in Technical Innovations & Patient Support in Radiation Oncology
In this prospective cross-over study, the precision of manual correction of the clinical target volume (CTV) during online-adaptive radiotherapy (ART) of patients with bladder cancer was investigated in dependence on the input of applied computational algorithms. Online-adaptive-radiation therapy (ART) fractions were analysed from a prospective registry as a component of a trimodality treatment for bladder cancer. The CBCT-guided adaptive radiation therapy (CBCTgART) workflow uses a CBCT acquired at the beginning of a treatment session (CBCT1) to update the target volume contours of the planning CT (pCT) on the current anatomy of the day. The study comprises radiotherapy fractions with target (CTV) segments showing clinically relevant deviations (>5 mm) when mapped between pre-treatment (CBCT1) and post-adaptation (CBCT2) images. CTValgo1-2 were obtained from two deformable-image-registration algorithms (algo1, algo2) based on AI-generated normal-tissue contours and a rigid copy of the CTVoriginal termed CTValgo3 (algo3). Verification cone-beam-computed-tomography (CBCT2) acquired during ART showed CTValgo1-3 on new anatomical scenarios. The task of 13 physicians was to adjust CTValgo1-3 on CBCT2 to match the CTVoriginal on CBCT1. In 151/169 pairwise comparisons, mean-distance-of-segments-to-ground-truth (MDAGT) after adjustment by a physician was larger for the poorer algorithms than for the better ones. The binomial proportion was 0.893, significantly different from 0.5 as null proportion (p < 0.0001, exact-binomial-test), and not dependent on the physician or on the respective patient. In a quantitative analysis by a mixed-model, the MDAGT of the manually adjusted segments between 16% and 50% of the errors were on average corrected by the physicians, with interindividual differences (p < 0.0001,F-test). The present study results reveal that the quality of AI-generated contours is of crucial importance for a proper online onboard ART, as errors may bias clinical workflow and contouring. The accuracy of supervised structures strongly depends on the accuracy of the AI generated contours before supervision.
7 July 2026 in Journal of Applied Clinical Medical Physics
Background: In the online adaptive platform, a linear Boltzmann‐transport‐equation‐solver (LBTE) as calculation algorithm is implemented for dose optimization. This class‐C‐optimizer is known to counteract the dose decrease at boundaries of small fields due to electronic disequilibrium by increasing the fluence to achieve the goals of dose homogeneity within the PTV. Purpose: To analyze the dosimetric sensitivity of adaptive treatment plans for prostate cancer to intrafractional anatomic changes in the presence of rectal air using a CBCT‐based adaptive platform. Methods: In the first part of the study planning CT scans (CT plan ) from eight patients treated with an air‐filled endorectal balloon and two patients presenting larger rectal air pockets were included in a simulation study. The dataset was used to assess the sensitivity of LBTE‐optimized treatment plans to intrafractional density variations and to changes in the overlap between the planning target volume (PTV) and an air cavity (PTV∩Air structure). Density changes resulting from anatomical shifts were simulated using water overrides (WOR) in defined shift regions within the PTV∩Air structure. These shift regions were created by dorsally expanding the clinical target volume (CTV) by margins of 2 mm or 5 mm. Additionally, a WOR of the entire rectum was applied. For each WOR scenario, D max , D 1 and D 1cc values were recorded within the fixed PTV∩Air structure and within the rectal wall, which was shifted according to the applied margin. A mixed linear model was built to describe dosimetric characteristics in dependence of the WOR scenario. Additionally, intrafractional variations of D max within the PTV were assessed in 101 dose fractions from 15 patients who were treated with a rectal balloon and underwent online adaptive radiotherapy. All doses were normalized by the prescribed dose. Results: WOR within PTV∩Air‐structure overlap resulted in increases of the analyzed dosimetric characteristics. D 1cc increased with WOR within shift margins of 2 and 5 mm and within the entire rectal cavity by 2.2% ± 0.7%, 5.5% ± 0.7%, and 8.7% ± 1.0%, respectively ( p < 0.0001, F ‐test). The corresponding dose increases within the rectal wall were slightly smaller, with D 1cc increases of 1.4% ± 0.6%, 1.7% ± 0.9%, and 5.0% ± 0.5%. Sensitivity to WOR in the PTV∩Air using a 5 mm shift margin was markedly lower when the same treatment plans were recalculated with AAA compared with LBTE ( p = 0.0020, signed‐rank test). On average, AAA detected only 43% ± 12% of the WOR effect predicted by LBTE. For prostate cancer patients treated with a rectal balloon, D max , D 1 and D 1cc changes in LBTE‐optimized plans showed 90% confidence intervals of [−0.05–0.05] due to intrafractional motion, suggesting that posterior tissue shifts of 5 mm or less do not have a clinically relevant impact. Conclusions: PTV∩Air larger than 5 mm led to LBTE‐optimized treatment plans, that are sensitive to anatomic soft tissue shifts larger than 5 mm in posterior direction with respect to dose homogeneity. PTV∩Air‐overlaps up to 5 mm led to LBTE‐optimized treatment plans, that showed only minor sensitivities to anatomic soft tissue shifts of 2–5 mm in posterior direction with respect to dose homogeneity. During online adaptive radiotherapy, the presence of rectal air pockets or an air‐filled rectal balloon did not result in clinically relevant dose increases, provided that intrafractional motion–induced soft tissue shifts remained within 5 mm in the posterior direction.
Background/Objectives: Analysis of the density and spatial distribution of pulmonary infiltrates of patients with high-grade (≥3) pneumonitis after radiochemotherapy and durvalumab consolidation (RT/CTx + IO) was performed in order to define dosimetric hallmarks of the development of infiltrates following this multimodality treatment. Methods: Consecutive patients treated with RT/CTx + IO for stage III NSCLC were retrospectively reviewed with respect to the occurrence of grade ≥ 3 pneumonitis. Lung infiltrates were contoured on follow-up CT scans acquired around the time of maximum pneumonitis expression. The applied dose distribution was overlaid with the follow-up CT using elastic deformation, and infiltrates were binned according to their density in density strata of 50 HU. The dose and density dependence of partial infiltrate volumes per unit lung volume was analyzed using a mixed fixed and random effect model adjusting for patient, density and dose-dependent random effects. Results: Six patients with grade ≥ 3 pneumonitis were identified from 132 patients treated with RT/CT + IO at a comprehensive cancer center. Partial volumes of lung infiltrates captured by follow-up CT with maximum pneumonitis expression ranged from 15.5 to 60.0% (median 39.8%). A significant, systematic dose–response relationship was found for partial lung infiltrate volumes per dose and density bin. A unimodal density distribution of partial lung infiltrate volumes was also found over the infiltrate density range of −1000 to 100 HU. This was determined using a mixed model that adjusted for random effects (p < 0.0001 for both effects, F-test). There was no interaction effect between systematic dose and infiltrate density dependence of the partial infiltrate volumes. The proportion of infiltrate volumes that are attributable to the systematic dose–response relation amounts to a mean of 16.6% of the total infiltrate volume per patient according to this model. Compared to patients with pneumonitis of grade ≤ 2, patients with high-risk pneumonitis had higher partial infiltrate volumes, particularly in the low-dose regions in five grade dose bins up to 20 Gy (AUC = 1.0, p < 0.0001, likelihood-ratio test). Conclusions: Dose-dependent and -independent partial lung infiltrate volumes were found in patients with high-grade pneumonitis after RT/CTx + IO. These results indicate that pneumonitis involves contributions from both radiochemotherapy-induced and immunotherapy-related mechanisms.