The aim of this study is to examine the precision of semi-automatic, conventional and automatic volumetry tools for pulmonary nodules in chest CT with phantom N1 LUNGMAN. The phantom is a life-size anatomical chest model with pulmonary nodules representing solid and subsolid metastases. Gross tumor volumes (GTVis) were contoured using various approaches: manually (0); as a means of semi-automated, conventional contouring with (I) adaptive-brush function; (II) flood-fill function; and (III) image-thresholding function. Furthermore, a deep-learning algorithm for automatic contouring was applied (IV). An intermodality comparison of the above-mentioned strategies for contouring GTVis was performed. For the mean GTVref (standard deviation (SD)), the interquartile range (IQR)) was 0.68 mL (0.33; 0.34–1.1). GTV segmentation was distributed as follows: (I) 0.61 mL (0.27; 0.36–0.92); (II) 0.41 mL (0.28; 0.23–0.63); (III) 0.65 mL (0.35; 0.32–0.90); and (IV) 0.61 mL (0.29; 0.33–0.95). GTVref was found to be significantly correlated with GTVis (I) p < 0.001, r = 0.989 (III) p = 0.001, r = 0.916, and (IV) p < 0.001, r = 0.986, but not with (II) p = 0.091, r = 0.595. The Sørensen–Dice indices for the semi-automatic tools were 0.74 (I), 0.57 (II) and 0.71 (III). For the semi-automatic, conventional segmentation tools evaluated, the adaptive-brush function (I) performed closest to the reference standard (0). The automatic deep learning tool (IV) showed high performance for auto-segmentation and was close to the reference standard. For high precision radiation therapy, visual control, and, where necessary, manual correction, are mandatory for all evaluated tools.
13 April 2026 in Technical Innovations & Patient Support in Radiation Oncology
In this prospective cross-over study, the precision of manual correction of the clinical target volume (CTV) during online-adaptive radiotherapy (ART) of patients with bladder cancer was investigated in dependence on the input of applied computational algorithms. Online-adaptive-radiation therapy (ART) fractions were analysed from a prospective registry as a component of a trimodality treatment for bladder cancer. The CBCT-guided adaptive radiation therapy (CBCTgART) workflow uses a CBCT acquired at the beginning of a treatment session (CBCT1) to update the target volume contours of the planning CT (pCT) on the current anatomy of the day. The study comprises radiotherapy fractions with target (CTV) segments showing clinically relevant deviations (>5 mm) when mapped between pre-treatment (CBCT1) and post-adaptation (CBCT2) images. CTValgo1-2 were obtained from two deformable-image-registration algorithms (algo1, algo2) based on AI-generated normal-tissue contours and a rigid copy of the CTVoriginal termed CTValgo3 (algo3). Verification cone-beam-computed-tomography (CBCT2) acquired during ART showed CTValgo1-3 on new anatomical scenarios. The task of 13 physicians was to adjust CTValgo1-3 on CBCT2 to match the CTVoriginal on CBCT1. In 151/169 pairwise comparisons, mean-distance-of-segments-to-ground-truth (MDAGT) after adjustment by a physician was larger for the poorer algorithms than for the better ones. The binomial proportion was 0.893, significantly different from 0.5 as null proportion (p < 0.0001, exact-binomial-test), and not dependent on the physician or on the respective patient. In a quantitative analysis by a mixed-model, the MDAGT of the manually adjusted segments between 16% and 50% of the errors were on average corrected by the physicians, with interindividual differences (p < 0.0001,F-test). The present study results reveal that the quality of AI-generated contours is of crucial importance for a proper online onboard ART, as errors may bias clinical workflow and contouring. The accuracy of supervised structures strongly depends on the accuracy of the AI generated contours before supervision.
Background/Objectives: Analysis of the density and spatial distribution of pulmonary infiltrates of patients with high-grade (≥3) pneumonitis after radiochemotherapy and durvalumab consolidation (RT/CTx + IO) was performed in order to define dosimetric hallmarks of the development of infiltrates following this multimodality treatment. Methods: Consecutive patients treated with RT/CTx + IO for stage III NSCLC were retrospectively reviewed with respect to the occurrence of grade ≥ 3 pneumonitis. Lung infiltrates were contoured on follow-up CT scans acquired around the time of maximum pneumonitis expression. The applied dose distribution was overlaid with the follow-up CT using elastic deformation, and infiltrates were binned according to their density in density strata of 50 HU. The dose and density dependence of partial infiltrate volumes per unit lung volume was analyzed using a mixed fixed and random effect model adjusting for patient, density and dose-dependent random effects. Results: Six patients with grade ≥ 3 pneumonitis were identified from 132 patients treated with RT/CT + IO at a comprehensive cancer center. Partial volumes of lung infiltrates captured by follow-up CT with maximum pneumonitis expression ranged from 15.5 to 60.0% (median 39.8%). A significant, systematic dose–response relationship was found for partial lung infiltrate volumes per dose and density bin. A unimodal density distribution of partial lung infiltrate volumes was also found over the infiltrate density range of −1000 to 100 HU. This was determined using a mixed model that adjusted for random effects (p < 0.0001 for both effects, F-test). There was no interaction effect between systematic dose and infiltrate density dependence of the partial infiltrate volumes. The proportion of infiltrate volumes that are attributable to the systematic dose–response relation amounts to a mean of 16.6% of the total infiltrate volume per patient according to this model. Compared to patients with pneumonitis of grade ≤ 2, patients with high-risk pneumonitis had higher partial infiltrate volumes, particularly in the low-dose regions in five grade dose bins up to 20 Gy (AUC = 1.0, p < 0.0001, likelihood-ratio test). Conclusions: Dose-dependent and -independent partial lung infiltrate volumes were found in patients with high-grade pneumonitis after RT/CTx + IO. These results indicate that pneumonitis involves contributions from both radiochemotherapy-induced and immunotherapy-related mechanisms.