peng gao

Dr. peng gao


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
HPHuangsheng Pu
Huangsheng Pu
PGpeng gao
peng gao
YLYang Liu
Yang Liu
JRJunyan Rong
Junyan Rong
FSFeng Shi
Feng Shi
HLHongbing Lu
Hongbing Lu
Cone beam X-ray luminescence computed tomography (CB-XLCT) is a promising imaging technique in studying the physiological and pathological processes in small animals. However, the dynamic bio-distributions of probes in small animal especially in adjacent targets are still hard to be captured directly from dynamic CB-XLCT. In this work, a 4D temporal-spatial reconstruction method based on principal component analysis (PCA) in the projection space is proposed for dynamic CB-XLCT. Firstly, projections of angles in each 3D frame are compressed to reduce the noises initially. Then a temporal PCA is performed on the projection data to decorrelate the 4D problem into separate 3D problems in the PCA domain. In the PCA domain, the difference between dynamic behaviors of multiple targets can be reflected by the first several principal components which can be further used for fast and improved reconstruction by a restarted Tikhonov regularization method. At last, by discarding the principal components mainly reflecting noise, the concentration series of targets are recovered from the first few reconstruction results with a mask as the constraint. Numerical simulation and phantom experiment demonstrate that the proposed method can resolve multiple targets and recover the dynamic distributions with high computation efficiency. The proposed method provides a new feasibility for imaging dynamic bio-distributions of probes in vivo.

22 January 2020 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
PGpeng gao
peng gao
JRJunyan Rong
Junyan Rong
TLTianshuai Liu
Tianshuai Liu
WZWenli zhang
Wenli zhang
BLBin Lan
Bin Lan
HLHongbing Lu
Hongbing Lu
X-ray luminescence computed tomography (XLCT) has attracted much attention as a CT/optical dual-mode imaging technique.1 – 3 It utilizes x-ray excitable nanophosphors as biomarkers to produce visible or near-infrared (NIR) light upon x-ray irritation and naturally combines x-ray structure imaging of high resolution with optical molecular imaging of high sensitivity and specificity. Compared with traditional optical molecular imaging modalities, such as fluorescence molecular tomography (FMT)4,5 and bioluminescence tomography (BLT),6,7 XLCT can detect targets deeply seated in the imaging object with the use of x-rays and provides higher sensitivity due to the avoidance of background optical signals and autofluorescence. With the above advantages, great efforts have been devoted to XLCT imaging and several types of XLCT systems have been proposed according to the x-ray beam shapes. Narrow-beam2,3 and pencil-beam XLCT8,9 can achieve high spatial resolution, but the long imaging time hinders their application to fast biomedical applications. To reduce imaging time, cone-beam XLCT (CB-XLCT) systems10 – 13 have been proposed for fast imaging to skip the translation step essential in narrow- and pencil-beam XLCT systems.

26 January 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
PGpeng gao
peng gao
HPHuangsheng Pu
Huangsheng Pu
TLTianshuai Liu
Tianshuai Liu
YCYilin Cao
Yilin Cao
WLWangyang Li
Wangyang Li
JRJunyan Rong
Junyan Rong
Single-view cone-beam X-ray luminescence computed tomography (CB-XLCT) has recently gained attention as a highly promising imaging technique that allows for the efficient and rapid three-dimensional visualization of nanophosphor (NP) distributions in small animals. However, the reconstruction performance is hindered by the ill-posed nature of the inverse problem and the effects of depth variation as only a single view is acquired. To tackle this issue, we present a methodology that integrates an automated restarting strategy with depth compensation to achieve reconstruction. The present study employs a fast proximal gradient descent (FPGD) method, incorporating L0 norm regularization, to achieve efficient reconstruction with accelerated convergence. The proposed approach offers the benefit of retrieving neighboring multitarget distributions without the need for CT priors. Additionally, the automated restarting strategy ensures reliable reconstructions without the need for manual intervention. Numerical simulations and physical phantom experiments were conducted using a custom CB-XLCT system to demonstrate the accuracy of the proposed method in resolving adjacent NPs. The results showed that this method had the lowest relative error compared to other few-view techniques. This study signifies a significant progression in the development of practical single-view CB-XLCT for high-resolution 3−D biomedical imaging.

28 August 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
TLTianshuai Liu
Tianshuai Liu
SHShien Huang
Shien Huang
RLRuijing Li
Ruijing Li
PGpeng gao
peng gao
WLWangyang Li
Wangyang Li
JRJunyan Rong
Junyan Rong
Background and Objective: Emerging as a hybrid imaging modality, cone-beam X-ray luminescence computed tomography (CB-XLCT) has been developed using X-ray-excitable nanoparticles. In contrast to conventional bio-optical imaging techniques like bioluminescence tomography (BLT) and fluorescence molecular tomography (FMT), CB-XLCT offers the advantage of greater imaging depth while significantly reducing interference from autofluorescence and background fluorescence, owing to its utilization of X-ray-excited nanoparticles. However, due to the intricate excitation process and extensive light scattering within biological tissues, the inverse problem of CB-XLCT is fundamentally ill-conditioned. Methods: An end-to-end three-dimensional deep encoder-decoder network, termed DeepCB-XLCT, is introduced to improve the quality of CB-XLCT reconstructions. This network directly establishes a nonlinear mapping between the distribution of internal X-ray-excitable nanoparticles and the corresponding boundary fluorescent signals. To improve the fidelity of target shape restoration, the structural similarity loss (SSIM) was incorporated into the objective function of the DeepCB-XLCT network. Additionally, a loss term specifically for target regions was introduced to improve the network’s emphasis on the areas of interest. As a result, the inaccuracies in reconstruction caused by the simplified linear model used in conventional methods can be effectively minimized by the proposed DeepCB-XLCT method. Results and Conclusions: Numerical simulations, phantom experiments, and in vivo experiments with two targets were performed, revealing that the DeepCB-XLCT network enhances reconstruction accuracy regarding contrast-to-noise ratio and shape similarity when compared to traditional methods. In addition, the findings from the XLCT tomographic images involving three targets demonstrate its potential for multi-target CB-XLCT imaging.

10 March 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
WLWangyang Li
Wangyang Li
PGpeng gao
peng gao
RLRuijing Li
Ruijing Li
TLTianshuai Liu
Tianshuai Liu
ZWZhongfei Wang
Zhongfei Wang
JRJunyan Rong
Junyan Rong
Context: X-ray-induced photodynamic therapy (X-PDT) is an emerging modality for deep-tumor treatment, leveraging radiosensitizing nanoprobes to enhance therapeutic effects. Problem: However, the efficacy of X-PDT is critically dependent on the incident X-ray energy, and the selection of an optimal spectrum remains a significant clinical challenge. Motivation: A systematic approach to optimizing X-ray energy is crucial for maximizing dose enhancement and translating X-PDT’s potential into effective clinical outcomes. Aim: This study therefore aims to identify the optimal X-ray energy for X-PDT by systematically evaluating the dose enhancement provided by nanoprobes across a range of clinically relevant energies. Proposed Methodology: We developed a Geant4-based Monte Carlo model to simulate the absorbed dose in a tumor phantom, both with and without X-PDT nanoprobes, under various X-ray energies (20–160 kVp). The dose enhancement ratio (DER) was calculated to quantify the sensitization effect. To validate our model, the simulated dose data were directly correlated with in vivo experimental tumor growth inhibition (TGI) rates. Main Results: The absorbed dose peaks at shallow depths (<1.0 mm), and the 60 kVp X-ray beam yielded the highest peak dose and the maximum DER. Furthermore, the absorbed dose calculated in the model incorporating nanoprobes showed a stronger correlation with experimental TGI than the model without them, confirming the simulation’s predictive value. Conclusions: There is an optimized X-ray excitation energy value for maximizing the therapeutic effect for X-PDT. The simulation method provides a potential way to optimize the treatment protocols for X-PDT. But accurate simulation needs to be carried out in combination with more biological modeling.