The Journal of Biomedical Optics (JBO) publishes peer-reviewed papers on the use of novel optical systems and techniques for improved health care and biomedical research.
15 May 2019 in IEEE Transactions on Medical Imaging
Cone beam X-ray luminescence computed tomography (CB-XLCT) is a promising imaging technique in studying the physiological and pathological processes in small animals. However, the dynamic bio-distributions of probes in small animal especially in adjacent targets are still hard to be captured directly from dynamic CB-XLCT. In this work, a 4D temporal-spatial reconstruction method based on principal component analysis (PCA) in the projection space is proposed for dynamic CB-XLCT. Firstly, projections of angles in each 3D frame are compressed to reduce the noises initially. Then a temporal PCA is performed on the projection data to decorrelate the 4D problem into separate 3D problems in the PCA domain. In the PCA domain, the difference between dynamic behaviors of multiple targets can be reflected by the first several principal components which can be further used for fast and improved reconstruction by a restarted Tikhonov regularization method. At last, by discarding the principal components mainly reflecting noise, the concentration series of targets are recovered from the first few reconstruction results with a mask as the constraint. Numerical simulation and phantom experiment demonstrate that the proposed method can resolve multiple targets and recover the dynamic distributions with high computation efficiency. The proposed method provides a new feasibility for imaging dynamic bio-distributions of probes in vivo.
X-ray luminescence computed tomography (XLCT) has attracted much attention as a CT/optical dual-mode imaging technique.1–3 It utilizes x-ray excitable nanophosphors as biomarkers to produce visible or near-infrared (NIR) light upon x-ray irritation and naturally combines x-ray structure imaging of high resolution with optical molecular imaging of high sensitivity and specificity. Compared with traditional optical molecular imaging modalities, such as fluorescence molecular tomography (FMT)4,5 and bioluminescence tomography (BLT),6,7 XLCT can detect targets deeply seated in the imaging object with the use of x-rays and provides higher sensitivity due to the avoidance of background optical signals and autofluorescence. With the above advantages, great efforts have been devoted to XLCT imaging and several types of XLCT systems have been proposed according to the x-ray beam shapes. Narrow-beam2,3 and pencil-beam XLCT8,9 can achieve high spatial resolution, but the long imaging time hinders their application to fast biomedical applications. To reduce imaging time, cone-beam XLCT (CB-XLCT) systems10–13 have been proposed for fast imaging to skip the translation step essential in narrow- and pencil-beam XLCT systems.
Single-view cone-beam X-ray luminescence computed tomography (CB-XLCT) has recently gained attention as a highly promising imaging technique that allows for the efficient and rapid three-dimensional visualization of nanophosphor (NP) distributions in small animals. However, the reconstruction performance is hindered by the ill-posed nature of the inverse problem and the effects of depth variation as only a single view is acquired. To tackle this issue, we present a methodology that integrates an automated restarting strategy with depth compensation to achieve reconstruction. The present study employs a fast proximal gradient descent (FPGD) method, incorporating L0 norm regularization, to achieve efficient reconstruction with accelerated convergence. The proposed approach offers the benefit of retrieving neighboring multitarget distributions without the need for CT priors. Additionally, the automated restarting strategy ensures reliable reconstructions without the need for manual intervention. Numerical simulations and physical phantom experiments were conducted using a custom CB-XLCT system to demonstrate the accuracy of the proposed method in resolving adjacent NPs. The results showed that this method had the lowest relative error compared to other few-view techniques. This study signifies a significant progression in the development of practical single-view CB-XLCT for high-resolution 3−D biomedical imaging.
Background and Objective: Emerging as a hybrid imaging modality, cone-beam X-ray luminescence computed tomography (CB-XLCT) has been developed using X-ray-excitable nanoparticles. In contrast to conventional bio-optical imaging techniques like bioluminescence tomography (BLT) and fluorescence molecular tomography (FMT), CB-XLCT offers the advantage of greater imaging depth while significantly reducing interference from autofluorescence and background fluorescence, owing to its utilization of X-ray-excited nanoparticles. However, due to the intricate excitation process and extensive light scattering within biological tissues, the inverse problem of CB-XLCT is fundamentally ill-conditioned. Methods: An end-to-end three-dimensional deep encoder-decoder network, termed DeepCB-XLCT, is introduced to improve the quality of CB-XLCT reconstructions. This network directly establishes a nonlinear mapping between the distribution of internal X-ray-excitable nanoparticles and the corresponding boundary fluorescent signals. To improve the fidelity of target shape restoration, the structural similarity loss (SSIM) was incorporated into the objective function of the DeepCB-XLCT network. Additionally, a loss term specifically for target regions was introduced to improve the network’s emphasis on the areas of interest. As a result, the inaccuracies in reconstruction caused by the simplified linear model used in conventional methods can be effectively minimized by the proposed DeepCB-XLCT method. Results and Conclusions: Numerical simulations, phantom experiments, and in vivo experiments with two targets were performed, revealing that the DeepCB-XLCT network enhances reconstruction accuracy regarding contrast-to-noise ratio and shape similarity when compared to traditional methods. In addition, the findings from the XLCT tomographic images involving three targets demonstrate its potential for multi-target CB-XLCT imaging.
As an emerging hybrid imaging modality, cone-beam X-ray luminescence computed tomography (CB-XLCT) has been proposed based on the development of X-ray excitable nanoparticles. Fast three-dimensional (3-D) CB-XLCT imaging has attracted significant attention for the application of XLCT in fast dynamic imaging study. Currently, due to the short data collection time, single-view CB-XLCT imaging achieves fast resolving the three-dimensional (3-D) distribution of X-ray-excitable nanoparticles. However, owing to only one angle projection data is used in the reconstruction, the single-view CB-XLCT inverse problem is inherently ill-conditioned, which makes image reconstruction highly susceptible to the effects of noise and numerical errors. To solve the ill-posed inverse problem, using the sparseness of the X-ray-excitable nanoparticles distribution as the prior, a new reconstruction approach based on total variance is proposed in this study. To evaluate the performance of the proposed approach, a phantom experiment was performed based on a CB-XLCT imaging system. The experiments indicate that the reconstruction from single-view XCLT can provide satisfactory results based on the proposed approach. In conclusion, with the reconstruction approach based on total variance, we implement a fast XLCT reconstruction of high quality with only one angle projection data used, which would be helpful for fast dynamic imaging study. In future, we will focus on how to applying the proposed TV-based reconstruction method and CB-XLCT imaging system to image fast biological distributions of the X-ray excitable nanophosphors in vivo.