Context: X-ray-induced photodynamic therapy (X-PDT) is an emerging modality for deep-tumor treatment, leveraging radiosensitizing nanoprobes to enhance therapeutic effects. Problem: However, the efficacy of X-PDT is critically dependent on the incident X-ray energy, and the selection of an optimal spectrum remains a significant clinical challenge. Motivation: A systematic approach to optimizing X-ray energy is crucial for maximizing dose enhancement and translating X-PDT’s potential into effective clinical outcomes. Aim: This study therefore aims to identify the optimal X-ray energy for X-PDT by systematically evaluating the dose enhancement provided by nanoprobes across a range of clinically relevant energies. Proposed Methodology: We developed a Geant4-based Monte Carlo model to simulate the absorbed dose in a tumor phantom, both with and without X-PDT nanoprobes, under various X-ray energies (20–160 kVp). The dose enhancement ratio (DER) was calculated to quantify the sensitization effect. To validate our model, the simulated dose data were directly correlated with in vivo experimental tumor growth inhibition (TGI) rates. Main Results: The absorbed dose peaks at shallow depths (<1.0 mm), and the 60 kVp X-ray beam yielded the highest peak dose and the maximum DER. Furthermore, the absorbed dose calculated in the model incorporating nanoprobes showed a stronger correlation with experimental TGI than the model without them, confirming the simulation’s predictive value. Conclusions: There is an optimized X-ray excitation energy value for maximizing the therapeutic effect for X-PDT. The simulation method provides a potential way to optimize the treatment protocols for X-PDT. But accurate simulation needs to be carried out in combination with more biological modeling.
Background and Objective: Emerging as a hybrid imaging modality, cone-beam X-ray luminescence computed tomography (CB-XLCT) has been developed using X-ray-excitable nanoparticles. In contrast to conventional bio-optical imaging techniques like bioluminescence tomography (BLT) and fluorescence molecular tomography (FMT), CB-XLCT offers the advantage of greater imaging depth while significantly reducing interference from autofluorescence and background fluorescence, owing to its utilization of X-ray-excited nanoparticles. However, due to the intricate excitation process and extensive light scattering within biological tissues, the inverse problem of CB-XLCT is fundamentally ill-conditioned. Methods: An end-to-end three-dimensional deep encoder-decoder network, termed DeepCB-XLCT, is introduced to improve the quality of CB-XLCT reconstructions. This network directly establishes a nonlinear mapping between the distribution of internal X-ray-excitable nanoparticles and the corresponding boundary fluorescent signals. To improve the fidelity of target shape restoration, the structural similarity loss (SSIM) was incorporated into the objective function of the DeepCB-XLCT network. Additionally, a loss term specifically for target regions was introduced to improve the network’s emphasis on the areas of interest. As a result, the inaccuracies in reconstruction caused by the simplified linear model used in conventional methods can be effectively minimized by the proposed DeepCB-XLCT method. Results and Conclusions: Numerical simulations, phantom experiments, and in vivo experiments with two targets were performed, revealing that the DeepCB-XLCT network enhances reconstruction accuracy regarding contrast-to-noise ratio and shape similarity when compared to traditional methods. In addition, the findings from the XLCT tomographic images involving three targets demonstrate its potential for multi-target CB-XLCT imaging.
Single-view cone-beam X-ray luminescence computed tomography (CB-XLCT) has recently gained attention as a highly promising imaging technique that allows for the efficient and rapid three-dimensional visualization of nanophosphor (NP) distributions in small animals. However, the reconstruction performance is hindered by the ill-posed nature of the inverse problem and the effects of depth variation as only a single view is acquired. To tackle this issue, we present a methodology that integrates an automated restarting strategy with depth compensation to achieve reconstruction. The present study employs a fast proximal gradient descent (FPGD) method, incorporating L0 norm regularization, to achieve efficient reconstruction with accelerated convergence. The proposed approach offers the benefit of retrieving neighboring multitarget distributions without the need for CT priors. Additionally, the automated restarting strategy ensures reliable reconstructions without the need for manual intervention. Numerical simulations and physical phantom experiments were conducted using a custom CB-XLCT system to demonstrate the accuracy of the proposed method in resolving adjacent NPs. The results showed that this method had the lowest relative error compared to other few-view techniques. This study signifies a significant progression in the development of practical single-view CB-XLCT for high-resolution 3−D biomedical imaging.