A feasibility study of a magnetohydrodynamic (MHD) ship using no-insulation (NI) high-temperature superconductor (HTS) magnets made of rare earth barium cobalt oxide (REBCO) tape is presented. Based on the preliminary design, fabrication, and experimental results of a miniature MHD ship with NI HTS magnets in a liquid nitrogen environment (77 K), a scale-up design of a full-size MHD ship with REBCO NI HTS magnets at 20 K is presented. The final velocity of the miniature MHD ship is measured to be 4.0 cm/s, which represents 41.7% of the theoretically calculated velocity. Since the applicability of REBCO NI HTS magnets to MHD propulsion is confirmed, a scale-up design of their application to Yamato-1, the first MHD ship with low-temperature superconductor magnets (LTS), is presented. The operating parameters when the designed magnets are applied are compared with those of Yamato-1. Based on the same geometry, it is demonstrated that the application of NI HTS magnets at 20 K can improve the central magnetic field and propulsive Lorentz force by about 3 times compared to the Yamato-1 operated at 4 K.
Aiming at an intelligent point-of-care imaging technology for rheumatology clinics, a fully automatic 3D photoacoustic (PA) and ultrasound (US) dual-modality system driven by a robot and powered by deep learning (DL)-based image processing was developed. Automated scanning of volumetric images from patient joints, plus DL-based tissue segmentation and quantification of imaging biomarkers, ensures that the measurements from this system are objective and reproducible. Clinical validation was conducted via a longitudinal study on 43 finger joints from patients affected by inflammatory arthritis. Using manual segmentations as the gold standard, our DL algorithm utilizing the 3D Deep Attentive Feature (DAF3D) model showed satisfactory performance in automatic segmentation of joint space and synovial region and achieved a Dice score of 0.77±0.03 and an IoU of 0.64±0.03. Based on the tissue segmentations facilitated by the DAF3D model, six volumetric imaging biomarkers reflecting the activity of arthritis and its change in response to the treatment were quantified, including hyperemia, blood oxygenation, US power Doppler, joint space echogenicity, joint space volume, and synovial volume. The imaging biomarkers quantified from DL-based segmentation and manual segmentation showed moderate to strong correlations (: 0.41−0.86). Hyperemia quantified from PA imaging has the strongest association with the disease activity indicated by Clinical Assessment Questionnaire (CAQ) scores, with =0.41. Linear models combining the two biomarkers from PA imaging, the four biomarkers from US imaging, and all six imaging biomarkers rendered moderate to very strong associations with the disease activity scores, with of 0.41, 0.26, and 0.52, respectively.
SignificanceOptical coherence tomography (OCT) systems are traditionally decomposed into engine and scanner components with an expensive and noise-prone analog interface to communicate the scan pattern between the two. Although simple and convenient, analog signals are susceptible to interference and require expensive hardware to generate with appropriate precision for OCT.AimTo overcome these limitations, we implemented a digital interface for our OCT system using low-cost embedded microprocessors and custom PC software, exploiting recent trends toward digital servo drivers for optical scanning.ApproachOur interface features USB interfacing with a PC for scan pattern download and position feedback upload, 50-kHz communication rate, external triggers with adjustable downsampling, and no external power requirements.ResultsWe quantitatively assessed the latency, noise characteristics, and imaging performance of our digital interface in comparison with a conventional analog system that is an order of magnitude more expensive. The signal analysis confirmed that the digital interface reliably transmitted the intended scan pattern to the galvanometer driver and significantly reduced noise in the position feedback signal. High-speed laser trajectory tracking during sparse raster scanning revealed that discrepancies in the analog feedback signal did not reflect actual galvanometer positioning errors; both interfaces achieved equivalent spatial accuracy. Resolution testing demonstrated that both interfaces produced comparable OCT image quality, with no discernible difference up to the system’s resolution limit, whereas reconstruction based on digital interface position feedback outperformed other methods when demanding scan patterns, such as spiral scanning, were applied. To support reproducibility and system integration, we developed a custom printed circuit board (PCB), enabling a compact and robust configuration for future OCT deployments. A simplified version of the firmware is supported by our open-source library vortex.ConclusionsTogether, these results demonstrate quantitative and qualitative equivalence of the interfaces, despite an order of magnitude reduction in cost. We released open-source software, PCB schematics, design files, and a bill of materials so that the OCT community can benefit from these improvements and cost savings.