Csilla Páger

Dr. Csilla Páger

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2024 in Molecules
Verified
Journal Article
Open access
PDF file
IPIva Pukleš
Iva Pukleš
CPCsilla Páger
Csilla Páger
Nikola SakačNikola Sakač
Nikola Sakač
BSBojan Sarkanj
Bojan Sarkanj
DMDean Marković
Dean Marković
M(Marija Jozanović (Horvat)
Marija Jozanović (Horvat)
Amino acids (AAs) have broad nutritional, therapeutic, and medical significance and thus are one of the most common active ingredients of nutritional supplements. Analytical strategies for determining AAs are high-priced and often limited to methods that require modification of AA polarity or incorporation of an aromatic moiety. The aim of this work was to develop a new method for the determination of L-arginine, L-ornithine, and L-lysine on low-cost microchip electrophoresis instrumentation conjugated with capacitively coupled contactless conductivity detection. A solution consisting of 0.3 M acetic acid and 1 × 10−5 M iminodiacetic acid has been identified as the optimal background electrolyte, ensuring the shortest possible analysis time. The short migration times of amino acids (t ≤ 64 s) and method simplicity resulted in high analysis throughput with high precision and linearity (R2≥ 0.9971). The limit of detection values ranged from 0.15 to 0.19 × 10−6 M. The accuracy of the proposed method was confirmed by recovery measurements. The results were compared with CE-UV-VIS and HPLC-DAD methods and showed good agreement. This work represents the first successful demonstration of the ME-C4D analysis of L-arginine, L-ornithine, and L-lysine in real samples.

Verified
Journal Article
Open access
PDF file
IPIva Pukleš
Iva Pukleš
CPCsilla Páger
Csilla Páger
Nikola SakačNikola Sakač
Nikola Sakač
BSBojan Sarkanj
Bojan Sarkanj
Brunislav MatasovićBrunislav Matasović
Brunislav Matasović
M(Marija Jozanović (Horvat)
Marija Jozanović (Horvat)
The health supplement industry is one of the fastest growing industries in the world, but there is a lack of suitable analytical methods for the determination of active compounds in health supplements such as peptides. The present work describes an implementation of contactless conductivity detection on microchip technology as a new strategy for the electrophoretic determination of L-carnosine in complex health supplement formulations without pre-concentration and derivatization steps. The best results were obtained in the case of +1.00 kV applied for 20 s for injection and +2.75 kV applied for 260 s for the separation step. Under the selected conditions, a linear detector response of 5 × 10−6 to 5 × 10−5 M was achieved. L-carnosine retention time was 61 s. The excellent reproducibility of both migration time and detector response confirmed the high precision of the method. The applicability of the method was demonstrated by the determination of L-carnosine in three different samples of health supplements. The recoveries ranged from 91 to 105%. Subsequent analysis of the samples by CE-UV-VIS and HPLC-DAD confirmed the accuracy of the obtained results.

18 September 2023 in Molecules
Verified
Journal Article
Open access
PDF file
FBFruzsina Balogh-Hartmann
Fruzsina Balogh-Hartmann
CPCsilla Páger
Csilla Páger
ABAnita Bufa
Anita Bufa
IHIbolya Madarászné Horváth
Ibolya Madarászné Horváth
ZVZsofia Verzar
Zsofia Verzar
LMLilla Makszin
Lilla Makszin
The widespread consumption of plant-based drinks, driven by health and dietary reasons (including cow’s milk allergy, lactose intolerance, milk protein intolerance, following a vegetarian or vegan diet) necessitates automated and accurate test methods. Our study demonstrates the simultaneous determination of protein components and total protein concentrations in plant-based milk alternatives using a rapid and reproducible microchip gel electrophoretic method. As expected, the electrophoretic profiles of each plant-based drink differed. Based on our analyses and statistical evaluation, it can be determined that the protein profiles of different plant-based beverages do not differ significantly between different manufacturers or different expiry dates. The measured total protein content was compared with the nominal values, i.e., the values stated on the beverage labels. As the number of consumers of functional and specialized plant-based milk alternatives continues to rise, it is important to prioritize methods that provide qualitative and quantitative information on protein composition and other nutrients.

26 March 2021 in Separations
Verified
Journal Article
Open access
PDF file
EMEmerencia Mező
Emerencia Mező
ABAnita Bufa
Anita Bufa
CPCsilla Páger
Csilla Páger
VPViktória Poór
Viktória Poór
Tamas MarosvölgyiTamas Marosvölgyi
Tamas Marosvölgyi
LMLilla Makszin
Lilla Makszin
Knowledge of the type and level of saturated and unsaturated fatty acids in food and clinical matrices is of practical importance, but the wide variety of fatty acids makes analyses very complex. The discrimination of the geometric isomers of fatty acid needs proper and effective separation conditions. The efficiency of three different stationary phases was evaluated by GC–MS methods in the separation of fatty acids in their methyl ester forms. Significant differences were observed in the efficiencies of polysiloxane-based (non-polar HP-5MS and medium/high polarity DB-225MS) and ionic liquid-based (SLB-IL111) columns. Baseline separation of the geometric isomers of linoleic acid methyl ester was obtained by the extremely polar SLB-IL111 column, showing a preference over the other two columns. The optimization of the experimental conditions (response linearity, limit of detection, limit of quantification, system suitability, intraday and interday repeatability and accuracy) showed the separation power of the ionic liquid interaction in the analyses by using short (25–30 m long) columns. By deducting the general principles of the interaction, predictions can be made for the separation of other isomers. The results facilitate the precise identification of various types of fatty acids in real samples for nutritional information.

22 June 2017 in Journal of Medical Case Reports
Verified
Journal Article
Open access
PDF file
ABAnita Bufa
Anita Bufa
NFNelli Farkas
Nelli Farkas
ZPZsolt Preisz
Zsolt Preisz
VPViktória Poór
Viktória Poór
CPCsilla Páger
Csilla Páger
PGPéter Miklós Gőcze
Péter Miklós Gőcze
Granulosa cell tumor of the ovary is the most frequent sex cord stromal tumor and represents 2 to 5% of all primary ovarian cancers. Ovarian granulosa cell tumor is a malignant tumor with slow progression and in some cases this tumor is hormonally active. The recurrence of granulosa cell tumor often happens after 5 years. We describe two cases of postmenopausal women with adult-type granulosa cell tumors of the ovary. Patient 1 is a 49-year-old European woman with a recurrent tumor; patient 2 is a 55-year-old European woman without recurrence of tumor. Urinary steroid profiles of patient 1 were monitored during a 5-year period starting from before an operation (13 samples). In patient 2, the urinary steroid profiles were monitored during a 3-year period starting from after an operation (six samples). The 24-hour urinary samples were examined and the urinary concentration of 20 androgen, progesterone, and corticoid metabolites was quantitatively determined by gas chromatography-mass spectrometry with selected ion-monitoring mode. Based on these cases a correlation could be observed between increased levels of the urinary steroids and the recurrence of ovarian granulosa cell tumor; therefore, we concluded that a urinary steroid profile could be a more effective method to follow-up such patients compared to the traditional serum hormones determinations supplemented with conventional tumor markers.

24 July 2024 in Foods
Verified
Journal Article
Open access
PDF file
FBFruzsina Balogh-Hartmann
Fruzsina Balogh-Hartmann
CPCsilla Páger
Csilla Páger
ABAnita Bufa
Anita Bufa
ZSZoltán Sipos
Zoltán Sipos
ADAnna Dávidovics
Anna Dávidovics
LMLilla Makszin
Lilla Makszin
The growing consumption of plant-based milk substitutes raises important questions about their composition. The various additives used by manufacturers, including those employed as flavor enhancers, protein additives, and stabilizers, may contain both protein and non-protein nitrogen components. In our study, we examined not only popular milk alternatives but also other milk substitutes made from specific plants. We present a reproducible and rapid method for the simultaneous qualitative and quantitative determination of the total nitrogen content in milk alternatives, focusing on applicability. Using the microchip gel electrophoretic method, we determined that the total nitrogen content differed from the protein content indicated on the packaging. Our results, along with statistical evaluations, supported the hypothesis that different brands of products, derived from the same plant source, resulted in different microfluidic profiles, likely due to the presence of additives. As expected, the microfluidic profiles of additive-free products differed from those of fortified products made from the same plant-based milk replacer. Total nitrogen content provides crucial information for individuals with kidney disease, as is essential to reduce the burden on the kidneys to slow deterioration, alleviate symptoms and avoid complications.