Iva Pukleš

Ms. Iva Pukleš

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2024 in Molecules
Verified
Journal Article
Open access
PDF file
IPIva Pukleš
Iva Pukleš
CPCsilla Páger
Csilla Páger
Nikola SakačNikola Sakač
Nikola Sakač
BSBojan Sarkanj
Bojan Sarkanj
DMDean Marković
Dean Marković
M(Marija Jozanović (Horvat)
Marija Jozanović (Horvat)
Amino acids (AAs) have broad nutritional, therapeutic, and medical significance and thus are one of the most common active ingredients of nutritional supplements. Analytical strategies for determining AAs are high-priced and often limited to methods that require modification of AA polarity or incorporation of an aromatic moiety. The aim of this work was to develop a new method for the determination of L-arginine, L-ornithine, and L-lysine on low-cost microchip electrophoresis instrumentation conjugated with capacitively coupled contactless conductivity detection. A solution consisting of 0.3 M acetic acid and 1 × 10−5 M iminodiacetic acid has been identified as the optimal background electrolyte, ensuring the shortest possible analysis time. The short migration times of amino acids (t ≤ 64 s) and method simplicity resulted in high analysis throughput with high precision and linearity (R2≥ 0.9971). The limit of detection values ranged from 0.15 to 0.19 × 10−6 M. The accuracy of the proposed method was confirmed by recovery measurements. The results were compared with CE-UV-VIS and HPLC-DAD methods and showed good agreement. This work represents the first successful demonstration of the ME-C4D analysis of L-arginine, L-ornithine, and L-lysine in real samples.

27 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Mirela SamardžićMirela Samardžić
Mirela Samardžić
MPMateja Peršić
Mateja Peršić
ASAleksandar Széchenyi
Aleksandar Széchenyi
M(Marija Jozanović (Horvat)
Marija Jozanović (Horvat)
IPIva Pukleš
Iva Pukleš
Mateja BudetićMateja Budetić
Mateja Budetić
Promethazine hydrochloride (PM) is a widely used drug so its determination is important. Solid-contact potentiometric sensors could be an appropriate solution for that purpose due to their analytical properties. The aim of this research was to develop solid-contact sensor for potentiometric determination of PM. It had a liquid membrane containing hybrid sensing material based on functionalized carbon nanomaterials and PM ions. The membrane composition for the new PM sensor was optimized by varying different membrane plasticizers and the content of the sensing material. The plasticizer was selected based on calculations of Hansen solubility parameters (HSP) and experimental data. The best analytical performances were obtained using a sensor with 2-nitrophenyl phenyl ether (NPPE) as the plasticizer and 4% of the sensing material. It had a Nernstian slope (59.4 mV/decade of activity), a wide working range (6.2 × 10−7 M–5.0 × 10−3 M), a low limit of detection (1.5 × 10−7 M), fast response time (6 s), low signal drift (−1.2 mV/h), and good selectivity. The working pH range of the sensor was between 2 and 7. The new PM sensor was successfully used for accurate PM determination in a pure aqueous PM solution and pharmaceutical products. For that purpose, the Gran method and potentiometric titration were used.

Verified
Journal Article
Open access
PDF file
IPIva Pukleš
Iva Pukleš
CPCsilla Páger
Csilla Páger
Nikola SakačNikola Sakač
Nikola Sakač
BSBojan Sarkanj
Bojan Sarkanj
Brunislav MatasovićBrunislav Matasović
Brunislav Matasović
M(Marija Jozanović (Horvat)
Marija Jozanović (Horvat)
The health supplement industry is one of the fastest growing industries in the world, but there is a lack of suitable analytical methods for the determination of active compounds in health supplements such as peptides. The present work describes an implementation of contactless conductivity detection on microchip technology as a new strategy for the electrophoretic determination of L-carnosine in complex health supplement formulations without pre-concentration and derivatization steps. The best results were obtained in the case of +1.00 kV applied for 20 s for injection and +2.75 kV applied for 260 s for the separation step. Under the selected conditions, a linear detector response of 5 × 10−6 to 5 × 10−5 M was achieved. L-carnosine retention time was 61 s. The excellent reproducibility of both migration time and detector response confirmed the high precision of the method. The applicability of the method was demonstrated by the determination of L-carnosine in three different samples of health supplements. The recoveries ranged from 91 to 105%. Subsequent analysis of the samples by CE-UV-VIS and HPLC-DAD confirmed the accuracy of the obtained results.