We aimed to investigate whether the collaboration of shear wave elastosonography (SWE) and B-mode ultrasonography (US) could be offered as diagnostic tools to assess the presence, severity, and progress of bruxism, as well as a biomarker for the effectiveness of treatment in daily clinical practice. The study was designed as a quantitative evaluation of the masseter muscles (MMs) of the clinically diagnosed bruxism patients suffering from myofascial pain and MMs of the healthy individuals. Clinical examinations were made according to the diagnostic criteria for temporomandibular disorders (DC/TMD), and pain was assessed using a visual analog scale (VAS). Painful MMs with VAS scores ≥ 4 were assigned to Group A, and healthy MMs were assigned to Group B. Also, the MMs of the painful bruxers were analyzed based on wearing occlusal splints. Group A was divided into two subgroups as splint users (Group AI) and non-users (Group AII). All the participants were scanned with dynamic US and SWE to quantify the size and stiffness of the MMs. Measurements of each muscle pair while the jaw is in a resting position (relaxation) and clenching position (contraction) were recorded. The significant differences in stiffness and thickness became visible in the relaxation state. Bruxism patients with myofascial pain had significantly harder and thinner MMs than healthy individuals. During the relaxation, the mean thickness and elasticity values were 9.17 ± 0.40 mm and 39.13 ± 4.52 kPa for Group A and 10.38 ± 0.27 and 27.73 ± 1.92 for Group B, respectively. Also, stiffer MMs were measured in Group AII (38.16 ± 3.61 kPa) than in Group AI (26.91 ± 2.13 kPa). In conclusion, the combination of SWE and US using a dynamic examination technique has the potential to be a valuable tool for the management of bruxism patients suffering from myofascial pain.
17 June 2025 in Macromolecular Materials and Engineering
The degree of conversion (DC) is a critical determinant of the biocompatibility and long‐term performance of occlusal splints. However, limited evidence exists on how emerging three‐dimensional printing technologies, particularly masked stereolithography (MSLA), affect polymerization efficiency compared to established methods. This study investigated the DC of a photopolymer‐based occlusal splint resin fabricated using stereolithography (SLA) and MSLA technologies, compared to a conventional heat‐polymerized acrylic resin. DC was assessed by Fourier Transform Infrared Spectroscopy (FTIR) at three stages for printed specimens: the unpolymerized resin, after printing and washing (DC Print), and after post‐curing (final DC). The difference between DC Print and final DC (ΔDC) represented the contribution of the post‐curing step. Conventional specimens were evaluated after mixing and after polymerization. The final DC of the conventional group was significantly higher than both SLA and MSLA groups (p < 0.001), although SLA and MSLA did not differ significantly (p > 0.05). Post‐curing significantly enhanced polymerization in both printed groups. MSLA printing achieved comparable DC to SLA while reducing production time. These findings support MSLA as a promising and time‐efficient method for splint fabrication, though further improvements in resin formulation and post‐curing protocols are warranted to match the polymerization efficiency of conventional heat‐polymerized acrylics.
Background: Eagle’s Syndrome is a unilateral or bilateral elongation of the styloid process or calcified stylohyoid ligament, along with other symptoms, such as dysphagia, facial pain, globus sensation, and headache. Stylocarotid artery syndrome is a specific type of Eagle’s syndrome that causes various clinical symptoms due to pressure on adjacent anatomical structures. Case Presentation: This study presents a case of a 57-year-old female patient with a complaint of facial pain, head and neck discomfort, globus sensation, difficulty swallowing, and dizziness during head rotation. The patient was diagnosed with a bilateral elongated styloid process through panoramic radiography and cone beam computed tomography. Due to suspicion of stylocarotid artery syndrome, further evaluation was conducted using ultrasound imaging. Conclusion: Bilateral elongated styloid processes can contribute to Stylocarotid Artery Syndrome (SAS). Ultrasound imaging, specifically B-mode and pulsed wave Doppler, proved to be valuable in detecting real-time vascular flow dynamics in extracranial vessels, highlighting its auxiliary role in the assessment of stylocarotid artery syndrome.
24 September 2026 in The Journal of Prosthetic Dentistry