We aimed to investigate whether the collaboration of shear wave elastosonography (SWE) and B-mode ultrasonography (US) could be offered as diagnostic tools to assess the presence, severity, and progress of bruxism, as well as a biomarker for the effectiveness of treatment in daily clinical practice. The study was designed as a quantitative evaluation of the masseter muscles (MMs) of the clinically diagnosed bruxism patients suffering from myofascial pain and MMs of the healthy individuals. Clinical examinations were made according to the diagnostic criteria for temporomandibular disorders (DC/TMD), and pain was assessed using a visual analog scale (VAS). Painful MMs with VAS scores ≥ 4 were assigned to Group A, and healthy MMs were assigned to Group B. Also, the MMs of the painful bruxers were analyzed based on wearing occlusal splints. Group A was divided into two subgroups as splint users (Group AI) and non-users (Group AII). All the participants were scanned with dynamic US and SWE to quantify the size and stiffness of the MMs. Measurements of each muscle pair while the jaw is in a resting position (relaxation) and clenching position (contraction) were recorded. The significant differences in stiffness and thickness became visible in the relaxation state. Bruxism patients with myofascial pain had significantly harder and thinner MMs than healthy individuals. During the relaxation, the mean thickness and elasticity values were 9.17 ± 0.40 mm and 39.13 ± 4.52 kPa for Group A and 10.38 ± 0.27 and 27.73 ± 1.92 for Group B, respectively. Also, stiffer MMs were measured in Group AII (38.16 ± 3.61 kPa) than in Group AI (26.91 ± 2.13 kPa). In conclusion, the combination of SWE and US using a dynamic examination technique has the potential to be a valuable tool for the management of bruxism patients suffering from myofascial pain.
Objectives: The purpose of this study was to evaluate the influence of different preparation designs on the marginal and internal fit of 3D-printed permanent endocrowns. Materials and methods: Typodont maxillary right first molars were prepared and divided into four groups based on different preparation designs: Group 1– butt joint with 2 mm pulp chamber depth, Group 2– butt joint with 4 mm depth, Group 3– shoulder with 2 mm depth, and Group 4– shoulder with 4 mm depth (n = 16 each). The prepared teeth were scanned and replicated as 3D-printed resin dies. Permanent endocrowns were fabricated using a ceramic-filled hybrid material and seated with light-body silicone. All restorations were rescanned, and superimposition was performed using 3D analysis software to evaluate marginal, internal, pulp chamber, and overall gaps based on multipoint measurements at standardized locations. Data were statistically analyzed using Two-Way Robust ANOVA (p < 0.05). Results: No significant differences were found between preparation types and depths for internal and overall gap values (p > 0.05). However, the highest marginal gap was measured in Group 1 (0.08 mm; p = 0.017), while the largest pulp chamber gap was recorded in Group 4 (0.15 mm; p < 0.001). Conclusions: A 1 mm shoulder preparation with a 2 mm pulp chamber depth demonstrated superior marginal and pulp chamber fit compared to other designs. While internal fit did not significantly vary among groups, this design showed the most consistent adaptation overall, supporting its clinical preference for 3D-printed permanent endocrowns. Clinical relevance: Different preparation designs may affect the fit of endocrowns. Clinicians can prefer an endocrown preparation design of 1 mm shoulder preparation with a 2 mm pulp chamber to improve the adaptation of 3D-printed permanent endocrown restorations.
3 March 2025 in Journal of Esthetic and Restorative Dentistry
Objective: This study aims to evaluate the influence of different preparation designs on the marginal and internal fit of 3D‐printed permanent endocrowns using circumferential 3D analysis.Materials and Methods: Maxillary right first molar typodont teeth were prepared with four designs (n = 12); Group 1‐butt joint & 2 mm pulp chamber, Group 2‐butt joint & 4 mm pulp chamber, Group 3‐shoulder & 2 mm pulp chamber, and Group 4‐shoulder & 4 mm pulp chamber. Teeth were scanned, replicated as 3D‐printed master dies, and restored with 3D‐printed ceramic‐filled hybrid endocrowns. After seating with Fit Checker, superimposed scans were analyzed circumferentially at standard points. Marginal, internal, pulp chamber, and overall gap values were measured from mesiodistal, buccolingual, and oblique sections. Statistical analysis was performed using two‐way anova and post hoc Tukey tests (α = 0.05).Results: Margin design and pulp chamber depth interactions revealed significant differences (p < 0.05). The least marginal fit was in Group 2, while the best internal and overall fit was in Group 3 (p < 0.05).Conclusion: Different preparation designs have an impact on the fit of endocrowns. A shoulder margin design and a 2‐mm pulp chamber depth exhibited a better internal fit of 3D‐printed ceramic‐filled hybrid endocrowns through circumferential 3D analysis.Clinical Significance: Circumferential 3D analysis reveals that variable preparation designs significantly influence the fit of endocrowns, guiding clinicians in selecting optimal designs for improved clinical outcomes.
17 June 2025 in Macromolecular Materials and Engineering
The degree of conversion (DC) is a critical determinant of the biocompatibility and long‐term performance of occlusal splints. However, limited evidence exists on how emerging three‐dimensional printing technologies, particularly masked stereolithography (MSLA), affect polymerization efficiency compared to established methods. This study investigated the DC of a photopolymer‐based occlusal splint resin fabricated using stereolithography (SLA) and MSLA technologies, compared to a conventional heat‐polymerized acrylic resin. DC was assessed by Fourier Transform Infrared Spectroscopy (FTIR) at three stages for printed specimens: the unpolymerized resin, after printing and washing (DC Print), and after post‐curing (final DC). The difference between DC Print and final DC (ΔDC) represented the contribution of the post‐curing step. Conventional specimens were evaluated after mixing and after polymerization. The final DC of the conventional group was significantly higher than both SLA and MSLA groups (p < 0.001), although SLA and MSLA did not differ significantly (p > 0.05). Post‐curing significantly enhanced polymerization in both printed groups. MSLA printing achieved comparable DC to SLA while reducing production time. These findings support MSLA as a promising and time‐efficient method for splint fabrication, though further improvements in resin formulation and post‐curing protocols are warranted to match the polymerization efficiency of conventional heat‐polymerized acrylics.
10 April 2025 in The Journal of Prosthetic Dentistry