Shangting Wang

Ms. Shangting Wang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
YHYinghua Hu
Yinghua Hu
YMYang Ming
Yang Ming
YZyuanfei zhu
yuanfei zhu
SWShangting Wang
Shangting Wang
Frequency tracking and amplitude control are essential for piezoelectric transducers. Frequency tracking ensures the piezoelectric transducer operates at the resonant frequency for maximum power output, and amplitude control regulates the mechanical motion of the output. This paper presents a novel driver based on a push–pull inverter for piezoelectric transducers. The proposed driver realizes the frequency tracking and amplitude control scheme by a voltage sensing bridge in the case of transformer secondary matching, guaranteeing automatic frequency tracking and precise mechanical functions regardless of environmental and load variations. The proposed scheme is verified by the ultrasonic scalpel and the ultrasonic motor (USM). The experimental results show that this scheme reduces the build-up time from 10 ms to 3 ms and loaded frequency variations from 250 Hz to 200 Hz. In addition, the amplitude control performance was further observed on USM for various loads. The overshoot is less than 5.4% under different load torques. Therefore, the proposed scheme improves the load adaptability and stability of piezoelectric transducers and promotes the application of piezoelectric transducers under various conditions.

22 July 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
YLYuan Liu
Yuan Liu
YZyuanfei zhu
yuanfei zhu
SWShangting Wang
Shangting Wang
HFHualin Fu
Hualin Fu
ZLZhexin Lu
Zhexin Lu
YMYang Ming
Yang Ming
Background: In recent years, intravascular micro-axial blood pumps have been increasingly used in the treatment of patients with cardiogenic shock. The flow rate of such blood pumps requires adjustment based on the patient’s physiological condition. Compared to a stable flow state with fixed rotation speed, adjusting the speed of blood pump impeller to alter flow rate may lead to additional hemolysis. This study aimed at elucidating the relationship between adjusting interval of a blood pump’s impeller speed and the hemolysis index. Methods: By comparing simulation results with P-Q characteristic curves of the blood pump measured by experiments, the accuracy of the blood pump flow field simulation model was confirmed. In this study, a drainage tube was employed as the device analogous to an intravascular micro-axial blood pump for achieving similar shear stress levels and residence times. The hemolysis finite element prediction method based on a power-law model was validated through hemolysis testing of porcine blood flow through the drainage tube. The validated models were subsequently utilized to investigate the impact of impeller speed adjusting intervals on hemolysis in the blood pump. Results: Compared to steady flow, the results demonstrate that the hemolysis index increased to 6.3% when changing the blood pump flow rate from 2 L/min to 2.5 L/min by adjusting the impeller speed within 0.072 s. Conclusions: An adjustment time of impeller speed longer than 0.072 s can avoid extra hemolysis when adjusting the intravascular micro-axial blood pump flow rate from 2 L/min to 2.5 L/min.

27 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SWShangting Wang
Shangting Wang
YMYang Ming
Yang Ming
YLYuan Liu
Yuan Liu
JYJunwen Yu
Junwen Yu
In ex vivo heart perfusion (EVHP), the control of aortic pressure (AoP) is critical for maintaining the heart’s physiologic aerobic metabolism. However, the complexity of and variability in cardiac parameters present a challenge in achieving the rapid and accurate regulation of AoP. In this paper, we propose a method of AoP control based on deep reinforcement learning for EVHP in Langendorff mode, which can adapt to the variations in cardiac parameters. Firstly, a mathematical model is developed by coupling the coronary artery and the pulsatile blood pump models. Subsequently, an aortic pressure control method based on the Deep Deterministic Policy Gradient (DDPG) algorithm is proposed. This method enables the regulation of the blood pump and the realization of closed-loop control. The control performance of the proposed DDPG method, the traditional proportional–integral–derivative (PID) method, and the fuzzy PID method are compared by simulating single and mixed changes in mean aortic pressure target values and coronary resistance. The proposed method exhibits superior performance compared to the PID and fuzzy PID methods under mixed factors, with 68.6% and 66.4% lower settling times and 70.3% and 54.1% lower overshoot values, respectively. This study demonstrates that the proposed DDPG-based method can respond more rapidly and accurately to different cardiac conditions than the conventional PID controllers.