This brief proposes a fully digital background estimation technique for timing mismatch in time-interleaved analog-to-digital converters (TIADCs). The improved estimation technique is a feedback method based on statistics and Taylor series expansion. Besides, an exponential moving average (EMA) with adaptive coefficient is introduced to prevent performance degradation near specific frequencies, which improves the robustness of calibration. This estimation method can maintain high performance of accuracy and convergence speed across nearly the entire input frequency band. Furthermore, it is not restricted to the number of channels, amplitude, and frequency of the input signal. The effectiveness of this technique is demonstrated through off-chip calibration of a commercial 12-bit four-channel 3 GS/s TIADC using a 1.01 GHz input signal. Results indicate that the proposed method converges after approximately 3000 samples, reducing spurious signals stemming from timing mismatch by 20.6, 19.3, and 18.5 dB, respectively.
Timing-mismatch errors among channels in time-interleaved analog-to-digital converters (TIADCs) greatly degrade the whole performance of the system. Therefore, techniques for calibrating timing mismatch are indispensable, and a new fully-digital calibration technique is presented in this article. Based on a Hilbert filter, modified moving averagers (MMAs) and inverse cosine functions, the proposed estimation algorithm is fast (within 1200 sample points) and accurate. Meanwhile, the coordinate rotational digital computer (CORDIC) algorithm, which is used to implement inverse cosine functions, is also improved, giving it higher precision. In addition, a compensation method based on second-order Taylor series approximation with less hardware resource consumption is provided. Through analyses and simulations, this calibration technique proved to be suitable for TIADCs with an arbitrary number of channels, in which the signal-to-noise and distortion ratio (SNDR) and the spurious-free dynamic range (SFDR) were, respectively, improved from 24.06 dB and 24.57 dB to 67.96 dB and 85.69 dB.
7 September 2023 in AEU - International Journal of Electronics and Communications
This paper proposes a fully digital background calibration method for time-interleaved analog-to-digital converter (TIADC) mismatches. The method analyzes the frequency and phase of spurious signals caused by three types of mismatches in TIADCs in the frequency domain. By utilizing the Hilbert transform and frequency shifting, orthogonal basis signals located at the mismatch frequencies can be constructed. The calibration of mismatches is achieved by linearly combining the orthogonal basis signals with the estimated coefficients and subtracting them from the original signal. The estimation of coefficients is determined by evaluating the correlation between the linear combination of orthogonal basis signals and the calibrated signal. Furthermore, an exponential moving average (EMA) and least mean square (LMS) algorithm are introduced to expedite the coefficient estimation process. The entire calibration process converges in merely 600 samples, significantly improving the convergence speed. By monitoring the amplitude of the input signal and adjusting the LMS step, the algorithm is functional under different amplitude signals, enhancing the robustness. An off-chip calibration is conducted based on a commercial 14-bit, 8-channel, 2.4GSPS TIADC. Results indicate that all spurious signals are suppressed below 80 dB, and the convergence rate is consistent with the simulation.
This paper proposes an all-digital calibration algorithm that utilizes a reference channel to suppress the timing mismatch in the Time-Interleaved Analog-to-Digital Converter (TIADC). The output of the reference channel is aligned with each sub-channel in turn, therefore enabling the simultaneous sampling and conversion of the same input signal. First, the statistical characteristics across the channels are employed for estimating the timing mismatch; then, by comparing the output difference between the reference channel and the sub-channels that are sampled simultaneously, the deviation of the derivator can be calibrated. Finally, combining both calibration results yields an accurate final output. This proposed algorithm provides an effective solution to improve TIADC performance in high-speed data acquisition systems. The proposed architecture is applied to a 12-bit 2.4 GS/s four-channel TIADC model, and then its effectiveness is verified. The simulation results exhibit that the Effective Number Of Bits (ENOB) at an input signal frequency of 984 MHz shows a remarkable improvement from 6.88 bits to 11.92 bits. The effectiveness of this technique is also demonstrated through the off-chip calibration of a commercial 12-bit four-channel 2 GS/s TIADC using a 680 MHz input signal that is based on the actual chip results.