Sherry Chen Xuexia Li

Dr. Sherry Chen Xuexia Li

Science Systems and Applications (United States), Lanham, Maryland, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
JSjunqiang sun
junqiang sun
Jack XiongJack Xiong
Jack Xiong
NLNing Lei
Ning Lei
SLSherry Chen Xuexia Li
Sherry Chen Xuexia Li
KTKevin Twedt
Kevin Twedt
AAAmit Angal
Amit Angal
The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership (SNPP) has successfully operated on-orbit for nearly ten years since its launch in October 2011, continuously making global observations and improving studies of changes in the Earth’s climate and environment. VIIRS has 22 spectral bands, among which 14 are reflective solar bands (RSBs) covering a spectral range from 0.41 to 2.25 μm. The SNPP VIIRS RSBs are primarily calibrated by the onboard solar diffuser (SD), with its on-orbit degradation tracked by an onboard SD stability monitor (SDSM). The near-monthly scheduled lunar observations, together with the sensor responses over stable ground targets, have contributed to the sensor’s mission-long on-orbit calibration and characterization. Numerous improvements have been made in the RSB calibration methodology since SNPP VIIRS was launched, and the RSB calibration has reached a mature stage after almost ten years of on-orbit operation. SNPP is a joint NASA/NOAA mission and there are two teams, the NASA VIIRS Calibration Support Team (VCST) and the NOAA VIIRS Sensor Data Record Team, which are dedicated to SNPP VIIRS on-orbit calibration. In this paper, we focus on the calibration performed by the NASA VCST. The SNPP VIIRS RSB calibration methodologies used to produce the calibration coefficient look up tables for the latest NASA Level 1B Collection 2 products are reviewed and the calibration improvements incorporated in this collection are described. Recent calibration changes include the removal of image striping caused by non-uniform degradation of the SD, improvements to the method for combining lunar and SD data, mitigation of the effects due a recent anomaly in the SD measurements, estimation of the SD degradation beyond 935 nm, and fitting strategy improvements for look-up table delivery. Overall, the SNPP VIIRS RSBs have performed well since its launch and continue to meet design specifications.

22 January 2021 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
NLNing Lei
Ning Lei
Jack XiongJack Xiong
Jack Xiong
QMQiaozhen Mu
Qiaozhen Mu
SLSherry Chen Xuexia Li
Sherry Chen Xuexia Li
TCTiejun Chang
Tiejun Chang
The Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership (SNPP) satellite regularly performs on-orbit radiometric calibration of its reflective solar bands (RSBs), primarily through observations of an onboard sunlit solar diffuser (SD). The on-orbit change of the SD bidirectional reflectance distribution function (BRDF) value, quantified by a numerical factor called the H-factor, is determined by the onboard SD stability monitor. Our previous study showed that the H-factor is solar angle- and view direction-dependent. In this study, we determine the dependence of the H-factor on the detector SD view footprint location. We fit an empirical model to the NASA Collection 1 SNPP VIIRS Level 1B (L1B) spectral reflectance difference across the detectors in an RSB over uniform Earth scenes of the Libya 4 desert and deep convective clouds (DCCs). We apply the model predicted SD-positional-dependent H-factor to calibrate the RSBs. Under this new calibration scheme, the original unreal striping is removed from the homogeneous Libya 4 desert and the DCC images, as well as the original unreal striping from the Dunhuang desert image. The SD-positional-dependent H-factor has been used to calculate the SNPP VIIRS RSB radiometric correction factor for the NASA Collection 2.0 SNPP VIIRS L1B products.

9 September 2021 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
KTKevin Twedt
Kevin Twedt
NLNing Lei
Ning Lei
Jack XiongJack Xiong
Jack Xiong
AAAmit Angal
Amit Angal
SLSherry Chen Xuexia Li
Sherry Chen Xuexia Li
JSjunqiang sun
junqiang sun
The NOAA-20 (N20) satellite was launched on November 18, 2017 carrying the second Visible Infrared Imaging Radiometer Suite (VIIRS) instrument. Immediately following the launch, the VIIRS passed a series of intensive calibration and validation tests, after which regular calibration and operation activities have continued successfully for more than three years. The production of NASA Collection 2 Level 1B (C2 L1B) for N20 VIIRS began in summer 2019. In this article, we evaluate the early mission performance of the N20 VIIRS reflective solar bands (RSB) covering the first three full years of operation. The calibrated RSB gains are calculated primarily from the onboard solar diffuser (SD) and used in generating the C2 L1B reflectance and radiance products. We also show the on-orbit performance of the instrument noise, signal-to-noise ratio (SNR), and a reflectance uncertainty assessment. Comparisons are made to the first three years of operation of the first VIIRS instrument, aboard the Suomi National Polar-orbiting Partnership (SNPP) satellite. We evaluate the long-term stability of the calibrated N20 RSB reflectance product by looking at the long-term trends of lunar observations and data from the pseudo-invariant Libya 4 desert site. The N20 RSB have had excellent early mission performance, with changes in the gain of less than 0.5% in the first three years across all detectors, stable L1B reflectance, and very stable values of detector SNR and reflectance uncertainty.

27 September 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
AWAisheng Wu
Aisheng Wu
Jack XiongJack Xiong
Jack Xiong
AAAmit Angal
Amit Angal
QMQiaozhen Mu
Qiaozhen Mu
SLSherry Chen Xuexia Li
Sherry Chen Xuexia Li
Two MODIS sensors onboard the Terra and Aqua spacecraft have been successfully operating for over twenty-three and twenty-one years, respectively, providing the worldwide user community with high-quality imagery and radiometric Earth observations of the land, atmosphere, cryosphere, and oceans. This study provides an assessment of the radiometric calibration stability and consistency of Terra and Aqua MODIS RSB using the L1B from the upcoming Collection 7 release. Several independent vicarious approaches based on measurements from the Libya-4 desert, Dome C, DCC, and SNO are used to assess the calibration stability at the beginning of scan, nadir, and end of scan. Results indicate that both Terra and Aqua RSB are stable to within 1% over their mission periods. Comparison of the normalized reflectances with either a BRDF model or a common reference sensor provides a radiometric assessment of Terra and Aqua calibration consistency. Comparison results show the VIS/NIR bands are in good agreement around the nadir and at the beginning of the scan for all the approaches. For cases at the end of the scan, the agreement varies depending on the approach but is typically within ±2%. The differences observed in the SWIR bands are slightly larger than the VIS/NIR bands, which are likely due to their high sensitivity to atmospheric conditions and relatively larger electronic crosstalk impact on the Terra instrument.

30 November 2016 in Remote Sensing
Verified
Journal Article
Open access
PDF file
SLSherry Chen Xuexia Li
Sherry Chen Xuexia Li
AWAisheng Wu
Aisheng Wu
Jack XiongJack Xiong
Jack Xiong
NLNing Lei
Ning Lei
ZWZhipeng Wang
Zhipeng Wang
KCKwofu Chiang
Kwofu Chiang
In this study, the observations from S-NPP VIIRS Day-Night band (DNB) and Moderate resolution bands (M bands) of Libya 4 and Dome C over the first four years of the mission are used to assess the DNB low gain calibration stability. The Sensor Data Records produced by NASA Land Product Evaluation and Algorithm Testing Element (PEATE) are acquired from nearly nadir overpasses for Libya 4 desert and Dome C snow surfaces. A kernel-driven bidirectional reflectance distribution function (BRDF) correction model is used for both Libya 4 and Dome C sites to correct the surface BRDF influence. At both sites, the simulated top-of-atmosphere (TOA) DNB reflectances based on SCIAMACHY spectral data are compared with Land PEATE TOA reflectances based on modulated Relative Spectral Response (RSR). In the Libya 4 site, the results indicate a decrease of 1.03% in Land PEATE TOA reflectance and a decrease of 1.01% in SCIAMACHY derived TOA reflectance over the period from April 2012 to January 2016. In the Dome C site, the decreases are 0.29% and 0.14%, respectively. The consistency between SCIAMACHY and Land PEATE data trends is good. The small difference between SCIAMACHY and Land PEATE derived TOA reflectances could be caused by changes in the surface targets, atmosphere status, and on-orbit calibration. The reflectances and radiances of Land PEATE DNB are also compared with matching M bands and the integral M bands based on M4, M5, and M7. The fitting trends of the DNB to integral M bands ratios indicate a 0.75% decrease at the Libya 4 site and a 1.89% decrease at the Dome C site. Part of the difference is due to an insufficient number of sampled bands available within the DNB wavelength range. The above results indicate that the Land PEATE VIIRS DNB product is accurate and stable. The methods used in this study can be used on other satellite instruments to provide quantitative assessments for calibration stability.

29 September 2017
Verified
Conference Paper
Closed access
SLSherry Chen Xuexia Li
Sherry Chen Xuexia Li
AWAisheng Wu
Aisheng Wu
NCNa Chen
Na Chen
XXXiaoxiong J. Xiong
Xiaoxiong J. Xiong