Xin Sun

Dr. Xin Sun

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2024 in Science Advances
Verified
Journal Article
Open access
QLQibo Lin
Qibo Lin
ZLZhaoxi Li
Zhaoxi Li
BWBo Wang
Bo Wang
MZMengqing Zhou
Mengqing Zhou
YXYang Xie
Yang Xie
Zeyu ChenZeyu Chen
Zeyu Chen
Optical imaging and phototherapy in deep tissues face notable challenges due to light scattering. We use encoded acoustic holograms to generate three-dimensional acoustic fields within the target medium, enabling instantaneous and robust modulation of the volumetric refractive index, thereby noninvasively controlling the trajectory of light. Through this approach, we achieved a remarkable 24.3% increase in tissue heating rate in vitro photothermal effect tests on porcine skin. In vivo photoacoustic imaging of mouse brain vasculature exhibits an improved signal-to-noise ratio through the intact scalp and skull. These findings demonstrate that our strategy can effectively suppress light scattering in complex biological tissues by inducing low-angle scattering, achieving an effective depth reaching the millimeter scale. The versatility of this strategy extends its potential applications to neuroscience, lithography, and additive manufacturing.

6 November 2024 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
YZYushun Zeng
Yushun Zeng
XSXin Sun
Xin Sun
JZJunhang Zhang
Junhang Zhang
CCChi-Feng Chang
Chi-Feng Chang
BLBaoqiang Liu
Baoqiang Liu
Qifa ZhouQifa Zhou
Qifa Zhou
Wearable ultrasound has been widely developed for long-term, continuous imaging without the need for bulky system manipulation and repeated manual locating. To potentially lead to more accurate and reliable imaging monitoring, this work presents the design, fabrication, and evaluation of a novel high-frequency wearable ultrasound array belt (WUAB) for small animal echocardiography. The fabrication process involved precise dicing technology for a λ-pitch design. The 20 MHz WUAB consists of two matching layers, piezoelectric composite with 128 channels, customized flexible circuit substrate, acoustic backing layer, and customized belt structure with designed end tip and insertion point for wearability. The resulting WUAB demonstrates sensitivity of -5.69 ± 2.5 dB and fractional bandwidth of 57 ± 5 %. In vivo experiments on rat model showed expected echocardiography and B-mode images of rat heart. These results represent significant promise for future longitudinal studies in small animals and real-time physiological monitoring.

2 December 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
HXHaoyue Xue
Haoyue Xue
XHXing Huang
Xing Huang
XSXin Sun
Xin Sun
KWKai Wu
Kai Wu
ZTZhi Tan
Zhi Tan
Jiagang WuJiagang Wu
Jiagang Wu
Medical ultrasound technology provides zero-radiation, non-invasive, high-penetration and high-resolution evaluation of body organs for diagnosing various diseases. However, challenges remain for emerging ultrasonic bioelectronics in terms of novel material exploration, structural flexibility, wearable integration. Here, we present a 64-channel lead-free ultrasound line imaging array transducer developed from biofriendly potassium sodium niobate-based ceramics, which enables wearable multimodal imaging through the incorporation of multilevel material structure engineering and flexible device design. On the materials engineering aspect, the lead-free ceramics exhibits superior piezoelectricity (d33 ~ 630 pC N−1, k33 ~ 0.66) by restoring long range ferroelectric ordering and suppressing excessive polar nanoregions. In terms of device architecture, the miniaturized array integrates 64 lead-free 1-3 piezo-elements on a flexible printed circuit board and a bioadhesive hydrogel layer for acoustic coupling and robust adhesion to the skin, enabling portable, high-precision operation with a center frequency of 8.36 MHz and a −6 dB bandwidth of over 40%. In wearable applications for the human body, this array demonstrates real-time high-resolution vascular imaging, blood flow dynamics, and elastography of muscle dynamics, advancing the next generation of wearable ultrasound technologies.

16 May 2025 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
RWRobert Wodnicki
Robert Wodnicki
JFJosquin Foiret
Josquin Foiret
BLBaoqiang Liu
Baoqiang Liu
NLNing Lu
Ning Lu
XSXin Sun
Xin Sun
KFKatherine W. Ferrara
Katherine W. Ferrara
Large aperture 2D arrays benefit from improved lateral resolution at depth, due to the dependence of beamwidth on the inverse of the aperture width, and improved contrast resolution due to electronic focusing. We have been developing modular large aperture multi-row 1,024 (64 azimuth × 16 elevation) element, 2D arrays based on custom-designed and locally integrated Application Specific Integrated Circuit (ASIC) multiplexing devices. The implemented handheld large array prototype probe for human imaging consists of multiple rows with multiplexed synthetic aperture in elevation and planewave transmits in azimuth. The pitch of the acoustic array is 650 μm in azimuth by 1,000 μm in elevation, with a 2.4 MHz (FBW=88%) center frequency and total active aperture of 42 mm × 16 mm. We interfaced the large aperture array and multiplexing ASICs, along with local preamplifier devices for improved sensitivity, and a local FPGA for digital ASIC control, to a configurable ultrasound imaging platform and demonstrate 2D orthogonal and full 3D-beamformed imaging. The implemented imaging prototype includes local buffering for improved sensitivity of the high impedance 2D array elements, and realizes penetration down to 140 mm, experimental lateral/axial resolution at 67 mm of 1.1 mm/0.4 mm, and maximum experimental CNR of 2.1 for 8 mm cylindrical cysts, and 1.7 for 10 mm spherical cysts. We demonstrate in-vivo imaging of liver in human volunteers utilizing a hermetically-sealed and safety-validated handheld prototype of the large 2D array. Preliminary results are promising for clinical imaging in future studies.

30 December 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
CWChenjun Wu
Chenjun Wu
QSQi Sun
Qi Sun
XLXiangdong Liu
Xiangdong Liu
XSXin Sun
Xin Sun
Zeyu ChenZeyu Chen
Zeyu Chen
HSHan Shan
Han Shan
Liposomes possess the potential to enhance drug solubility, prolong the duration of circulation, and augment drug accumulation at the tumor site through passive and active targeting strategies. However, there is a lack of studies examining the in vivo tumor penetration capabilities of liposomes of varying sizes, which hampers the development of drug delivery systems utilizing liposomal nanocarriers. Here, we present an indocyanine green (ICG)-loaded liposomes-assisted photoacoustic computed tomography (PACT) for directly evaluating the tumor penetration ability of liposomal nanocarriers in vivo. Through the utilization of microfluidic mixing combined with extrusion techniques, we successfully prepare liposomes encapsulating ICG in both large (192.6 ± 8.0 nm) and small (61.9 ± 0.6 nm) sizes. Subsequently, we designed a dual-wavelength PACT system to directly monitor the in vivo tumor penetration of large- and small-size ICG-encapsulated liposomes. In vivo PACT experiments indicate that ICG-loaded liposomes of smaller size exhibit enhanced penetration capability within tumor tissues. Our work presents a valuable approach to directly assess the penetration ability of liposomal nanocarriers in vivo, thereby facilitating the advancement of drug delivery systems with enhanced tumor penetration and therapeutic efficacy.

29 February 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
ARalfa rossi
alfa rossi
YZYushun Zeng
Yushun Zeng
MRMojtaba Rahimi
Mojtaba Rahimi
TSTae Yun Son
Tae Yun Son
MHMichael Heiferman
Michael Heiferman
Xincheng YaoXincheng Yao
Xincheng Yao
Ultrasound A-scan is an important tool for quantitative assessment of ocular lesions. However, its usability is limited by the difficulty of accurately localizing the ultrasound probe to a lesion of interest. In this study, a transparent LiNbO3 single crystal ultrasound transducer was fabricated, and integrated with a widefield fundus camera to guide the ultrasound local position. The electrical impedance, phase spectrum, pulse-echo performance, and optical transmission spectrum of the ultrasound transducer were validated. The novel fundus camera-guided ultrasound probe was tested for in vivo measurement of rat eyes. Anterior and posterior segments of the rat eye could be unambiguously differentiated with the fundus photography-guided ultrasound measurement. A model eye was also used to verify the imaging performance of the prototype device in the human eye. The prototype shows the potential of being used in the clinic to accurately measure the thickness and echogenicity of ocular lesions in vivo.