alfa rossi

Mr. alfa rossi

Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
ARalfa rossi
alfa rossi
MRMojtaba Rahimi
Mojtaba Rahimi
DLDavid Le
David Le
TSTaeyoon Son
Taeyoon Son
MHMichael J. Heiferman
Michael J. Heiferman
Xincheng YaoXincheng Yao
Xincheng Yao
Fundus photography is indispensable for the clinical detection and management of eye diseases. Low image contrast and small field of view (FOV) are common limitations of conventional fundus photography, making it difficult to detect subtle abnormalities at the early stages of eye diseases. Further improvements in image contrast and FOV coverage are important for early disease detection and reliable treatment assessment. We report here a portable, wide FOV fundus camera with high dynamic range (HDR) imaging capability. Miniaturized indirect ophthalmoscopy illumination was employed to achieve the portable design for nonmydriatic, widefield fundus photography. Orthogonal polarization control was used to eliminate illumination reflectance artifacts. With independent power controls, three fundus images were sequentially acquired and fused to achieve HDR function for local image contrast enhancement. A 101° eye-angle (67° visual-angle) snapshot FOV was achieved for nonmydriatic fundus photography. The effective FOV was readily expanded up to 190° eye-angle (134° visual-angle) with the aid of a fixation target without the need for pharmacologic pupillary dilation. The effectiveness of HDR imaging was validated with both normal healthy and pathologic eyes, compared to a conventional fundus camera.

9 February 2024 in Communications Engineering
Verified
Journal Article
Open access
PDF file
DLDavid Le
David Le
TSTaeyoon Son
Taeyoon Son
TKTae-Hoon Kim
Tae-Hoon Kim
TATobiloba Adejumo
Tobiloba Adejumo
MAMansour Abtahi
Mansour Abtahi
Xincheng YaoXincheng Yao
Xincheng Yao
Optical coherence tomography angiography (OCTA) provides unrivaled capability for depth-resolved visualization of retinal vasculature at the microcapillary level resolution. For OCTA image construction, repeated OCT scans from one location are required to identify blood vessels with active blood flow. The requirement for multi-scan-volumetric OCT can reduce OCTA imaging speed, which will induce eye movements and limit the image field-of-view. In principle, the blood flow should also affect the reflectance brightness profile along the vessel direction in a single-scan-volumetric OCT. Here we report a spatial vascular connectivity network (SVC-Net) for deep learning OCTA construction from single-scan-volumetric OCT. We quantitatively determine the optimal number of neighboring B-scans as image input, we compare the effects of neighboring B-scans to single B-scan input models, and we explore different loss functions for optimization of SVC-Net. This approach can improve the clinical implementation of OCTA by improving transverse image resolution or increasing the field-of-view.

6 October 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
MRMojtaba Rahimi
Mojtaba Rahimi
ARalfa rossi
alfa rossi
TSTaeyoon Son
Taeyoon Son
DTDevrim Toslak
Devrim Toslak
DLDavid Le
David Le
Xincheng YaoXincheng Yao
Xincheng Yao
Multi-spectral widefield fundus photography is valuable for the clinical diagnosis and management of ocular conditions that may impact both central and peripheral regions of the retina and choroid. Trans-palpebral illumination has been demonstrated as an alternative to transpupillary illumination for widefield fundus photography without requiring pupil dilation. However, spectral efficiency can be complicated due to the spatial variance of the light property through the palpebra and sclera. This study aims to investigate the effect of light delivery location on spectral efficiency in trans-palpebral illumination. Four narrow-band light sources, covering both visible and near infrared (NIR) wavelengths, were used to evaluate spatial dependency of spectral illumination efficiency. Comparative analysis indicated a significant dependence of visible light efficiency on spatial location, while NIR light efficiency is only slightly affected by the illumination location. This study confirmed the pars plana as the optimal location for delivering visible light to achieve color imaging of the retina. Conversely, spatial location is not critical for NIR light imaging of the choroid.

24 October 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
ARalfa rossi
alfa rossi
MRMojtaba Rahimi
Mojtaba Rahimi
TSTaeyoon Son
Taeyoon Son
RCR. V. Paul Chan
R. V. Paul Chan
MHMichael J. Heiferman
Michael J. Heiferman
Xincheng YaoXincheng Yao
Xincheng Yao
The purpose of this study is to demonstrate the feasibility of using polarization maintaining photons for enhanced contrast imaging of the retina. Orthogonal-polarization control has been frequently used in conventional fundus imaging systems to minimize reflection artifacts. However, the orthogonal-polarization configuration also rejects the directly reflected photons, which preserve the polarization condition of incident light, from the superficial layer of the fundus, i.e., the retina, and thus reduce the contrast of retinal imaging. We report here a portable fundus camera which can simultaneously perform orthogonal-polarization control to reject back-reflected light from the ophthalmic lens and parallel-polarization control to preserve the backscattered light from the retina which partially maintains the polarization state of the incoming light. This portable device utilizes miniaturized indirect ophthalmoscopy illumination to achieve non-mydriatic imaging, with a snapshot field of view of 101° eye-angle (67° visual-angle). Comparative analysis of retinal images acquired with a traditional orthogonal-polarization fundus camera from both normal and diseased eyes was conducted to validate the usefulness of the proposed design. The parallel-polarization control for enhanced contrast in high dynamic range imaging has also been validated.

18 June 2024 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
BEBehrouz Ebrahimi
Behrouz Ebrahimi
DLDavid Le
David Le
MAMansour Abtahi
Mansour Abtahi
ADAlbert K. Dadzie
Albert K. Dadzie
ARalfa rossi
alfa rossi
Xincheng YaoXincheng Yao
Xincheng Yao
Retinopathy of prematurity (ROP) occurs in premature infants due to underdeveloped retinal vasculature at birth,1 causing abnormal blood vessel growth at the boundary of partially vascularized and avascular retinal areas.2,3 ROP is the leading preventable cause of childhood blindness worldwide.4,5 The severity of ROP is classified into five stages, corresponding to mild to severe stages.6 Appropriate detection and accurate ROP diagnosis in premature infants is crucial to prevent irreversible vision loss and associated visual developmental complications such as astigmatism, myopia, glaucoma, cataracts, anisometropia, amblyopia, strabismus, and retinal detachment.7,8

2 October 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
ARalfa rossi
alfa rossi
DTDevrim Toslak
Devrim Toslak
MEMuhammet Kazim Erol
Muhammet Kazim Erol
MRMojtaba Rahimi
Mojtaba Rahimi
TSTaeyoon Son
Taeyoon Son
Xincheng YaoXincheng Yao
Xincheng Yao
Widefield fundus photography is critical for the detection, documentation, and management of pediatric eye diseases. Existing clinical pediatric fundus cameras offer a limited field of view (FOV) and suboptimal image contrast, hindering comprehensive peripheral retina examination. Additionally, the high cost and lack of portability of commercial devices restrict their use in resource-limited settings. We introduce a cost-effective smartphone-based pediatric camera (PedCam) that provides a 180° eye angle (126° visual angle) snapshot FOV. Utilizing trans-pars planar illumination, the device enables nonmydriatic imaging by allocating the pupil exclusively for imaging, eliminating the need for pharmacological pupillary dilation. By adjusting the optical axis of the PedCam relative to the ocular axis, the effective FOV can be expanded up to 240° eye angle (180° visual angle), enabling complete retinal evaluation. This innovative smartphone PedCam represents a significant advancement in affordable telemedicine for the screening, monitoring, and management of retinopathy of prematurity and other pediatric eye conditions.