Premesh Shehan  Lowe

Dr. Premesh Shehan Lowe

Nuclear Advanced Manufacturing Research Centre (Nuclear AMRC), S60 5WG Rotherham, UK
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
HLHabiba Lais
Habiba Lais
PLPremesh Shehan Lowe
Premesh Shehan Lowe
Tat-Hean GanTat-Hean Gan
Tat-Hean Gan
LWLuiz C. Wrobel
Luiz C. Wrobel
Fouling build up is a well-known problem in the offshore industry. Accumulation of fouling occurs in different structures, e.g. offshore pipes, ship hulls, floating production platforms. The type of fouling that accumulates is dependent on environmental conditions surrounding the structure itself. Current methods deployed for fouling removal span across hydraulic, chemical and manual, all sharing the common disadvantage of necessitating halting production for the cleaning process to commence. Conventionally, ultrasound is used in ultrasonic baths to clean a submerged component by the generation and implosion of cavitation bubbles on the fouled surface; this method is particularly used in Reverse Osmosis applications. However, this requires the submersion of the fouled structure and thus may require a halt to production. Large fouled structures such as pipelines may not be accommodated. The application of high power ultrasonics is proposed in this work as a means to remove fouling on a structure whilst in operation. The work presented in this paper consists of the development of a finite element analysis model based on successful cleaning results from a pipe fouled with calcite on the inner pipe wall. A Polytec 3D Laser Doppler Vibrometer was used in this investigation to study the fouling removal process. Results show the potential of high power ultrasonics for fouling removal in pipe structures from the wave propagation across the structure under excitation, and are used to validate a COMSOL model to determine cleaning patterns based on pressure and displacement distributions for future transducer array design and optimization.

14 October 2015 in IEEE Sensors Journal
Verified
Journal Article
Open access
PLPremesh Shehan Lowe
Premesh Shehan Lowe
RSRuth M. Sanderson
Ruth M. Sanderson
NBNikolaos V. Boulgouris
Nikolaos V. Boulgouris
AHAlex G. Haig
Alex G. Haig
WBWamadeva Balachandran
Wamadeva Balachandran
Less attention has been given to the inspection using the first longitudinal guided wave mode due to its attenuative and dispersive properties at commonly used ultrasonic guided waves (UGWs) operating frequency region (20-100 kHz). However, the first longitudinal guided wave mode has higher flaw sensitivity due to having a shorter wave length and having higher number of non-axisymmetric wave modes at a given frequency. This enhances the capabilities of advanced UGW techniques which require higher number of non-axisymmetric modes. This study has been performed to investigate the potential of mode purity and flaw sensitivity of the first longitudinal guided wave mode compared with other axisymmetric modes in the UGW operating frequency region. Numerical and experimental investigation have been conducted to investigate pure excitation and flaw sensitivity of the first longitudinal guided wave mode. It has been validated that the first longitudinal guided wave mode can be used in the UGW inspection effectively in isolation by adopting transducers with out-of-plane vibration. This reduces the cost and the weight of the UGW inspection tooling. The flaw sensitivity of the first longitudinal guided wave mode has been investigated by aid of an empirically validated UGW focusing technique. Under the studied conditions in this paper, the first longitudinal guided wave mode has $\sim5$ times higher flaw sensitivity compared with the second longitudinal guided wave mode and $\sim 2.5$ times higher than the first torsional guided wave mode. This enhances the capability of UGW flaw detection and sizing.

28 November 2017 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Open access
PLPremesh Shehan Lowe
Premesh Shehan Lowe
TSTimo Scholehwar
Timo Scholehwar
JYJimmy Yau
Jimmy Yau
JKJamil Kanfoud
Jamil Kanfoud
Tat-Hean GanTat-Hean Gan
Tat-Hean Gan
CSCem Selcuk
Cem Selcuk
the application of the fundamental shear-horizontal wave mode for guided wave structural health monitoring is undoubtedly beneficial due its non-dispersive characteristics. Existing guided wave shear mode transducers are rigid and brittle, because of these characteristics, bonding them to irregular surfaces (i.e. curved surfaces) are challenging. There is a huge market interest in the development of a flexible shear mode transducer, which eases the transducer bonding process onto irregular surfaces and improves the surface contact between the transducer and the structure. This study presents a flexible shear mode transducer for structural health monitoring using low frequency guided waves (20-120 kHz). The proposed transducer is manufactured using piezoceramic and based on the results in this study, it exhibits the directional excitation of fundamental shear-horizontal mode at 20-120 kHz. Finite element analysis and laboratory experiments were conducted to study the behavior of the proposed transducer. Field trials were conducted on a liquid storage tank with an undulated surface (due to corrosion). The performance of the proposed transducer is also compared to the commercially available Macro Fiber Composite transducers. The proposed transducer was driven by the industrialized ultrasonic guided wave inspection system; Teletest Focus+ in line with the application of tank floor inspection using ultrasonic guided waves.

19 March 2015 in IEEE Sensors Journal
Verified
Journal Article
Open access
SFSina Fateri
Sina Fateri
PLPremesh Shehan Lowe
Premesh Shehan Lowe
BEBhavin Engineer
Bhavin Engineer
NBNikolaos V. Boulgouris
Nikolaos V. Boulgouris
Ultrasonic guided waves (UGW) can be used to inspect and monitor a structure from a single test location. Piezoelectric transducers are commonly dry-coupled with force to the surface of the waveguide in order to excite UGWs. These UGWs propagating within the waveguide will interact and reflect from known features, thus possible damage could be detected. In this paper, the interaction of UGWs with piezoelectric transducers is reported and investigated. A Finite Element Analysis (FEA) approach has been used to conduct a parametric study in order to quantify the effect of the waveguide diameter on the guided wave response. Laboratory experiments are carried out to measure the effect of the force on the dry-coupled piezoelectric transducers and the corresponding guided wave response, including reflections and mode conversions. A test rig is used to apply and measure the force on the piezoelectric transducers. For verification, a 3D Laser Doppler Vibrometry (3D-LDV) scan is performed on the waveguide in order to quantitatively identify the modes of interest. The conclusions reached this paper, particularly with respect to the quantification of the wave mode properties, lead to useful recommendations which may contribute to field inspection scenarios.

3 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PLPremesh Shehan Lowe
Premesh Shehan Lowe
HLHabiba Lais
Habiba Lais
VPVeena Paruchuri
Veena Paruchuri
Tat-Hean GanTat-Hean Gan
Tat-Hean Gan
The structural integrity assessment of thermoplastic pipes has become an interesting area of research due to its elevated usage in the liquid/gas transportation industry. Ultrasonic guided wave testing has gained higher attention from industry for the inspection of elongated structures due to the reduced inspection time and cost associated with conventional non-destructive testing techniques, e.g., ultrasonic testing, radiography, and visual inspection. Current research addresses the inspection of thermoplastic pipes using ultrasonic guided waves as a low cost and permanently installed structural health-monitoring tool. Laboratory and numerical investigations were conducted to study the potential of using ultrasonic guided waves to assess the structural health of thermoplastic pipe structures in order to define optimum frequency range for inspection, array design, and length of inspection. In order to achieve a better surface contact, flexible Macro-Fiber Composite transducers were used in this investigation, and the Teletest® Focus+ system was used as the pulser/receiver. Optimum frequency range of inspection was at 15−25 kHz due to the level of attenuation at higher frequencies and the larger dead zone at lower frequencies due to the pulse length. A minimum of 14 transducers around the circumference of a 3 inch pipe were required to suppress higher order flexural modes at 16 kHz. According to the studied condition, 1.84 m of inspection coverage could be achieved at a single direction for pulse-echo, which could be improved by using a higher number of transducers for excitation and using pitch-catch configuration.

1 January 2015 in Physics Procedia
Verified
Journal Article
Open access
PLPremesh Shehan Lowe
Premesh Shehan Lowe
RSR. Sanderson
R. Sanderson
SPS.K. Pedram
S.K. Pedram
NBN.V. Boulgouris
N.V. Boulgouris
PMP. Mudge
P. Mudge
Inspection of cylindrical structures using the first longitudinal Ultrasonic Guided Wave (UGW) mode has so far been predominantly neglected. This is due to its attenuative and dispersive behaviour, at common UGW operating frequencies (20-100kHz). However, with the current knowledge on the level of attenuation in the first longitudinal wave mode and dispersion compensation techniques, the first longitudinal guided wave mode no longer need to be neglected. Furthermore, the first longitudinal guided wave mode has higher number of non-axisymmetric modes compared to other axisymmetric modes in the operating frequency. This will enhance the flaw sizing capability which makes the first longitudinal guided wave mode a viable prospect for UGW inspection of cylindrical structures. This study has been performed to investigate the potential of exciting the first longitudinal guided wave mode in isolation. Numerical investigations have been conducted to investigate the pure excitation of the first longitudinal guided wave mode. It has been shown that the first longitudinal guided wave mode can be used in UGW inspection effectively in isolation by adopting transducers with out of plane vibration for excitation. This can reduces the cost and weight of UGW inspection tooling. Numerical results are empirically validated