Timo Scholehwar

Dr. Timo Scholehwar

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2017 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Open access
PLPremesh Shehan Lowe
Premesh Shehan Lowe
TSTimo Scholehwar
Timo Scholehwar
JYJimmy Yau
Jimmy Yau
JKJamil Kanfoud
Jamil Kanfoud
Tat-Hean GanTat-Hean Gan
Tat-Hean Gan
CSCem Selcuk
Cem Selcuk
the application of the fundamental shear-horizontal wave mode for guided wave structural health monitoring is undoubtedly beneficial due its non-dispersive characteristics. Existing guided wave shear mode transducers are rigid and brittle, because of these characteristics, bonding them to irregular surfaces (i.e. curved surfaces) are challenging. There is a huge market interest in the development of a flexible shear mode transducer, which eases the transducer bonding process onto irregular surfaces and improves the surface contact between the transducer and the structure. This study presents a flexible shear mode transducer for structural health monitoring using low frequency guided waves (20-120 kHz). The proposed transducer is manufactured using piezoceramic and based on the results in this study, it exhibits the directional excitation of fundamental shear-horizontal mode at 20-120 kHz. Finite element analysis and laboratory experiments were conducted to study the behavior of the proposed transducer. Field trials were conducted on a liquid storage tank with an undulated surface (due to corrosion). The performance of the proposed transducer is also compared to the commercially available Macro Fiber Composite transducers. The proposed transducer was driven by the industrialized ultrasonic guided wave inspection system; Teletest Focus+ in line with the application of tank floor inspection using ultrasonic guided waves.

22 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
LMLorena Pardo Mata
Lorena Pardo Mata
ÁGÁlvaro García
Álvaro García
FSFranz Schubert
Franz Schubert
AKAntje Kynast
Antje Kynast
TSTimo Scholehwar
Timo Scholehwar
Jose F. BartolomeJose F. Bartolome
Jose F. Bartolome
Achieving good piezoelectric properties, such as the widely reported d33 charge coefficient, is a good starting point in establishing the potential applicability of piezoceramics. However, piezoceramics are only completely characterized by consistent piezoelectric-elastic-dielectric material coefficient matrices in complex form, i.e., including all losses. These matrices, which define the various alternative forms of the constitutive equations of piezoelectricity, are required for reliable virtual prototyping in the design of new devices. To meet this need, ten precise and accurate piezoelectric dielectric and elastic coefficients of the material, including all losses, must be determined for each alternative. Due to the difficulties arising from the coupling of modes when using the resonance method, this complete set of parameters is scarcely reported. Bi0.5Na0.5TiO3-based solid solutions are already commercially available in Europe and Japan. Here, we report a case study of the determination of these sets of material coefficients (diα, giα, eiα and hiα; sE,Dαβ and cE,Dαβ; εTik and εSik; and βTik and βSik), including all losses, of the commercial PIC700 eco-piezoceramic. Plate, disk, and cylinder ceramic resonators of a manageable aspect ratio were used to obtain all the material coefficients. The validation procedure of the matrices is also given by FEA modeling of the considered resonators.

1 June 2021 in Ceramics International
Verified
Journal Article
Closed access
MCMinkyu Choi
Minkyu Choi
YPYoonsang Park
Yoonsang Park
HDHossein Daneshpajooh
Hossein Daneshpajooh
TSTimo Scholehwar
Timo Scholehwar
EHEberhard Hennig
Eberhard Hennig
Kenji UchinoKenji Uchino
Kenji Uchino