More than half of the energy consumption in buildings is utilized for the heating and/or cooling of the indoor environment. The building envelope plays a key role in controlling the effects of external weather and, therefore, is linked with many passive design strategies. Thermal energy storage (TES) and phase change materials (PCMs) are efficient techniques, which can store a high density of thermal energy. The PCMs attract many researchers to implement them in the components of buildings for thermal management. In building walls, they were implemented in different positions and have achieved different results. This paper aims to review the related literature that examines PCMs’ application in different positions within the building walls to locate their optimum position and the influential parameters. It was found that the optimum positions of PCMs are highly dependent on performing a daily complete melting/freezing cycle to be ready for the following day. Many parameters can influence this, including climate and weather conditions and the application target, PCMs’ melting temperature and heat of fusion, PCMs’ amount, the thermal properties of the wall’s materials, a mechanical heating/cooling or free-running indoor environment, and wall orientation. An optimization process using the simulation tools is suggested so that the optimum position of the PCMs can be located.
Building sector is associated with high energy consumption and greenhouse gas emissions, which contribute to climate change. Sustainable development emphasizes any actions to reduce climate change and its effect. In Malaysia, half of the energy utilized in buildings goes towards building cooling. Thermal comfort studies and adaptive thermal comfort models reflect the high comfort temperatures for Malaysians in naturally conditioned buildings, which make it possible to tackle the difference between buildings’ indoor temperature and the required comfort temperature by using proper passive measures. This study investigates the effectiveness of building’s retrofitting with phase change materials (PCMs) as a passive cooling technology to improve the indoor thermal environment for more comfortable conditions. PCM sheets were numerically investigated below the internal finishing of the walls. The investigation involved an optimization study for the PCMs transition temperatures and quantities. The results showed significant improvement in the indoor thermal environment, especially when using lower transition temperatures and higher quantities of PCMs. Therefore, the monthly thermal discomfort time has decreased completely, while the thermal comfort time has increased to as high as 98%. The PCM was effective year-round and the optimum performance for the investigated conditions was achieved when using 18mm layer of PCM27-26.
26 April 2012 in Journal of Sustainable Development
As an alternative to air-conditioning systems, the rooftop turbine ventilator now is not only widely accepted as industrial ventilation, but also has become a common ventilation feature used in other types of buildings including institutional, commercial and residential. Although it is often thought to be very effective even in the lightest wind conditions, but many scientific studies found that its actual performance in the real building is not very promising due to some outdoor climatic constraints and the weaknesses of the device’s configuration itself. Therefore, in order to describe its full characteristics, reliability, limitations and possible improvement of the device, this paper discusses the current development and future prospects of the turbine ventilator by elaborating the results of some experimental and analytical work that have been done in various aspects of its application and performance. The analysis and summarized findings presented in this paper also recommend some criteria that should be considered in designing future turbine ventilator which is not only ventilate well in high-wind speed region, but also could be an effective multifunction device even in low wind velocity region.
31 December 2022 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
As we spend most of our time in indoor spaces, half of the energy consumption in buildings is used to improve the indoor thermal environment to achieve thermally comfortable conditions. However, studies showed that people in naturally ventilated buildings have a broader thermal comfort zone. Additionally, people in hot areas can tolerate higher indoor temperatures. Therefore, this work investigates and evaluates the indoor thermal environment and the thermal comfort level in naturally conditioned buildings. Field measurements were conducted in various residential spaces in different buildings. The measurements were used to calculate the operative temperature (Tₒₚ), which was utilized to evaluate the thermal comfort level based on the adaptive models and taking into account the effect of the various orientations. The results showed that maximum Tₒₚ ranged between 27.70 ℃ and 35.50 ℃, depending mainly on the space’s orientation. Additionally, the thermal discomfort time ranged between 0% and 73%. The South & East, Southeast, South, and East orientation were more critical during the study period, while the North, Northeast, and Northwest orientations achieved better indoor thermal conditions. However, these results can vary throughout the year, depending on the sun’s path. This study revealed that the daily average heat gain to the building from the Southeast and South orientations is higher than that from the East and West orientations due to the longer exposure time to solar radiation.
1 January 2009 in International Journal on Design and Manufacturing Technologies
An Indoor Environmental Quality (IEQ) fieldwork assessment was conducted in the Platinum-rated GBI office building located in Putrajaya Malaysia. The aim of the study is to determine the current indoor performance of the selected green office building. The field measurement consists of several IEQ parameters counted under the GBI Malaysia namely the Thermal Comfort of temperature, relative humidity, air movement and heat transfer as well as solar radiation. This field measurement also comprises of the measurement for the background noise, visual lighting and Indoor Air Quality (IAQ) focusing on the aspect of carbon dioxide concentration. All the selected indoor parameters were measured for the period of five working days and the results were compared to the Malaysian Standard. Findings of the field measurement show good indoor performance of the Platinum rated office building that complies with the GBI standard. It is hoped that the research findings will be beneficial for future design and construction of office building intended to be rated under the GBI Malaysia.