Lifetime and reliability in realistic operating conditions are important parameters for the application of thin-film piezoelectric microelectromechanical systems (piezoMEMS) based on lead zirconate titanate (PZT). Humidity can induce time-dependent dielectric breakdown at a higher rate compared to dry conditions, and significantly alter the dynamic behavior of piezoMEMS-devices. Here we assess the lifetime and reliability of PZT-based micromirrors with and without humidity barriers operated at 23°C in an ambient of 0 and 95 % relative humidity. The correlation of the dynamic response, as well as the ferroelectric, dielectric, and leakage properties, with degradation time was investigated. In humid conditions, the median time-to-failure was increased from 2.7x10⁴[1.9x10⁴-4.0x10⁴] s to 1.1x10⁶[0.9x10⁶-1.5x10⁶] s at 20 VAC continuous unipolar actuation, by using a 40 nm thick Al₂O₃ humidity barrier. However, the initial maximum angular deflection, polarization, and dielectric permittivity decreased by about 6, 11, and 12 %, respectively, for Al₂O₃ capped devices. For both bare and encapsulated devices, the onset of electrothermal breakdown-events was the dominant cause of degradation. Severe distortions in the device's dynamic behavior, together with failure from loss of angular deflection, preceded time-dependent dielectric breakdown in 95% relative humidity. Moreover, due to the film-substrate stress transfer sensitivity of thin-film devices, water-induced degradation affects the reliability of thin-film piezoMEMS differently than bulk piezoMEMS. [2020-0228]
The ambient humidity significantly accelerates the degradation of lead zirconate titanate (PZT) films in microelectromechanical systems; the cause of such degradation is under debate. Here, it is shown that the degradation of chemical solution derived PZT thin-films in humid conditions is driven by the system's electrochemical activity toward water electrolysis. The layer stacks with Pt-based electrodes exhibited a faster degradation rate owing to their higher electrocatalytic activity compared to Au. A degradation model is proposed based on the electrolysis of liquid or gaseous H2O, involving the evolution of oxygen and hydrogen gas at the top and bottom electrodes. Degradation proceeds above the threshold voltage for a given electrode system and is driven by the evolution and pressure build-up of gaseous species at the PZT/electrode interfaces. The pressure build-up causes film cracking, delamination of the film and electrodes, electrothermal breakdown events, and eventually time-dependent dielectric breakdown. Significantly larger post-breakdown crater sizes in humid than in dry conditions suggests that larger cracks through which dielectric breakdown through humidified air can occur. Overall, these effects are shown to cause sample failure up to six orders of magnitude of time earlier than for operation in dry conditions. Thus, in order to improve the resilience of thin-film systems in humid conditions, it is imperative to protect the electrochemically active electrode components of the device.
Although Pb(Zr,Ti)O3 (PZT) piezoelectric thin films are finding widespread applications on Earth, it is yet unclear if they are suitable for space-related applications. In space, their long-term reliability is a significant concern due to the difficulties of repairing and replacing malfunctioning devices. In this work, PZT thin film micromirrors for compact interferometric 3D imaging systems have been exposed to operating conditions encountered on a space mission and tested according to criteria set by the European Space Agency. Thermal cycling in vacuum, sinusoidal and random mechanical vibrations, and -radiation with and without bias did not degrade key functional device properties of the micromirror such as angular deflection, resonance frequency, polarization, and permittivity. Apart from -radiation, stressing the devices enhanced their large-signal angular deflection and improved their electrical lifetime compared to pristine devices. Their dielectric and ferroelectric characteristics remained comparable to that of a lab-scale environment. Simultaneously applying a 10 V field-down bias while -radiating the micromirrors changed the capacitance-field and polarization-field characteristics and enhanced the electrical imprint. After stress-testing, the median time-to-failure in moderate acceleration conditions of 150 kV/cm and 175 °C ranged from 1.95 to 2.64 h, close to 2.11 h as measured for a reference group. All actuator membranes had shorter electrical lifetimes, smaller voltage acceleration factors, and smaller activation energies, ranging from 2.56 to 2.88 V−1 and 1.03 to 1.09 eV, than simple bonding pads. This work is a device-level report covering a full set of space-relevant tests demonstrating that PZT-based thin film piezomicroelectromechanical systems technology is space-ready.
This paper describes the high-rate (~1.5 μm/min) growth of Si films on Si supporting substrates with (100) crystallographic orientation at 600 °C, 800 °C, and 1000 °C in a vacuum environment of ~1 × 10−5 mbar using electron beam (e-beam) evaporation. The microstructure, crystallinity, and conductivity of such films were investigated. It was established that fully crystalline (Raman spectroscopy, EBSD) and stress-free epi-Si layers with a thickness of approximately 50 µm can be fabricated at 1000 °C, while at 600 °C and 800 °C, some poly-Si inclusions were observed using Raman spectroscopy. Hall effect measurements showed that epi-Si layers deposited at 1000 °C had resistivity, carrier concentration, and mobility comparable to those obtained for c-Si wafers fabricated through ingot growth and wafering using the same solar grade Si feedstock used for the e-beam depositions. The dislocation densities were determined to be ∼2 × 107 cm−2 and ∼5 × 106 cm−2 at 800 and 1000 °C, respectively, using Secco etch. The results highlight the potential of e-beam evaporation as a promising and cost-effective alternative to conventional CVD for the growth of epi-Si layers and, potentially, epi-Si wafers. Some of the remaining technical challenges of this deposition technology are briefly indicated and discussed.
Thin-film piezoelectrics are widely investigated for actuators and energy harvesters, but there are few alternatives to toxic lead zirconate titanate. Biocompatible Ca- and Zr-modified BaTiO3 (BCZT) is one of the most promising lead-free alternatives due to its high piezoelectric response. However, the dielectric/piezoelectric properties and structural integrity of BCZT films, which are crucial for their applications, are strongly influenced by the substrate upon which the film is grown and the related processing methods. Here, the in-plane stress, microstructure, dielectric, and piezoelectric properties of 100–500 nm thick high-temperature RF-sputtered BCZT films on industrially relevant Si-based substrates were investigated. Obtaining polycrystalline piezoelectric films required deposition temperatures ≥ 700 °C, but this induced tensile stresses of over 1500 MPa, which caused cracking in all films thicker than 200 nm. This degraded the dielectric, piezoelectric, and ferroelectric properties of films with larger electrode areas for applications. Films on SrTiO3, on the other hand, had a compressive residual stress, with fewer defects and no cracks. The grain size and surface roughness increased with increasing deposition temperature. These findings highlight the challenges in processing BCZT films and their crucial role in advancing lead-free piezoelectric technologies for actual device applications.
Miniaturization of electrochemical sensors for potentiometric measurements can be made possible using microfabrication technologies. However, conventional reference electrodes are often challenging to miniaturize and integrate, limiting the compactness of the microfluidic setup for potentiometric sensors. In this study, we have developed a method for inkjet printing planar solid-state Ag/AgCl pseudo reference electrodes on a TiW-Au coated Si-based potentiometry sensor. A method for inkjet printing of pseudo reference electrodes was established for two sensor variants: planar sensors and sensors with an integrated microfluidic cell. The pseudo reference electrode in both sensor versions showed stable potentiometric readings for 70 days with standard deviation below 1 mV. Sensor potential readings using the pseudo reference electrode and conventional reference electrode were comparable, showing linearity and near Nernstian response. However, the sensors with the pseudo reference electrode showed to be less robust compared to commercial screen-printed electrodes, lasting fewer calibration cycles. Inkjet printing provides a straightforward and cost-effective method for the incorporation of pseudo-reference electrodes into miniaturized potentiometric sensors. This approach is compatible with post-processing steps following microfabrication, aiming to facilitate the development of monolithically integrated microfluidic sensors for automated on-site analysis.