Adriana de Alcantara CURY-SARAMAGO

Prof. Adriana de Alcantara CURY-SARAMAGO


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
JFJamille B Ferreira
Jamille B Ferreira
ICIlana O Christovam
Ilana O Christovam
DADavid S Alencar
David S Alencar
AMAndréa F J da Motta
Andréa F J da Motta
CMClaudia T Mattos
Claudia T Mattos
ACAdriana de Alcantara CURY-SARAMAGO
Adriana de Alcantara CURY-SARAMAGO
Objectives:The aim of this systematic review with meta-analysis was to assess the accuracy and reproducibility of dental measurements obtained from digital study models generated from CBCT compared with those acquired from plaster models.Methods:The electronic databases Cochrane Library, Medline (via PubMed), Scopus, VHL, Web of Science, and System for Information on Grey Literature in Europe were screened to identify articles from 1998 until February 2016. The inclusion criteria were: prospective and retrospective clinical trials in humans; validation and/or comparison articles of dental study models obtained from CBCT and plaster models; and articles that used dental linear measurements as an assessment tool. The methodological quality of the studies was carried out by Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. A meta-analysis was performed to validate all comparative measurements.Results:The databases search identified a total of 3160 items and 554 duplicates were excluded. Af...

1 April 2017 in Dental Press Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
JCJulia Garcia Costa
Julia Garcia Costa
TGThaís Magalhães Galindo
Thaís Magalhães Galindo
CMClaudia Trindade Mattos
Claudia Trindade Mattos
ACAdriana de Alcantara CURY-SARAMAGO
Adriana de Alcantara CURY-SARAMAGO
OBJECTIVE: The aim of this systematic review was to evaluate the duration of the retention period in growing patients undergoing maxillary expansion and its relation with posterior crossbite stability. METHODS: Search strategies were executed for electronic databases Cochrane Library, Web of Science, PubMed and Scopus, which were completed on January 15, 2016. The inclusion criteria included randomized, prospective or retrospective controlled trials in growing subjects with posterior crossbite; treated with maxillary expanders; retention phase after expansion; post-retention phase of at least 6 months. The exclusion criteria were anterior crossbite, craniofacial anomalies, surgery or another orthodontic intervention; case reports; author’s opinions articles, thesis, literature reviews and systematic reviews. The risk of bias of selected articles was assessed with Cochrane risk of bias tool for RCTs and Downs and Black checklist for non-RCTs. RESULTS: A total of 156 titles/abstracts was retrieved, 44 full-texts were examined, and 6 articles were selected and assessed for their methodological quality. The retention period after maxillary expansion ranged between 4 weeks and 16 months. Fixed (acrylic plate, Haas, Hyrax and quad-helix) or removable (Hawley and Hawley expander) appliances were used for retention. CONCLUSIONS: Six months of retention with either fixed or removable appliances seem to be enough to avoid relapse or to guarantee minimal changes in a short-term follow-up.

1 November 2017 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
JCJulia Garcia Costa
Julia Garcia Costa
GCGenilza Silva Costa
Genilza Silva Costa
CCCarolina Costa
Carolina Costa
OVOswaldo de Vasconcellos Vilella
Oswaldo de Vasconcellos Vilella
CMClaudia Trindade Mattos
Claudia Trindade Mattos
ACAdriana de Alcantara CURY-SARAMAGO
Adriana de Alcantara CURY-SARAMAGO

1 July 2009 in The Angle Orthodontist
Verified
Journal Article
Closed access
ACAdriana de Alcantara CURY-SARAMAGO
Adriana de Alcantara CURY-SARAMAGO
PCPriscila Rocha Coimbra
Priscila Rocha Coimbra
AIAntonio de Moraes Izquierdo
Antonio de Moraes Izquierdo
CECarlos Nelson Elias
Carlos Nelson Elias
ARAntônio Carlos de Oliveira Ruellas
Antônio Carlos de Oliveira Ruellas
ESEduardo Franzotti Sant'ANna
Eduardo Franzotti Sant'ANna
Objective: Verify the in vitro effectiveness of different porcelain surface polishing systems used after orthodontic debonding. Materials and Methods: Restorations were simulated by 52 metallic samples covered with glazed feldspathic porcelain. Four of these intact samples composed the control group (C). The remaining samples were divided into four groups (n = 12), according to the surface preparation they were to receive: no surface treatment (G1); roughened with a diamond bur (G2); etched with 10% hydrofluoric acid (G3); and sandblasted with aluminum oxide (G4). All experimental samples were treated with silane and bonded with a primer and standardized amount of adhesive. After composite removal, each group was divided into subgroups randomly (n = 4), according to the porcelain polishing system used: Edenta (P1); Identoflex (P2); and Komet (P3). All 52 sample-surfaces were evaluated quantitatively with a profilometer, and a mean roughness profile (Ra) value was determined for each sample. Both control and experimental specimens were evaluated qualitatively using a scanning electron microscope (SEM) to assess surface morphology. Results: Statistical analysis with analysis of variance (ANOVA) and post-hoc Tukey multiple comparisons test showed statistical differences between surface preparation groups (G1 ≠ G2 = G3 = G4), at α = .05 level of significance; as for polishing protocols, no statistical difference was found. Conclusions: The surface preparation was the determinant for final surface texture. No combination between surface preparation and polishing system was able to reestablish the original glazed porcelain smoothness.

14 March 2025 in Journal of Dentistry
Verified
Journal Article
Closed access
CMClaudia Trindade Mattos
Claudia Trindade Mattos
LDLucie Dole
Lucie Dole
SMSergio Luiz Mota-Júnior
Sergio Luiz Mota-Júnior
ACAdriana de Alcantara CURY-SARAMAGO
Adriana de Alcantara CURY-SARAMAGO
JBJonas Bianchi
Jonas Bianchi
LCLucia Helena Soares Cevidanes
Lucia Helena Soares Cevidanes

21 August 2017 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
NANina Argalji
Nina Argalji
ESEduardo Da Silva
Eduardo Da Silva
ACAdriana de Alcantara CURY-SARAMAGO
Adriana de Alcantara CURY-SARAMAGO
CMClaudia Trindade Mattos
Claudia Trindade Mattos
The objective of this study was to compare coating dimensions and surface characteristics of two different esthetic covered nickel-titanium orthodontic rectangular archwires, as-received from the manufacturer and after oral exposure. The study was designed for comparative purposes. Both archwires, as-received from the manufacturer, were observed using a stereomicroscope to measure coating thickness and inner metallic dimensions. The wires were also exposed to oral environment in 11 orthodontic active patients for 21 days. After removing the samples, stereomicroscopy images were captured, coating loss was measured and its percentage was calculated. Three segments of each wire (one as-received and two after oral exposure) were observed using scanning electron microscopy for a qualitative analysis of the labial surface of the wires. The Lilliefors test and independent t-test were applied to verify normality of data and statistical differences between wires, respectively. The significance level adopted was 0.05. The results showed that the differences between the wires while comparing inner height and thickness were statistically significant (p < 0.0001). In average, the most recently launched wire presented a coating thickness twice that of the control wire, which was also a statistically significant difference. The coating loss percentage was also statistically different (p = 0.0346) when the latest launched wire (13.27%) was compared to the control (29.63%). In conclusion, the coating of the most recent wire was thicker and more uniform, whereas the control had a thinner coating on the edges. After oral exposure, both tested wires presented coating loss, but the most recently launched wire exhibited better results.