John Grimble

Mr. John Grimble


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
GMGopi Maguluri
Gopi Maguluri
JGJohn Grimble
John Grimble
ACAliana Caron
Aliana Caron
GZGe Zhu
Ge Zhu
SKSavitri Krishnamurthy
Savitri Krishnamurthy
NINicusor Iftimia
Nicusor Iftimia
This paper presents a combined optical imaging/artificial intelligence (OI/AI) technique for the real-time analysis of tissue morphology at the tip of the biopsy needle, prior to collecting a biopsy specimen. This is an important clinical problem as up to 40% of collected biopsy cores provide low diagnostic value due to high adipose or necrotic content. Micron-scale-resolution optical coherence tomography (OCT) images can be collected with a minimally invasive needle probe and automatically analyzed using a computer neural network (CNN)-based AI software. The results can be conveyed to the clinician in real time and used to select the biopsy location more adequately. This technology was evaluated on a rabbit model of cancer. OCT images were collected with a hand-held custom-made OCT probe. Annotated OCT images were used as ground truth for AI algorithm training. The overall performance of the AI model was very close to that of the humans performing the same classification tasks. Specifically, tissue segmentation was excellent (~99% accuracy) and provided segmentation that closely mimicked the ground truth provided by the human annotations, while over 84% correlation accuracy was obtained for tumor and non-tumor classification.

26 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
CYChuwei Ye
Chuwei Ye
WLWen Li
Wen Li
Zhaojian LiZhaojian Li
Zhaojian Li
GMGopi Maguluri
Gopi Maguluri
JGJohn Grimble
John Grimble
MGMichele Grimm
Michele Grimm
Driving is a ubiquitous activity that requires both motor skills and cognitive focus. These aspects become more problematic for some seniors, who have underlining medical conditions and tend to lose some of these capabilities. Therefore, driving can be used as a controlled environment for the frequent, non-intrusive monitoring of bio-physical and cognitive status within drivers. Such information can then be utilized for enhanced assistive vehicle controls and/or driver health monitoring. In this paper, we present a novel multi-modal smart steering sleeve (S3) system with an integrated sensing platform that can non-intrusively and continuously measure a driver’s physiological signals, including electrodermal activity (EDA), electromyography (EMG), and hand pressure. The sensor suite was developed by combining low-cost interdigitated electrodes with a piezoresistive force sensor on a single, flexible polymer substrate. Comprehensive characterizations on the sensing modalities were performed with promising results demonstrated. The sweat-sensing unit (SSU) for EDA monitoring works under a 100 Hz alternative current (AC) source. The EMG signal acquired by the EMG-sensing unit (EMGSU) was amplified to within 5 V. The force-sensing unit (FSU) for hand pressure detection has a range of 25 N. This flexible sensor was mounted on an off-the-shelf steering wheel sleeve, making it an add-on system that can be installed on any existing vehicles for convenient and wide-coverage driver monitoring. A cloud-based communication scheme was developed for the ease of data collection and analysis. Sensing platform development, performance, and limitations, as well as other potential applications, are discussed in detail in this paper.

13 June 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
RSRebecca Steinberg
Rebecca Steinberg
JMJack Meehan
Jack Meehan
DTDoran Tavrow
Doran Tavrow
GMGopi Maguluri
Gopi Maguluri
JGJohn Grimble
John Grimble
NINicusor Iftimia
Nicusor Iftimia
This paper presents a combined optical coherence tomography (OCT) imaging/machine learning (ML) technique for real-time analysis of lung tissue morphology to determine the presence and level of invasiveness of idiopathic lung fibrosis (ILF). This is an important clinical problem as misdiagnosis is common, resulting in patient exposure to costly and invasive procedures and substantial use of healthcare resources. Therefore, biopsy is needed to confirm or rule out radiological findings. Videoscopic-assisted thoracoscopic wedge biopsy (VATS) under general anesthesia is typically necessary to obtain enough tissue to make an accurate diagnosis. This kind of biopsy involves the placement of several tubes through the chest wall, one of which is used to cut off a piece of lung to send for evaluation. The removed tissue is examined histopathologically by microscopy to confirm the presence and the pattern of fibrosis. However, VATS pulmonary biopsy can have multiple side effects, including inflammation, tissue morbidity, and severe bleeding, which further degrade the quality of life for the patient. Furthermore, the results are not immediately available, requiring tissue processing and analysis. Here, we report an initial attempt of using ML-assisted polarization sensitive OCT (PS-OCT) imaging for lung fibrosis assessment. This approach has been preliminarily tested on a rat model of lung fibrosis. Our preliminary results show that ML-assisted PS-OCT imaging can detect the presence of ILF with an average of 77% accuracy and 89% specificity.

1 July 2025 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
YXYinghan Xu
Yinghan Xu
SSSrikamal Soundararajan
Srikamal Soundararajan
SRScott Randell
Scott Randell
NINicusor Iftimia
Nicusor Iftimia
GMGopi Maguluri
Gopi Maguluri
AOAmy L. Oldenburg
Amy L. Oldenburg
Inhalation injury occurs from pulmonary exposure to a variety of chemicals, such as smoke, vapors, and gases.1 It constitutes a significant cause of morbidity and mortality in patients with severe burns.2 According to the Centers for Disease Control and Prevention, 398,000 burn injuries required medical treatment in 2021, resulting in 3800 deaths due to smoke inhalation.3 Inhalation injury affects the pulmonary system due to a combination of factors, including heat, hypoxemia, and the chemical effects of toxic inhalants.4 The high mortality rate associated with inhalation injury may be improved by standardized and objective diagnostic criteria. The current gold standard for diagnosing inhalation injury is flexible bronchoscopy and the use of the Abbreviated Injury Score criteria5 to determine injury severity. However, a drawback of the injury scoring system is its subjectivity, as interpretation may vary among examining physicians.6 Therefore, a more quantitative method is necessary to assess inhalation injury effectively and inform evolving strategies for burn treatment. Here, we address this need by exploring a method for endoscopic, optical coherence elastography that has the potential to quantitatively map the heterogeneous response of the airway to injury via its reduced wall compliance.

5 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
GMGopi Maguluri
Gopi Maguluri
JGJohn Grimble
John Grimble
ACAliana Caron
Aliana Caron
GZGe Zhu
Ge Zhu
SKSavitri Krishnamurthy
Savitri Krishnamurthy
NINicusor Iftimia
Nicusor Iftimia
This paper presents a combined optical imaging/artificial intelligence (OI/AI) technique for real-time analysis of tissue morphology at the tip of the biopsy needle, prior collecting a biopsy specimen. This is an important clinical problem as up to 40% of the collected biopsy cores provide low diagnostic value due to high adipose or necrotic content. Micron-scale resolution optical coherence tomography (OCT) images can be collected with a minimally invasive needle probe and automatically analyzed by a computer neural network (CNN)-based AI software. The results can be conveyed to the clinician in real-time and used to select the biopsy location more adequately. This technology was evaluated on a rabbit model of cancer. OCT images were collected with a hand-held custom-made OCT probe. Annotated OCT images were used as ground truth for AI algorithm training. The overall performance of the AI model was very close to that of the humans performing the same classification tasks. Specifically, tissue segmentation was excellent (~99% accuracy) and provided segmentation that closely mimicked ground truth provided by the human annotations, while over 83% correlation accuracy was obtained for tumor and non-tumor classification.

12 November 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
TYTiffany Yu
Tiffany Yu
SDSteve J. Davis
Steve J. Davis
MSMark Scimone
Mark Scimone
JGJohn Grimble
John Grimble
GMGopi Maguluri
Gopi Maguluri
YZYoubo Zhao
Youbo Zhao
This paper presents a technique for high sensitivity measurement of singlet oxygen luminescence generated during photodynamic therapy (PDT) and ultraviolet (UV) irradiation on skin. The high measurement sensitivity is achieved by using a computational spectroscopy (CS) approach that provides improved photon detection efficiency compared to spectral filtering methodology. A solid-state InGaAs photodiode is used as the CS detector, which significantly reduces system cost and improves robustness compared to photomultiplier tubes. The spectral resolution enables high-accuracy determination and subtraction of photosensitizer fluorescence baseline without the need for time-gating. This allows for high sensitivity detection of singlet oxygen luminescence emission generated by continuous wave light sources, such as solar simulator sources and those commonly used in PDT clinics. The value of the technology is demonstrated during in vivo and ex vivo experiments that show the correlation of measured singlet oxygen with PDT treatment efficacy and the illumination intensity on the skin. These results demonstrate the potential use of the technology as a dosimeter to guide PDT treatment and as an analytical tool supporting the development of improved sunscreen products for skin cancer prevention.