Wenjing Qiao

Wenjing Qiao


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2025 in Science Progress
Verified
Journal Article
Open access
YLYiqian Li
Yiqian Li
WQWenjing Qiao
Wenjing Qiao
FYFan Yang
Fan Yang
TZTingkun Zhou
Tingkun Zhou
HQHaoxuan Quan
Haoxuan Quan
Measuring the low carbon performance of buildings is a crucial method for achieving the construction industry's strategic goal of “double carbon.” The carbon emission factor calculation approach proposed by the IPCC is utilized to create a carbon emission calculation model for a steel-concrete composite structure bridge across its whole life cycle. The discount rate is used to determine the dynamic carbon emissions of the steel-concrete composite structural bridge, which are then compared to the static carbon emissions. The carbon strength of the bridge is evaluated using a fuzzy comprehensive technique. The application analysis is conducted on the basis of a steel-concrete composite construction bridge in Beijing. According to the findings, carbon emissions are primarily concentrated during the preparation, production, and operation of building materials. The bridge's static and dynamic carbon emissions are 103.966 and 1378.674 ktCO 2 e, respectively. After material recovery, the values are 95.141 ktCO 2 e and 1107.751 ktCO 2 e, respectively. The ratio of dynamic and static carbon emissions ranges from 7 to 34, highlighting the significance of temporal value. After recycling the components, the bridge's static carbon strength dropped from 2.565 to 2.353, while its dynamic carbon strength fell from 2.422 to 2.210, both of which were medium carbon strengths. The model proposed in this study can successfully examine the carbon emissions and strength of bridges from both environmental and economic perspectives, and it can be used to select more environmentally friendly building materials and construction methods to increase bridge efficiency. It also provides valuable data assistance for the establishment and execution of environmental protection measures, thereby promoting the industry's long-term sustainable development.

23 July 2022 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
WQWenjing Qiao
Wenjing Qiao
HZHao Zhang
Hao Zhang
Gang ZhangGang Zhang
Gang Zhang
FYFan Yang
Fan Yang
ZLZhiguo Liu
Zhiguo Liu
This paper presents an investigation on strong-acid relations between corrosion rate and corrosion time in 30 studs, dipped into 36% industrial hydrochloric acid through 0.5 h, 1 h, 2 h, 4 h, 8 h, 12 h, 24 h, 48 h, and 72 h, respectively. These corroded studs are performed tensile tests to study failure mode and stress-strain curves in studs with different corrosion time. Thereafter, a 3-D finite element is established through computer program to validate test results, and then analyze mechanical properties along with failure mode of studs exposed to strong-acid corrosion. The analysis results show that the failure mode gradually changes from ductile-damage state to brittle-damage state. The corrosion rates present a non-linear elevation with an increase of strong-acid-corrosion time. The nominal yield strength, the nominal ultimate strength, and the elongation in the corroded studs exhibit a fast-downward trend when increasing corrosion time. However, the degradation of elastic modulus turn into a slow step and the yield strength ratio in studs tends to be steady. The J-C model (Johnson-Cook Constitutive) with updated coefficients can be applied to reflect the constitutive relations in studs after strong-acid corrosion under quasi-static tension conditions. Further, this model can simulate stress flows within studs after strong-acid corrosion. This research results can provide a guide for long-lifetime construction and safe maintenance in steel structural bridge.

1 November 2022 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
PDF file
WQWenjing Qiao
Wenjing Qiao
HZHao Zhang
Hao Zhang
FYFan Yang
Fan Yang
ZLZhiguo Liu
Zhiguo Liu
This paper investigated stress flow in weathering steel Q345 after strong acid corrosion. In total, 27 specimens were immersed in 36% industrial hydrochloric acid for 0, 1, 2, 4, 8, 12, 24, 48, and 72 h, respectively. A three-dimensional noncontact laser scanner was used to measure geometric parameters of pits on the surface of the steel. The influence on ductile crack initiation in steel under the pit was investigated through tensile testing and finite-element simulation, which obtained the relationship among depth-diameter ratio, depth ratio, and stress triaxiality. Based on analysis of 65 finite-element models, the equivalent ductile fracture criterion of strong-corrosion steel per corrosion times was proposed. The results showed that the depth-to-diameter ratio of pits increased linearly with pit depth, whereas the depth ratio of pits increased nonlinearly with corrosion time extending. After 24 h of corrosion, the depth ratio of pits in weathering steel Q345 showed an inflection point where the growth rate was relatively slow. When corrosion time reached 72 h, the depth-diameter ratio and depth ratio of the maximum pit was 0.74 and 0.01, respectively. With the development of the depth-to-diameter ratio, the stress triaxiality inside corrosion steel increased; meanwhile, the equivalent plastic fracture strain decreased, which accelerated internal crack initiation. For pits in weathering steel Q345 with a depth-diameter ratio of 0.40–0.80, stress triaxiality increased from 0.56 to 1.23. Finally, the elongation of corrosion steel degraded gradually. By comparing test values, formula values, and finite-element values, fracture strain errors were all less than 5%. These data show that the equivalent ductile fracture criterion can accurately simulate the ductile degradation in weathering steel Q345 after hydrochloric-acid corrosion. The research results can provide a theoretical basis and application reference for strong-corrosion protection ways of weathering steel Q345 after hydrochloric-acid corrosion.

27 November 2024 in Buildings
Verified
Journal Article
Open access
PDF file
TZTingkun Zhou
Tingkun Zhou
WQWenjing Qiao
Wenjing Qiao
SLShoufu Li
Shoufu Li
FYFan Yang
Fan Yang
LYLi Yiqian
Li Yiqian
ZLZhuoda Li
Zhuoda Li
The corrosive environment in the western region will adversely affect the fatigue performance of bridges. In order to determine the influence of the corrosion environment in western China on the fatigue failure of bridges, this paper simulated corrosion environment characteristics in northwest China, conducted alternating corrosion and high-cycle fatigue experiments on Q420 bridge steel, and used Origin (2019b 64Bit) to fit S-N curves of specimens with different corrosion periods to study the influence of corrosion damage in western China on their fatigue properties. Based on the damage theory, the corrosion fatigue failure degree of Q420 bridge steel was analyzed, and the crack propagation law was revealed by microscopic scanning of the fracture. The findings indicate that the damage to Q420 bridge steel progressively worsens with more prolonged corrosion exposure in the deicing salt conditions of western China. The 60-day corrosion resulted in a rust rate ηs of 2.17% and a corrosion rate K of 1.413 mm/a. The fatigue life of Q420 bridge steel is significantly affected by the coupling of stress level and corrosion damage. After 60 days of corrosion, the specimen’s fatigue limit decreases by 12.28%, which accelerates the fatigue property degradation rate of the specimen. The damage index effectively represents the internal damage behavior of materials under corrosion fatigue conditions. Fatigue damage escalates as the corrosion period extends, and the number of fatigue bands decreases, with the stress corrosion threshold σth diminishing by 1.77%, 3.55%, 4.61%, and 6.38% across various corrosion durations. The research results are significant for the fatigue failure prediction and reliability analysis of Q420 bridge steel in a deicing salt corrosion environment in western China.

17 June 2023 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
WQWenjing Qiao
Wenjing Qiao
QHQihan Hu
Qihan Hu
FYFan Yang
Fan Yang
HZHaoyun Zhu
Haoyun Zhu
To study the shear bearing performance and failure mechanism of stud shear connectors after strong-corrosion, six groups of stud shear connectors were designed and then welded to the specimen. They are corroded by hydrochloric acid time for 0 h, 2 h, 12 h, 24 h, 48 h, and 72 h. Herein, the loading process, load-slip curve, shear bearing capacity, and failure mode were obtained by the push-out test. The bearing capacity formula was also proposed by the stress mechanism of 84 finite element models. The results of the study on stud shear connectors show that the shear capacity, deformation capacity and slip decrease gradually with the extension of corrosion time. Among them, the enlargement in the diameter exerts considerable influence on their shear capacity. Notwithstanding, the shear bearing capacity slightly increases with stud shear connectors lengthened. The concrete strength grade can strengthen the shear capacity. Finally, the shear bearing capacity formula, taking the reliability coefficient into account, is proposed by the exit test data of 104 stud shear connectors.

14 May 2025 in Buildings
Verified
Journal Article
Open access
PDF file
SLShoufu Li
Shoufu Li
TYTao Yu
Tao Yu
YLYang Liu
Yang Liu
YLYan Li
Yan Li
BLBo Lei
Bo Lei
YZYuyan Zhang
Yuyan Zhang
Aiming at problems such as difficulty and low efficiency in modeling complex building structures in Revit and Abaqus, Revit and Dynamo visual programming modeling were used to realize rapid parametric modeling of structures, and a Revit–Abaqus model conversion interface was developed. Based on Revit’s API modeling function and Dynamo’s visual programming function, a proton hospital structure model was quickly created, secondary development of Revit conducted on Visual Studio 2022 using C# language, the Revit model exported to a single unified management .sat file, and a corresponding Python script file conforming to Abaqus generated. The script file contained all the .sat file path and parameter information to realize the conversion of the BIM model to Abaqus 2020 finite element software. The proposed modeling method can effectively expand the application range of BIM in a proton hospital project and effectively improve the efficiency of BIM modeling technology. The Revit–Abaqus model conversion interface developed can realize the automatic conversion of a BIM model to a structural analysis model. Compared with the traditional finite element modeling method, this effectively improves the modeling efficiency of structural analysis of proton hospital engineering and makes up for the shortcomings of BIM technology in structural analysis of proton hospital construction.