The main aim of this work is to study the effect of the sampling rate of the photoplethysmographic (PPG) signal for pulse rate variability (PRV) analysis. Forehead and finger PPG signals were recorded at 1000 Hz during a rest state, with red and infrared wavelengths, simultaneously with the electrocardiogram (ECG). The PPG sampling rate has been reduced by decimation, obtaining signals at 500 Hz, 250 Hz, 125 Hz, 100 Hz, 50 Hz and 25 Hz. Five fiducial points were computed: apex, up-slope, medium, line-medium and medium interpolate point. The medium point is located in the middle of the up-slope of the pulse. The medium interpolate point is a new proposal as fiducial point that consider the abrupt up-slope of the PPG pulse, so it can be recovered by linear interpolation when the sampling rate is reduced. The error performed in the temporal location of the fiducial points was computed. Pulse period time interval series were obtained from all PPG signals and fiducial points, and compared with the RR intervals obtained from the ECG. Heart rate variability and PRV signals were estimated and classical time and frequency domain indices were computed. The results showed that the medium interpolate point of the PPG pulse was the most accurate fiducial point under different PPG morphologies and sensor locations, when sampling rate was reduced. Being able to reduce the sampling rate to 50 Hz without causing significant changes in time and frequency indices, when medium interpolate point was used as fiducial point.
25 January 2018 in IEEE Journal of Biomedical and Health Informatics
The main aim of this paper was to characterize the Autonomic Nervous System response in hyperbaric environments using electrocardiogram (ECG) and pulse-photoplethysmogram (PPG) signals. To that end, 26 subjects were introduced into a hyperbaric chamber and five stages with different atmospheric pressures (1 atm; descent to 3 and 5 atm; ascent to 3 and 1 atm) were recorded. Respiratory information was extracted from the ECG and PPG signals and a combined respiratory rate was studied. This information was also used to analyze Heart Rate Variability (HRV) and Pulse Rate Variability (PRV). The database was cleaned by eliminating those cases where the respiratory rate dropped into the low frequency band (LF: 0.04-0.15 Hz) and those in which there was a discrepancy between the respiratory rates estimated using the ECG and PPG signals. Classical temporal and frequency indices were calculated in such cases. The ECG results showed a time-related dependency, with the heart rate and sympathetic markers (normalized power in LF and LF/HF ratio) decreasing as more time was spent inside the hyperbaric environment. A dependence between the atmospheric pressure and the parasympathetic response, as reflected in the high-frequency band power (HF: 0.15-0.40 Hz), was also found, with power increasing with atmospheric pressure. The combined respiratory rate also reached a maximum in the deepest stage; thus, highlighting a significant difference between this stage and the first one. The PPG data gave similar findings and also allowed the oxygen saturation to be computed; therefore, we propose the use of this signal for future studies in hyperbaric environments.
An evaluation of the location of the photoplethysmogram (PPG) sensor for respiratory rate estimation is performed. Finger PPG, forehead PPG, and respiratory signal were simultaneously recorded from 35 subjects while breathing spontaneously, and during controlled respiration experiments at a constant rate from 0.1 Hz to 0.6 Hz, in 0.1 Hz steps. Four PPG-derived respiratory (PDR) signals were extracted from each one of the recorded PPG signals: pulse rate variability (PRV), pulse width variability, pulse amplitude variability and the respiratory-induced intensity variability (RIIV). Respiratory rate was estimated from each one of the four PDR signals for both PPG sensor locations. In addition, different combinations of PDR signals, power distribution of the respiratory frequency range and differences of the morphological parameters extracted from both PPG signals have been analysed. Results show better performance in terms of successful estimation and relative error when: (i) PPG signal is recorded in the finger; (ii) the respiratory rate is less than 0.4 Hz; (iii) RIIV signal is not considered. Furthermore, lower spectral power around the respiratory rate in the PDR signals recorded from the forehead was observed. These results suggest that respiratory rate estimation is better at lower rates (0.4 Hz and below) and that the finger is better than the forehead to estimate respiratory rate.
19 November 2018 in IEEE Journal of Biomedical and Health Informatics
Our long-term goal is the development of an automatic identifier of attentional states. In order to accomplish it, we should first be able to identify different states based on physiological signals. So, the first aim of this paper is to identify the most appropriate features to detect a subject's high performance state. For that, a database of electrocardiographic (ECG) and photoplethysmographic (PPG) signals is recorded in two unequivocally defined states (rest and attention task) from up to 50 subjects as a sample of the population. Time and frequency parameters of heart/pulse rate variability have been computed from the ECG/PPG signals, respectively. Additionally, the respiratory rate has been estimated from both signals and also six morphological parameters from PPG. In total, 26 features are obtained for each subject. They provide information about the autonomic nervous system and the physiological response of the subject to an attention demand task. Results show an increase of sympathetic activation when the subjects perform the attention test. The amplitude and width of the PPG pulse were more sensitive than the classical sympathetic markers ( $P_{\text{LFn}}$ and $R_{\text{LF/HF}}$ ) for identifying this attentional state. State classification accuracy reaches a mean of $\text{89} \pm \text{2}\%$ , a maximum of $\text{93}\%$ , and a minimum of $85\%$ , in the 100 classifications made by only selecting four parameters extracted from the PPG signal (pulse amplitude, pulsewidth, pulse downward slope, and mean pulse rate). These results suggest that attentional states could be identified by PPG.
4 August 2009 in Ophthalmic and Physiological Optics