13 April 2016 in IEEE Journal of Biomedical and Health Informatics
Respiratory rate and heart rate variability (HRV) are studied as stress markers in a database of young healthy volunteers subjected to acute emotional stress, induced by a modification of the Trier Social Stress Test. First, instantaneous frequency domain HRV parameters are computed using time-frequency analysis in the classical bands. Then, the respiratory rate is estimated and this information is included in HRV analysis in two ways: 1) redefining the high-frequency (HF) band to be centered at respiratory frequency; 2) excluding from the analysis those instants where respiratory frequency falls within the low-frequency (LF) band. Classical frequency domain HRV indices scarcely show statistical differences during stress. However, when including respiratory frequency information in HRV analysis, the normalized LF power as well as the LF/HF ratio significantly increase during stress (p-value <; 0.05 according to the Wilcoxon test), revealing higher sympathetic dominance. The LF power increases during stress, only being significantly different in a stress anticipation stage, while the HF power decreases during stress, only being significantly different during the stress task demanding attention. Our results support that joint analysis of respiration and HRV obtains a more reliable characterization of autonomic nervous response to stress. In addition, the respiratory rate is observed to be higher and less stable during stress than during relax (p-value <; 0.05 according to the Wilcoxon test) being the most discriminative index for stress stratification (AUC = 88.2%).
3 December 2018 in IEEE Journal of Biomedical and Health Informatics
Objective: This paper proposes an approach to better estimate the sympathovagal balance (SB) and the respiratory sinus arrhythmia (RSA) after separating respiratory influences from the heart rate (HR). Methods: The separation is performed using orthogonal subspace projections and the approach is first tested using simulated HR and respiratory signals with different spectral properties. Then, RSA and SB are estimated during autonomic blockade and stress using the proposed approach and the classical heart rate variability (HRV) analysis. Both real and ECG-derived respiration (EDR) are used and the reliability of the EDR is evaluated. Results: Mean absolute percentage errors lower than 1% were obtained after removing previously known respiratory signals from simulated HR. The proposed indices were able to improve the quantification of SB during autonomic withdrawal. In the stress data, differences ( $p < 0.003 ) among relaxed and stressful phases were found with the proposed approach, using both the real respiration and the EDR, but they disappeared when using the classical HRV. Conclusion: A better assessment of the autonomic nervous system' response to pharmacological blockade and stress can be achieved after removing respiratory influences from HR, and this can be done using either the real respiration or the EDR. Significance: This work can be used to better identify vagal withdrawal and increased sympathetic activation when the classical HRV analysis fails due to the respiratory influences on HR. Furthermore, it can be computed using only the ECG, which is an advantage when developing wearable systems with limited number of sensors.
26 July 2021 in IEEE Journal of Biomedical and Health Informatics
The main aim of this work is to study the effect of the sampling rate of the photoplethysmographic (PPG) signal for pulse rate variability (PRV) analysis. Forehead and finger PPG signals were recorded at 1000 Hz during a rest state, with red and infrared wavelengths, simultaneously with the electrocardiogram (ECG). The PPG sampling rate has been reduced by decimation, obtaining signals at 500 Hz, 250 Hz, 125 Hz, 100 Hz, 50 Hz and 25 Hz. Five fiducial points were computed: apex, up-slope, medium, line-medium and medium interpolate point. The medium point is located in the middle of the up-slope of the pulse. The medium interpolate point is a new proposal as fiducial point that consider the abrupt up-slope of the PPG pulse, so it can be recovered by linear interpolation when the sampling rate is reduced. The error performed in the temporal location of the fiducial points was computed. Pulse period time interval series were obtained from all PPG signals and fiducial points, and compared with the RR intervals obtained from the ECG. Heart rate variability and PRV signals were estimated and classical time and frequency domain indices were computed. The results showed that the medium interpolate point of the PPG pulse was the most accurate fiducial point under different PPG morphologies and sensor locations, when sampling rate was reduced. Being able to reduce the sampling rate to 50 Hz without causing significant changes in time and frequency indices, when medium interpolate point was used as fiducial point.
25 January 2018 in IEEE Journal of Biomedical and Health Informatics
The main aim of this paper was to characterize the Autonomic Nervous System response in hyperbaric environments using electrocardiogram (ECG) and pulse-photoplethysmogram (PPG) signals. To that end, 26 subjects were introduced into a hyperbaric chamber and five stages with different atmospheric pressures (1 atm; descent to 3 and 5 atm; ascent to 3 and 1 atm) were recorded. Respiratory information was extracted from the ECG and PPG signals and a combined respiratory rate was studied. This information was also used to analyze Heart Rate Variability (HRV) and Pulse Rate Variability (PRV). The database was cleaned by eliminating those cases where the respiratory rate dropped into the low frequency band (LF: 0.04-0.15 Hz) and those in which there was a discrepancy between the respiratory rates estimated using the ECG and PPG signals. Classical temporal and frequency indices were calculated in such cases. The ECG results showed a time-related dependency, with the heart rate and sympathetic markers (normalized power in LF and LF/HF ratio) decreasing as more time was spent inside the hyperbaric environment. A dependence between the atmospheric pressure and the parasympathetic response, as reflected in the high-frequency band power (HF: 0.15-0.40 Hz), was also found, with power increasing with atmospheric pressure. The combined respiratory rate also reached a maximum in the deepest stage; thus, highlighting a significant difference between this stage and the first one. The PPG data gave similar findings and also allowed the oxygen saturation to be computed; therefore, we propose the use of this signal for future studies in hyperbaric environments.
1 September 2019 in Physiological Measurement
An evaluation of the location of the photoplethysmogram (PPG) sensor for respiratory rate estimation is performed. Finger PPG, forehead PPG, and respiratory signal were simultaneously recorded from 35 subjects while breathing spontaneously, and during controlled respiration experiments at a constant rate from 0.1 Hz to 0.6 Hz, in 0.1 Hz steps. Four PPG-derived respiratory (PDR) signals were extracted from each one of the recorded PPG signals: pulse rate variability (PRV), pulse width variability, pulse amplitude variability and the respiratory-induced intensity variability (RIIV). Respiratory rate was estimated from each one of the four PDR signals for both PPG sensor locations. In addition, different combinations of PDR signals, power distribution of the respiratory frequency range and differences of the morphological parameters extracted from both PPG signals have been analysed. Results show better performance in terms of successful estimation and relative error when: (i) PPG signal is recorded in the finger; (ii) the respiratory rate is less than 0.4 Hz; (iii) RIIV signal is not considered. Furthermore, lower spectral power around the respiratory rate in the PDR signals recorded from the forehead was observed. These results suggest that respiratory rate estimation is better at lower rates (0.4 Hz and below) and that the finger is better than the forehead to estimate respiratory rate.
1 February 2022 in Computer Methods and Programs in Biomedicine