X-ray fluorescence (XRF) analysis by portable spectrometers has long been applied to the study of ancient metal artefacts. On one hand, its effectiveness depends on its ability to provide answers to archaeological, historical and technological questions. On the other hand, the artistic and monetary value of artefacts requires mandatorily respecting the physical integrity of the objects in most cases. These two conditions – i.e. being non-destructive and, at the same time, capable of significant results – affect the designing of spectrometer, with special attention given to the balance between portability and analytical performance, as well as measurement strategy. This paper presents a critical discussion concerning the use of portable XRF devices in the investigation of ancient metal artefacts, including the advantages and limitations of different technical solutions and measurement strategies. Measuring the absolute composition of the objects often requires the removal of the patina, which is seldom permitted for ancient artefacts. Hence, emphasis is given to alternative methods that are more respectful of artefact integrity and are able to make the most of the non-destructivity and measurement speed, which are the real mainstays of portable XRF. Other uses of this technique such as the analysis of multilayered materials and the study of surface compositional changes are also discussed.
X-ray fluorescence spectroscopy is a non-destructive technique employed for elemental analysis of a wide range of materials. Its advantages are especially valued in archaeometry, where portable instruments are available. Considering ancient glass, such instruments allow for the detection of some major, minor, and trace elements linked to the deliberate addition of specific components or to impurities in the raw materials of the glass batch. Besides some undoubted advantages, portable XRF (p-XRF) has some limitations that are addressed in this study. The performance assessment of four different p-XRF units and the reconciling of their output were conducted. The results show the limitations in cross-referencing the data obtained from each unit and suggest procedures to overcome the issues. The p-XRF units were tested on the set of Corning reference glasses and on a small set of archaeological glasses with known composition. The compatibility of the output was assessed using multivariate statistical tools. Such a workflow allows us to consider data from multiple sources in the same frame of reference.