The 4-leg inverter can adjust the load current or output voltage even under unbalanced load conditions, but it is known that the additional switch arm to the 3-leg inverter can increase the overall cost and the failure rate. This paper aims to analyze the failure rate and mean time between failures (MTBF) of 3-leg inverters and 4-leg inverters using part count failure analysis (PCA) and fault-tree analysis (FTA), and to compare the price of the inverters. The FTA can analyze the failure rate, including the type, number and connection status of the circuit components, and moreover the redundancy effect of the 4-leg inverter. For more accurate failure-rate prediction, the failure rate and MTBF of the 4-leg inverter according to the lifecycle of the controller are analyzed. Finally, by comparing the price of 3-leg inverters and 4-leg inverters using the cost model of major parts, the degree of reliability improvement against price increase is quantitatively analyzed.
Clamped-single submodule (CSSM) has DC short circuit current protection function to improve the safety and stability of high voltage, direct current (HVDC) system. In order to carry out the protection, it needs an additional number of insulated gate bipolar transistors (IGBTs) and diodes compared to the conventional half-bridge submodule (HBSM). In general, the failure rate tends to increase in proportion to the number of circuit components. Also, complex operation of the submodule may increase the failure rate, so accurate reliability analysis considering these points is required to apply CSSM in a practical HVDC system. We estimate the failure rate and the mean time between failures (MTBF) of CSSM using a fault tree. Fault-tree analysis (FTA) is possible to analyze the failure rate more accurately than the prior part count failure analysis (PCA) that considers only the number of parts, the type of parts, and the connection status of each circuit component. To provide guidelines for submodule selection under various conditions, we compare the economic cost of a CSSM with HBSM, FBSM, and clamped-double submodule (CDSM), and analyze the failure rate according to the voltage margin of the parts.
In this paper, we analyzed the output voltage imbalance and the cause of the offset voltage in 3-phase 3-leg inverters by using Millman’s theory. Based on this result, we proposed a voltage imbalance compensation algorithm using the dc offset voltage that appeared at the neutral point voltage of the load. To apply the proposed imbalance compensation algorithm, it needs a circuit structure of 3-phase 4-wire such as split dc-link capacitor 3-leg inverter and 4-leg inverter. Therefore, the total harmonic distortion (THD) of the load phase current according to the imbalance rate of the load was analyzed for the two inverters. Then, PSIM simulation and experiments based on a 10 kW-prototype of split dc-link capacitor 3-leg inverter were implemented to verify the validity of the proposed imbalance compensation algorithm.
26 October 2020 in Journal of Electrical Engineering & Technology
An improved hybrid submodule employs a direct current (DC) short current protection function to improve the reliability of a high-voltage direct current (HVDC) system. However, it increases the number of circuit components to implement the protection. So, we need to evaluate the relationship between the protection function and the increased number of circuit components to assess whether the improved hybrid submodule (IHSM) is suitable to practical application or not from the viewpoint of reliability. Although conventional part count failure analysis considers the type and the number of parts, it cannot reflect the operational characteristics of the submodule. To overcome this problem, we design a fault tree that reflects the operational characteristics of IHSM and calculates the failure rate by using MIL-HDBK-217F. By part count failure analysis (PCA) and fault-tree analysis (FTA), we prove the high reliability of IHSM compared to half-bridge, full-bridge, and clamped-double submodules.
An effective dead-time control strategy for the three-phase dual active bridge (3P-DAB) converter of a distribution system is studied to reduce the switching losses of power switches and improve the under-light-load power conversion efficiency. Because of the advantages of a dual-active bridge converter, such as an inherent zero-voltage switching (ZVS) capability without any additional resonant tank and a seamless bi-directional power transition, this is an attractive topology for bi-directional application. The 3P-DAB converter is apt for high-power applications such as aircraft due to an interleaved structure, which can reduce conduction losses. However, the design of the dead time depends on engineering experience and empirical methods. In order to overcome the conventional practicality of the dead-time design method, the effective control of dead time is proposed based on the theoretical analysis. In this paper, the overall explanation of the 3P-DAB converter is shown with operation principles. In addition, the dead-time effect of the 3P-DAB converter is examined and the practical variable dead-time control strategy is studied. Finally, experimental results validate the proposed variable dead-time control strategy using a 25 kW prototype 3P-DAB converter.