Raffaele Iorio

Prof. Raffaele Iorio

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Ferdinando IannottiFerdinando Iannotti
Ferdinando Iannotti
PPPaolo Prati
Paolo Prati
Andrea FidanzaAndrea Fidanza
Andrea Fidanza
RIRaffaele Iorio
Raffaele Iorio
AFAndrea Ferretti
Andrea Ferretti
Pier Francesco IndelliPier Francesco Indelli
Pier Francesco Indelli
Background: Periprosthetic joint infection (PJI) represents 25% of failed total knee arthroplasties (TKA). The European Knee Associates (EKA) formed a transatlantic panel of experts to perform a literature review examining patient-related risk factors with the objective of producing perioperative recommendations in PJI high-risk patients. Methods: Multiple databases (Pubmed/MEDLINE, EMBASE, Scopus, Cochrane Library) and recommendations on TKA PJI prevention measures from the International Consensus Meetings on PJI from the AAOS and AAHKS were reviewed. This represents a Level IV study. Results: Strong evidence was found on poor glycemic control, obesity, malnutrition, and smoking being all associated with increased rates of PJI. In the preoperative period, patient optimization is key: BMI < 35, diet optimization, Hemoglobin A1c < 7.5, Fructosamine < 292 mmol/L, smoking cessation, and MRSA nasal screening all showed strong evidence on reducing PJI risk. Intraoperatively, a weight-based antibiotic prophylaxis, accurate fluid resuscitation, betadine and chlorhexidine dual skin preparation, diluted povidone iodine solution irrigation, tranexamic acid administration, and monofilament barbed triclosan-coated sutures for soft tissues closure all represented effective prevention measures. In the postoperative period, failure to reach normalization of ESR, CRP, D-dimer, and IL-6 six weeks postoperatively suggested early PJI. Conclusion: The current recommendations from this group of experts, based on published evidence, support risk stratification to identify high-risk patients requiring implementation of perioperative measures to reduce postoperative PJI.

14 March 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ASAttilio Speranza
Attilio Speranza
CMCARLO MASSAFRA
CARLO MASSAFRA
SPStefano Pecchia
Stefano Pecchia
RNRiccardo Di Niccolo
Riccardo Di Niccolo
RIRaffaele Iorio
Raffaele Iorio
AFAndrea Ferretti
Andrea Ferretti
Metallic cerclage cables are reliable and cost-effective internal fixation devices, which are largely used in surgical practice for the treatment of periprosthetic fractures. Nevertheless, complications connected with their use have been described in the literature, including the following: third-body generation, failure and consequent migration, fraying, allergies, and injury to the surgical team. The development of new materials offers alternatives to traditional metallic cables. This study compares the outcomes between two groups of patients affected by periprosthetic hip fractures, treated with titanium cables or with ultra-high-molecular-weight polyethylene (UHMWPe) iso-elastic cables. Our retrospective study aims to compare the clinical and radiological outcomes of titanium cables and UHMWPe iso-elastic cables, isolated or associated with dedicated plates, for the surgical treatment of periprosthetic fractures with stable implants. Two groups of 30 (group A—metallic cables) and 24 (group B—UHMWPe iso-elastic cables) patients have been surgically treated in our institution for hip periprosthetic fractures, between September 2017 and June 2020. The mean age of the patients was 81 years in group A and 80 years in group B. In our study, we included fractures classified as B1 or C, according to the Vancouver postoperative fractures classification; the patients were evaluated retrospectively at 1 year postoperatively, regarding the following: surgery time, blood loss, partial weight-bearing time, radiographical healing time, Harris hip score, and postoperative complications. Comparable outcomes were observed in patients from both groups. Group A showed a higher complication rate compared to group B, at 1 year postoperatively. Non-metallic nylon fiber and ultra-high-molecular-weight polyethylene (UHMWPe) cerclage cables could represent a reliable fixation device, ensuring comparable healing and complication rates with traditional titanium cerclage cables.

20 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AFAndrea Ferretti
Andrea Ferretti
Ferdinando IannottiFerdinando Iannotti
Ferdinando Iannotti
LPLorenzo Proietti
Lorenzo Proietti
CMCARLO MASSAFRA
CARLO MASSAFRA
ASAttilio Speranza
Attilio Speranza
RIRaffaele Iorio
Raffaele Iorio
The functional positioning of components in a total hip arthroplasty (THA) and its relationship with individual lumbopelvic kinematics and a patient’s anatomy are being extensively studied. Patient-specific kinematic planning could be a game-changer; however, it should be accurately delivered intraoperatively. The main purpose of this study was to verify the reliability and accuracy of a patient-specific instrumentation (PSI) and laser-guided technique to replicate preoperative dynamic planning. Thirty-six patients were prospectively enrolled and received dynamic hip preoperative planning based on three functional lateral spinopelvic X-rays and a low dose CT scan. Three-dimensional (3D) printed PSI guides and laser-guided instrumentation were used intraoperatively. The orientation of the components, osteotomy level and change in hip length and offset were measured on postoperative CT scans and compared with the planned preoperative values. The length of surgery was compared with that of a matched group of thirty-six patients who underwent a conventional THA. The mean absolute deviation from the planned inclination and anteversion was 3.9° and 4.4°, respectively. In 92% of cases, both the inclination and anteversion were within +/− 10° of the planned values. Regarding the osteotomy level, offset change and limb length change, the mean deviation was, respectively, 1.6 mm, 2.6 mm and 2 mm. No statistically significant difference was detected when comparing the planned values with the achieved values. The mean surgical time was 71.4 min in the PSI group and 60.4 min in the conventional THA group (p < 0.05). Patient-specific and laser-guided instrumentation is safe and accurately reproduces dynamic planning in terms of the orientation of the components, osteotomy level, leg length and offset. Moreover, the increase in surgical time is negligible.

24 October 2023 in Prosthesis
Verified
Journal Article
Open access
PDF file
LPLeonardo Previ
Leonardo Previ
EVEdoardo Viglietta
Edoardo Viglietta
VGVeronica Giuliani
Veronica Giuliani
FCFederico Corsetti
Federico Corsetti
ARAndrea Redler
Andrea Redler
RIRaffaele Iorio
Raffaele Iorio
Obtaining a proper position for total hip arthroplasty components is a crucial aspect of implant performance and consequently of patient outcomes. Restoring the original hip center and maintaining the limb length are key factors in reaching the optimal implant positioning. The aim of this study was to assess the accuracy and safety of a computed dynamic analysis system that, through patient-specific guides, tries to improve implant positioning and functional orientation according to patients’ spinopelvic mobility and anatomy. A total of 100 consecutive patients were prospectively enrolled. All patients received an Optimized Positioning System dynamic hip preoperative planning schedule. A CT scan protocol follow-up analysis was performed 6 months after surgery. The mean deviations from the planned acetabular inclination and anteversion were 4.3° and 3.8°, respectively. In total, 98% of cases were within ± 10° of the Lewinnek safe zone, both for inclination and anteversion. The height of osteotomy deviated, on average, 1.6 mm. In total, 100% of cases were included within 4 mm of osteotomy. Patient-specific and laser-guided instrumentation was found to be safe and accurately reproduced dynamic planning in terms of the component orientation, osteotomy level, leg length and offset.

1 January 2007 in HIP International
Verified
Journal Article
Open access
ASA. Speranza
A. Speranza
RIRaffaele Iorio
Raffaele Iorio
MFM. Ferretti
M. Ferretti
CDC. D'Arrigo
C. D'Arrigo
AFA. Ferretti
A. Ferretti
Minimally invasive surgery has become a trend over the last few years in all aspects of orthopaedic surgery, including total hip arthroplasty So-called “mini-incision” techniques involve limiting the length of the skin incision to ≤ 10 cm with use of either an anterior, lateral or posterior approach. Between March 2004 and December 2005 one hundred consecutive unilateral total hip replacements were performed by the same senior surgeon in our institute. All patients were randomly assigned to study group (group A) or control group (group B). In group A (50 patients) the skin incision was ≤ 8 cm; in group B (50 patients) the skin incision was standard (about 12–14 cm). Patient demographic data, including sex, age, height, weight, BMI, diagnosis and preoperative Harris hip score were recorded. Other criteria evaluated included the perioperative and postoperative complications, the surgical time, the blood loss, the length of the incision, the acetabular and stem positions, the length of hospital stay, Harris Hip Score (HHS) and the WOMAC osteoarthritis index at six months. No significant differences were found between the groups with respect to the average surgical time, the acetabular and stem position, the length of hospital stay and the Harris Hip Score (HHS) and the WOMAC osteoarthritis index at six months. A significant lower blood loss was found in the mini-incision group. A higher percentage of peri-operative complications was recorded in Group A (two stupor of sciatic nerve and one fracture of the greater trochanter). On the basis of our experience we could speculate that minimally invasive surgery should be directed to the new surgical approach with muscle sparing, instead of a shorter skin incision using standard approaches.

23 September 2024 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
RIRaffaele Iorio
Raffaele Iorio
MCMatteo Romano Cantagalli
Matteo Romano Cantagalli
EVEdoardo Viglietta
Edoardo Viglietta
FCFederico Corsetti
Federico Corsetti
YGYuri Gugliotta
Yuri Gugliotta
Nicola MaffulliNicola Maffulli
Nicola Maffulli
Introduction: Heterotopic ossifications (HO) are common after total hip arthroplasty (THA). The invasiveness of surgical approaches plays a relevant role in HO development. The aims of this study were to assess the development of HO 6 months after THA through direct lateral approach (DLA) or direct anterior approach (DAA) without a dedicated orthopaedic table and to assess the clinical impact of HO. Methods: This is a single-center IRB-approved, quasi-randomized prospective cohort, observational imaging study. Fifty patients underwent primary THA through DLA and 50 through DAA. Age, sex, BMI and side of the affected hip were collected. At the 6 post-operative month the Harris Hip Score (HHS) and the presence of HO (scored through the Brooker classification system) were assessed. Results: There was no significant difference in the demographic data between groups. Operative time was significantly higher in the DAA group (72 ± 10 min vs. 58 ± 8 min: p < 0.03). At 6 post-operative months the incidence of HO was 14% in the DAA group and 32% in the DLA group (p = 0.02). Severe HO (Brooker 3–4) were significantly more common in the DLA group (p = 0.04). There was no significant difference in the HHS of patients with HO between the DAA and DLA groups. There was no association between poorer clinical outcomes and the severity of HO. Conclusion: The DAA without a dedicated orthopaedic table is associated with a significant lower incidence of HO than the DLA 6 months after elective THA. Except for the surgical approach, no other factors correlated with the occurrence of HO. Even though a lower HHS was found with severe HO, the correlation between severity of HO and clinical outcomes did not reach statistical significance.