Metallic cerclage cables are reliable and cost-effective internal fixation devices, which are largely used in surgical practice for the treatment of periprosthetic fractures. Nevertheless, complications connected with their use have been described in the literature, including the following: third-body generation, failure and consequent migration, fraying, allergies, and injury to the surgical team. The development of new materials offers alternatives to traditional metallic cables. This study compares the outcomes between two groups of patients affected by periprosthetic hip fractures, treated with titanium cables or with ultra-high-molecular-weight polyethylene (UHMWPe) iso-elastic cables. Our retrospective study aims to compare the clinical and radiological outcomes of titanium cables and UHMWPe iso-elastic cables, isolated or associated with dedicated plates, for the surgical treatment of periprosthetic fractures with stable implants. Two groups of 30 (group A—metallic cables) and 24 (group B—UHMWPe iso-elastic cables) patients have been surgically treated in our institution for hip periprosthetic fractures, between September 2017 and June 2020. The mean age of the patients was 81 years in group A and 80 years in group B. In our study, we included fractures classified as B1 or C, according to the Vancouver postoperative fractures classification; the patients were evaluated retrospectively at 1 year postoperatively, regarding the following: surgery time, blood loss, partial weight-bearing time, radiographical healing time, Harris hip score, and postoperative complications. Comparable outcomes were observed in patients from both groups. Group A showed a higher complication rate compared to group B, at 1 year postoperatively. Non-metallic nylon fiber and ultra-high-molecular-weight polyethylene (UHMWPe) cerclage cables could represent a reliable fixation device, ensuring comparable healing and complication rates with traditional titanium cerclage cables.
Obtaining a proper position for total hip arthroplasty components is a crucial aspect of implant performance and consequently of patient outcomes. Restoring the original hip center and maintaining the limb length are key factors in reaching the optimal implant positioning. The aim of this study was to assess the accuracy and safety of a computed dynamic analysis system that, through patient-specific guides, tries to improve implant positioning and functional orientation according to patients’ spinopelvic mobility and anatomy. A total of 100 consecutive patients were prospectively enrolled. All patients received an Optimized Positioning System dynamic hip preoperative planning schedule. A CT scan protocol follow-up analysis was performed 6 months after surgery. The mean deviations from the planned acetabular inclination and anteversion were 4.3° and 3.8°, respectively. In total, 98% of cases were within ± 10° of the Lewinnek safe zone, both for inclination and anteversion. The height of osteotomy deviated, on average, 1.6 mm. In total, 100% of cases were included within 4 mm of osteotomy. Patient-specific and laser-guided instrumentation was found to be safe and accurately reproduced dynamic planning in terms of the component orientation, osteotomy level, leg length and offset.
Obtaining a proper position for THA’s components is a crucial aspect for the implant perfor-mance and consequently patient outcomes. Patient specific kinematic seems to be a key factor to reach the optimal implant positioning. The aim of this study was to assess the accuracy and safety of a computed dynamic analysis system which through patient specific guides tries to improve implant positioning and functional orientation according to patient’s spinopelvic mobility and anatomy.A total of 100 consecutive patients were prospectively enrolled. All patients received an OPS dynamic hip preoperative planning. A TC scan protocol follow up analysis has done at 6 month after surgery.The mean deviation from the planned acetabular inclination and anteversion was 4.3° e 3.8° respectively. The 98% of cases was within +/- 10° of Lewinnek safe zone both for inclination and anterversion. The height of osteotomy deviated on the average of 1.6mm. The 100% cases were included within 4mm of osteotomy. Patient specific and laser guided instru-mentation is safe and accurately reproduce the dynamic planning in terms of components orien-tation, osteotomy level, leg length and offset.