Small-angle X-ray photon correlation spectroscopy (XPCS) measurements spanning delay times from 826 ns to 52.8 s were performed using a photon-counting pixel array detector with a dynamic range of 0–3 (2 bits). Fine resolution and a wide dynamic range of time scales was achieved by combining two modes of operation of the detector: (i) continuous mode, where data acquisition and data readout are performed in parallel with a frame acquisition time of 19.36 µs, and (ii) burst mode, where 12 frames are acquired with frame integration times of either 2.56 µs frame−1or 826 ns frame−1followed by 3.49 ms or 1.16 ms, respectively, for readout. The applicability of the detector for performing multi-speckle XPCS was demonstrated by measuring the Brownian dynamics of 10 nm-radius gold and 57 nm-radius silica colloids in water at room temperature. In addition, the capability of the detector to faithfully record one- and two-photon counts was examined by comparing the statistical distribution of photon counts with expected probabilities from the negative binomial distribution. It was found that in burst mode the ratio of 2 s to 1 s is markedly smaller than predicted and that this is attributable to pixel-response dead-time.
This brief presents a single-electron injection device for position-based charge qubit structures implemented in 22 nm FD-SOI CMOS. Quantum dots are implemented in local well areas separated by tunnel barriers controlled by gate terminals overlapping with a thin 5 nm undoped silicon film. Interface of the quantum structure with classical electronic circuitry is provided with single-electron transistors that feature doped wells on the classic side. A small 0.7×0.4 μm elementary quantum core is co-located with control circuitry inside the quantum operation cell which is operating at 3.5 K and a 2 GHz clock frequency. With this apparatus, we demonstrate a single electron injection into a quantum dot.
21 February 2018 in Journal of Synchrotron Radiation
The UFXC32k is a single photon counting hybrid pixel detector with 75 μm pixel pitch. It was designed to cope with high X-ray intensities and therefore it is a very good candiate for synchrotron applications. In order to use this detector in an application, a dedicated setup must be designed and built allowing proper operation of the detector within the experiment. The paper presents two setups built for the purpose of Pump-Probe-Probe experiments at the Synchrotron SOLEIL and XPCS experiments at the APS.