Future weather scenarios significantly affect indoor thermal comfort, influencing people’s well-being and productivity at work. Thus, future weather scenarios should be considered in the design phase to improve a building’s climate change resilience for new constructions as well as renovations in building stock. As thermal comfort is highly influenced by internal and external thermal loads resulting from weather conditions and building usage, only a dynamic building performance simulation (BPS) can predict the boundary conditions for a thermal comfort analysis during the design stage. As the model setup for a BPS requires detailed information about building geometry, materials, and usage, recent research activities have tried to derive the required simulation models from the open BIM (Building Information Modeling) Standard IFC (Industry Foundation Classes). However, even if IFC data are available, they are often faulty or incomplete. We propose a template-based enrichment of the BPS models that assists with imputing missing data based on archetypal usage of thermal zones. These templates are available for standardized enrichment of BPS models but do not include the required parameters for thermal comfort analysis. This study presents an approach for IFC-based thermal comfort analysis and a set of zone-usage-based templates to enrich thermal comfort input parameters.
We investigated the effect of an elevated ambient temperature on performance in a persistence task. The task involved the coding of incorrect symbols and participants were free to decide how long to spend performing this task. Applying a between-subject design, we tested 125 students in an office-like environment in one of the three temperature conditions. The comfort condition (Predicted Mean Vote [PMV] = 0.01) featured an average air temperature of 24 °C. The elevated ambient temperature condition was 28 °C (PMV = 1.17). Condition three employed an airstream of approximately 0.8 m/s, intended to compensate for performance decrements at the elevated air temperature (28 °C, PMV = 0.13), according to Fanger’s thermal comfort equation. Participants in the warm condition were significantly less persistent compared with participants in the control and compensation conditions. As predicted by the thermal comfort equation, the airstream seemed to compensate for the higher temperature. Participants’ persistence in the compensation and comfort conditions did not differ. Practitioner Summary: A laboratory experiment involving a simulated office environment and three ambient temperature conditions (24 °C, 28 °C and 28 °C plus airstream) showed that persistence at a task is significantly impaired at 28 °C. An airstream of 0.8 m/s at 28 °C compensated for the disinclination to persist with the task.