Jian Yang

Dr. Jian Yang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2023 in Buildings
Verified
Journal Article
Open access
PDF file
JYJian Yang
Jian Yang
LJLiqiang Jiang
Liqiang Jiang
HGHaizhu Guo
Haizhu Guo
GYGuohuang Yao
Guohuang Yao
The application of ECC materials in major stress and energy dissipation regions of prefabricated reinforced concrete (RC) shear walls to form prefabricated ECC/RC combined shear walls can improve the seismic capacity of structures. The stress and damage mechanism of a 1/2-scale two-story spatial structure specimen of the prefabricated ECC/RC combined shear wall under low cyclic loading is numerically simulated. By comparing the numerical simulation results with the experimental results, the correctness of the numerical simulation method is verified. On this basis, a detailed whole process analysis is carried out by the numerical simulation method, including the stress distribution of the concrete and ECC, compression damage of the concrete and ECC, crack distribution of the concrete and ECC, stress distribution of the reinforcement, and structural and fabricated joint displacement. The whole process analysis effectively reflects the cracking, damage, and failure law of the specimen and extensively reveals the failure mechanism and internal force distribution law of the fabricated ECC/RC combined shear wall structure. Based on the stress and damage mechanism, the seismic energy dissipation performance with different ranges of ECC use in the bottom of the wall is studied. The results show that when the ECC height of the bottom walls is 400 mm, the energy dissipation performance of the prefabricated ECC/RC combined shear wall structure reaches an optimal value.

30 March 2024 in Buildings
Verified
Journal Article
Open access
PDF file
JYJian Yang
Jian Yang
MSMing SUN
Ming SUN
GYGuohuang Yao
Guohuang Yao
HGHaizhu Guo
Haizhu Guo
RZRumian Zhong
Rumian Zhong
This study explores an advanced prefabricated composite structure, namely ECC/RC composite shear walls with enhanced seismic performance. This performance enhancement is attributed to the strategic use of engineered cementitious composites (ECC) known for their superior ductility. The study conducts both experimental and numerical simulation analyses to scrutinize the seismic energy absorption capabilities of this innovative structure. Emphasis is placed on critical aspects, such as the optimal deployment areas for ECC within composite coupling beams and shear walls, the grade of ECC strength, the proportion of stirrups in coupling beams, and the caliber of longitudinal reinforcement. Through finite element analysis, this research quantitatively assesses the impact of these variables on seismic energy dissipation, incorporating evaluations of load–displacement hysteretic behaviors and the energy dissipation potential of ECC/RC shear wall samples. The findings suggest the optimal ECC application in the coupling beams, and within a 14% structural height at the base of shear walls. Recommended design parameters include an ECC strength grade of E40 (40 MPa), longitudinal reinforcement of HRB400 (400 MPa), and a stirrup ratio in coupling beams of 0.5%.

23 October 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
JYJian Yang
Jian Yang
MSMing SUN
Ming SUN
GYGuohuang Yao
Guohuang Yao
HGHaizhu Guo
Haizhu Guo
RZRumian Zhong
Rumian Zhong
The prefabricated ECC/RC combined shear wall structure is an innovative prefabricated composite structure with better seismic performance by using ECC materials with better ductility in the main force and energy consumption regions of the prefabricated reinforced concrete (RC) shear wall structure. The key factors controlling the seismic energy dissipation capacity of this kind of structure are the use regions of ECC in composite coupling beams, use regions of ECC in shear walls, strength of ECC, stirrup ratio of coupling beams, strength of longitudinal reinforcement and so on. The parameters affecting seismic energy consumption are quantified by the finite element analysis method. By comparing and analyzing the load-displacement curves, hysteresis curves, energy dissipation capacity and stiffness degradation of the prefabricated ECC/RC combined shear wall structure specimen under these parameters, it is proposed that the best use regions of ECC is the cast-in-situ zone of the coupling beams with the scope of no more than400 mm at the shear walls’ bottom. The strength grade, the strength grade of longitudinal reinforcement, and the stirrup ratio of coupling beams are suggested design as E40, HRB400 and 0.5%, respectively.