Over the years, monitoring the quality of the environment, food, and human health has emerged as a fundamental objective of scientific investigation. Various analytical techniques have been devised and continually refined to ensure a high standard of living. Among these methods, dispersive liquid–liquid microextraction (DLLME) stands out as a widely used approach to conduct analytical evaluations and pre-concentrations of chemical compounds. This review provides an account of the evolution of DLLME over the past five years (2018–2023). The Scopus search engine was used to search for scientific articles. The selection of relevant articles was carried out according to the criteria described below. Emphasis was placed on the evolution that DLLME has undergone over the years by integrating it with other pre-concentration methods in order to amplify the concentration factor and improve analytical precision. Factors such as solvent dispersion and extraction, dispersion formation, and the recovery of the solvent containing the extracted analytes were examined. Additionally, derivatization systems were evaluated to refine both qualitative and quantitative analysis. These efforts aim to introduce methods that are safe for operators, environmentally friendly, and economical. This review evaluates the advantages and disadvantages displayed by the evolution of this technique in the phases before, during, and after its application.
Phthalates (or phthalate esters, PAEs) and bisphenol A (BPA) are widely used in various industries, particularly in the fields of cosmetics and packaging, and they increase the malleability and workability of materials. As a result of their use, some international health organizations have begun to study them. In this study, the authors developed a methodology for the simultaneous determination of dimethyl phthalate (DMP), diethyl phthalate (DEP), diisobutyl phthalate (DiBP); dibutyl phthalate (DBP), bis(2-ethylhexyl) phthalate (DEHP); di-n-octyl-phthalate (DnOP) and bisphenol A (BPA) from drinking and non-potable waters. The extraction of PAEs and BPA was performed using a solvent-based dispersive liquid–liquid microextraction (SB-DLLME) method. The analytical determination was performed using a gas chromatography–ion trap mass spectrometry (GC-IT/MS) analysis. The entire procedure was validated as recoveries were studied according to the volume and the extraction solvent used, pH, and ionic strength. Dynamic linearity ranges and linear equations of all the compounds were experimentally determined as well as the limit of detection (LOD) (1–8 ng mL−1) and the limit of quantification (LOQ) (5–14 ng mL−1), reproducibility, and sensitivity. The method was applied to 15 water samples (mineral water and tap water) for determining PAEs and BPA released from the plastic container. After the release simulation, four PAEs (i.e., DiBP, DBP, DHEP, and DnOP) were determined at very low concentrations (below 1.2 ng mL−1) in two water samples from (sport) bottles.
Formaldehyde, the simplest molecule of the aldehyde group, is a gaseous compound at room temperature and pressure, is colorless, and has a strong, pungent odor. It is soluble in water, ethanol, and diethyl ether and is used in solution or polymerized form. Its maximum daily dosage established by the EPA is 0.2 μg g−1 of body weight whereas that established by the WHO is between 1.5 and 14 mg g−1: it is in category 1A of carcinogens by IARC. From an analytical point of view, formaldehyde is traditionally analyzed by HPLC with UV-Vis detection. Nowadays, the need to analyze this compound quickly and in situ is increasing. This work proposes a critical review of methods for analyzing formaldehyde in food using sensing methods. A search carried out on the Scopus database documented more than 50 papers published in the last 5 years. The increase in interest in the recognition of the presence of formaldehyde in food has occurred in recent years, above all due to an awareness of the damage it can cause to human health. This paper focuses on some new sensors by analyzing their performance and comparing them with various no-sensing methods but focusing on the determination of formaldehyde in food products. The sensors reported are of various types, but they all share a good LOD, good accuracy, and a reduced analysis time. Some of them are also biodegradable and others have a very low cost, many are portable and easy to use, therefore usable for the recognition of food adulterations on site.
The honeybee (Apis mellifera L.) has been used in several studies for monitoring the environmental health status in terms of pollution, due to its wide-ranging foraging flights. Based on this consideration, this study aimed to analyze heavy metal pollution in Molise Region (Italy), by investigating five sites characterized by different levels of contamination. Furthermore, the authors carried out a sampling activity for a long period, in order to obtain a complete dataset. In this way, detailed information about the status of the environments was able to be obtained. The main purpose of this work was to assess the health status of Molise Region and to confirm the suitability of honeybees as environmental bioindicators of heavy metal pollution, by analyzing their variability over time and space. Furthermore, the study compared the health status associated with contamination in terms of heavy metals with that in two different areas of Italy, using hierarchical cluster analysis and principal component analysis, to evaluate the correlation existing among the three different areas of Italy. Following the findings, the authors suggest the use of honeybees as a bioindicator for heavy metal pollution in air quality studies.
Over the years, anthropogenic sources have increasingly affected food quality. One of the most sensitive and nutritional matrices affected by chemical contamination is honey, due to the use of acaricides. Recently, the attention has moved to the presence of phthalates (PAEs) and bisphenol A (BP-A), molecules present in plastic materials used both in the production phase and in the conservation of honey. In this study, an analytical method for the simultaneous determination of PAEs (dimethyl phthalate DMP, diethyl phthalate DEP, diisobutyl phthalate DiBP, dibutyl phthalate DBP, bis(2-ethylhexyl) phthalate DEHP, and di-n-octyl-phthalate DnOP) and BP-A was developed. The extraction technique is the ultrasound-vortex-assisted dispersive liquid–liquid microextraction (UVA-DLLME), using 150 µL of toluene as an extraction solvent, followed by the gas chromatography coupled with ion trap mass spectrometry analysis (GC–IT/MS). The developed method is sensitive, reliable, and reproducible: it shows high correlation coefficients (R > 0.999); limits of detection (LODs) less than 11 ng·g−1; limits of quantification (LOQs) less than 16 ng·g−1; repeatability below 3.6%, except BP-A (11.6%); and accuracy below 4.8%, except BP-A (17.6%). The method was applied to 47 nectar honey samples for evidencing similarities among them. The chemometric approach based on Hierarchical Cluster Analysis and Principal Component Analysis evidenced some similitudes about sample origin as well as marked differences between PAE and BP-A sources.
In this paper, an analytical protocol was developed for the simultaneous determination of phthalates (di-methyl phthalate DMP, di-ethyl phthalate DEP, di-isobutyl phthalate DiBP, di-n-butyl phthalate DBP, bis-(2-ethylhexyl) phthalate DEHP, di-n-octyl phthalate DNOP) and bisphenol A (BPA). The extraction technique used was the ultrasound vortex assisted dispersive liquid–liquid microextraction (UVA-DLLME). The method involves analyte extraction using 75 µL of benzene and subsequent analysis by gas chromatography combined with ion trap mass spectrometry (GC-IT/MS). The method is sensitive, reliable, and reproducible with a limit of detection (LOD) below 13 ng g−1 and limit of quantification (LOQ) below 22 ng g−1 and the intra- and inter-day errors below 7.2 and 9.3, respectively. The method developed and validated was applied to six honey samples (i.e., four single-use commercial ones and two home-made ones. Some phthalates were found in the samples at concentrations below the specific migration limits (SMLs). Furthermore, the commercial samples were subjected to two different thermal stresses (24 h and 48 h at 40 °C) for evidence of the release of plastic from the containers. An increase in the phthalate concentrations was observed, especially during the first phase of the shock, but the levels were still within the limits of the regulations.