Jun Zhu

Jun Zhu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SCShudong Chen
Shudong Chen
SZShuang Zhang
Shuang Zhang
JZJun Zhu
Jun Zhu
XLXinqun Luan
Xinqun Luan
Characteristic response parameterized in time-dependent target intrinsic polarizabilities has been widely used to create feature libraries for unexploded ordnance (UXO) discrimination. This paper discusses the accurate measurement of characteristic response for UXOs with transient electromagnetic (TEM) system. First, a specially designed TEM system, which utilizes a modified solenoid and a pair of rectangular coils as transmitting coils to ensure the uniformity of primary field up to 96% throughout the target, is described. Then, the characteristic responses of 12 UXOs are measured from directions vertical or parallel to the axis at distances from 40 cm to 120 cm. The measured characteristic responses show a power law decay function at an early time and an exponential decay function at a later time. The characteristic responses parallel to the target axis are larger and the decay is considerably slower than those vertical to the axis, leading to one to two orders of magnitude difference at a later time. Results also show that the characteristic response measured from the direction vertical to the axis of the target is more precise than that from the direction parallel to the axis at the same distance. The portion of the target that is close to the system accounts for a large proportion of the response. A target can be approximated as a single dipole only when it is located no less than twice its length from the system. Finally, the characteristic responses of 12 targets are parameterized with the Pasion–Oldenburg expression for feature library creation.

17 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
HWHaofeng Wang
Haofeng Wang
SCShudong Chen
Shudong Chen
SZShuang Zhang
Shuang Zhang
ZYZhiwen Yuan
Zhiwen Yuan
HZHaiyang Zhang
Haiyang Zhang
JZJun Zhu
Jun Zhu
Portable transient electromagnetic (TEM) systems can be well adapted to various terrains, including mountainous, woodland, and other complex terrains. They are widely used for the detection of unexploded ordnance (UXO). As the core component of the portable TEM system, the sensor is constructed with a transmitting coil and a receiving coil. Based on the primary field of the transmitting coil and internal noise of the receiving coil, the design and testing of such a sensor is described in detail. Results indicate that the primary field of the transmitting coil depends on the diameter, mass, and power of the coil. A higher mass–power product and a larger diameter causes a stronger primary field. Reducing the number of turns and increasing the clamp voltage reduces the switch-off time of the transmitting current effectively. Increasing the cross-section of the wire reduces the power consumption, but greatly increases the coil’s weight. The study of the receiving coil shows that the internal noise of the sensor is dominated by the thermal noise of the damping resistor. Reducing the bandwidth of the system and increasing the size of the coil reduces the internal noise effectively. The cross-sectional area and the distance between the sections of the coil have little effect on the internal noise. A less damped state can effectively reduce signal distortion. Finally, a portable TEM sensor with both a transmitting coil (constructed with a diameter, number of turns, and transmitting current of 0.5 m, 30, and 5 A, respectively) and a receiving coil (constructed with a length and resonant frequency of 5.6 cm and 50 kHz, respectively) was built. The agreement between experimental and calculated results confirms the theory used in the sensor design. The responses of an 82 mm mortar shell at different distances were measured and inverted by the differential evolution (DE) algorithm to verify system performance. Results show that the sensor designed in this study can not only detect the 82 mm mortar shell within 1.2 m effectively but also locate the target precisely.

10 August 2020 in IEEE Access
Verified
Journal Article
Open access
SCShudong Chen
Shudong Chen
SZShuang Zhang
Shuang Zhang
HJHejun Jiang
Hejun Jiang
JZJun Zhu
Jun Zhu
Location and characterization of a buried target from its electromagnetic induction response is a key problem for unexploded ordnance (UXO) detection. This article focuses on the influence of target size, depth, and orientation on its location and characterization on the basis of single dipole model with differential evolution (DE) algorithm against data collected by a portable transient electromagnetic (TEM) system. The sensor of the portable TEM system is composed of a single-layer transmitting coil and five three-component receiving coils. The diameter and current of transmitting coil are 0.5 m and 5 A. The length and resonant frequency of receiving coil are 5.6 cm and 180 kHz. The results of test-stand experiment show that the errors in location and characterization an underground target depend not only on the signal-to-noise ratio of the response, but also on the orientation of the target. For large target vertically (tail down) oriented, the estimated depth and characteristic response only represent the part of target close to the sensor, which are smaller than the real ones. For target flat-lying oriented, the algorithm overestimates both the depth and the characteristic response for the nonuniform primary field throughout the target. Finally, field experiment has been conducted. In general, the target can be located and characterized well even if the response of two targets is superimposed. The errors in estimated positions of about 5-7 cm support the conclusions from our test-stand experiment. These errors are especially critical when excavating targets.

2 March 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JGJian Ge
Jian Ge
RWRui Wang
Rui Wang
HDHaobin Dong
Haobin Dong
Huan LiuHuan Liu
Huan Liu
QZQianwei Zheng
Qianwei Zheng
HZHaiyang Zhang
Haiyang Zhang
The diversity of magnetic field information obtained in marine geomagnetic measurements is of great relevance to defining detailed features of the targets. In this article, a solution algorithm based on the combination of scalar and vector fields is proposed. The magnetic direction of the geomagnetic field was obtained by repeatedly applying bias fields, and the multiparameter integrated measurement is realized based on the geometric relationship of the geomagnetic parameters. To make an instrument feasible for undersea measurement, a miniaturized multiparameter magnetometer was constructed within the limited space of a pressure tank, using an Overhauser scalar sensor and a spherical coil for generating bias fields. Test platforms were built to evaluate the scalar sensor and spherical coil. Results from a nonmagnetic laboratory showed that the expanded uncertainty of the scalar sensor was 0.11 nT, whereas the magnetic field generated by the spherical coil had 97% uniformity and completely engulfed the scalar sensor. Moreover, field experiments indicated that the standard deviation of prototype instrument in magnetic direction (3 $^{\prime \prime }$ ) was close to that of declination–inclination magnetometer, whereas its standard deviation in Z -component of 0.24 nT was better than that of a commercial fluxgate magnetometer. It also had markedly better measurement stability, with no temperature drift.

1 October 2019 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
SCS. Chen
S. Chen
HJH. Jiang
H. Jiang
JZJun Zhu
Jun Zhu
YQY. Qiu
Y. Qiu
SZS. Zhang
S. Zhang

17 January 2017 in Sensors
Verified
Journal Article
Open access
PDF file
SCShudong Chen
Shudong Chen
Shuxu GuoShuxu Guo
Shuxu Guo
HWHaofeng Wang
Haofeng Wang
MHMiao He
Miao He
XLXiaoyan Liu
Xiaoyan Liu
JZJun Zhu
Jun Zhu
The investigation depth of transient electromagnetic sensors can be effectively increased by reducing the system noise, which is mainly composed of sensor internal noise, electromagnetic interference (EMI), and environmental noise, etc. A high-sensitivity airborne transient electromagnetic (AEM) sensor with low sensor internal noise and good shielding effectiveness is of great importance for deep penetration. In this article, the design and optimization of such an AEM sensor is described in detail. To reduce sensor internal noise, a noise model with both a damping resistor and a preamplifier is established and analyzed. The results indicate that a sensor with a large diameter, low resonant frequency, and low sampling rate will have lower sensor internal noise. To improve the electromagnetic compatibility of the sensor, an electromagnetic shielding model for a central-tapped coil is established and discussed in detail. Previous studies have shown that unclosed shields with multiple layers and center grounding can effectively suppress EMI and eddy currents. According to these studies, an improved differential AEM sensor is constructed with a diameter, resultant effective area, resonant frequency, and normalized equivalent input noise of 1.1 m, 114 m2, 35.6 kHz, and 13.3 nV/m2, respectively. The accuracy of the noise model and the shielding effectiveness of the sensor have been verified experimentally. The results show a good agreement between calculated and measured results for the sensor internal noise. Additionally, over 20 dB shielding effectiveness is achieved in a complex electromagnetic environment. All of these results show a great improvement in sensor internal noise and shielding effectiveness.