In this research, the feasibility of strengthening and repairing two‐way reinforced concrete slabs and the effect of compressive strength on the properties of strengthened and repaired slabs using CFRP sheets were studied. The experimental program includes testing twelve samples. Four samples served as control panels, while four samples were strengthened using CFRP sheets to study the effect of carbon sheets on the ultimate load capacity. Also, the four pretested control panels were also taken and rerepaired using CFRP sheets and retested for the purpose of evaluating their properties after repair. The ultimate load capacity, energy dissipation capacity, initial stiffness, and failure pattern were explained by the experimental results obtained. The experimental results revealed that the use of CFRP strips led to an improvement in the average ultimate loading capacity by 16.2% and 6.45% for the strengthening and repairing system, respectively. Also, the utilization of the CFRP strips as a strengthening system significantly improved the stiffness and the cracking load of RC two‐way slabs. It was also noted that the ultimate loading capacity was proportionally related to the concrete strength for strengthened slabs with an increase of 23.3% for slabs with the highest concrete strength (C: 70).
The bond strength of tension lap splices in recycled-coarse-aggregate-reinforced concrete strengthened with hybrid (steel–polyolefin) fibers was experimentally investigated. This study was conducted with the help of twelve lap-spliced beam specimens. The replacement level of coarse natural aggregates with recycled concrete aggregate (RCA) was 100%. The following variables were investigated: various ranges of steel–polyolefin fibers—100–0%, 75–25%, 50–50%, 25–75%, and 0–100%—in which the total volume fraction of fibers () remains constant at 1%; and two lengths of lap splices for rebars of 16 mm diameter (): 10 and 15 . The test results showed that the best range of steel–polyolefin fibers that gave the highest bond strength was 50–50%. The ductility of the fiber-reinforced recycled-aggregate (FR-RA) concrete was significantly improved for all the cases of various relative ratios of steel and polyolefin fibers. The bond strength was also predicted using three empirical equations proposed by Orangun et al., Darwin et al., and Harajli. This study showed that the Harajli equation gave a more accurate estimation of the bond strength of reinforcing bars embedded in FR-RA concrete than those proposed by Orangun et al. and Darwin et al.
30 June 2025 in Mathematical Modelling of Engineering Problems
This study investigates the structural performance of semi-precast concrete slabs (SPCSs), an innovative hybrid construction system that integrates factory-produced precast concrete units with a cast-in-place (CIP) concrete topping to create a composite structural element. This system offers notable advantages in terms of construction acceleration, improved quality control, and reduced labor requirements, as the precast unit serves as both a load-bearing component and a permanent formwork. To evaluate the structural behavior of the SPCSs, an experimental program was conducted on seven full-scale, one-way slab specimens with varying span lengths (4.75 m and 6.0 m), precast unit thicknesses (80 mm and 100 mm), and shear connector geometries (rectangular and triangular). A control slab without shear connectors was also tested to establish a baseline for comparison. The results demonstrated that the inclusion of shear connectors significantly enhanced structural performance. Specifically, the ultimate load capacity increased by 186.4%, and the cracking load increased by 220% compared to the control specimen. Rectangular connectors proved more effective than triangular ones in minimizing interface slip and enhancing ductility. The initial stiffness increased by 163.95%, while the energy dissipation capacity improved by 411.35%. Although variations in span length and topping thickness had relatively minor effects, the presence and geometry of shear connectors played a decisive role in ensuring effective composite action. All reinforced slabs exhibited flexural failure modes, indicating strong bonding and interaction between the precast and cast-in-place (CIP) concrete layers, whereas the control slab experienced premature failure due to interlayer debonding. Theoretical equations based on ACI 318-19 were used to estimate the nominal flexural capacities of the hybrid SPCS slabs, showing reliable agreement with the experimental results. These findings demonstrated the importance of shear connector design in maximizing the load-bearing capacity, ductility, and structural stiffness of SPCS systems under both service and extreme loading conditions.