Mingyu Du

Mr. Mingyu Du


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
BFBingfei Fan
Bingfei Fan
LZLuobin Zhang
Luobin Zhang
SCShibo CAI
Shibo CAI
MDMingyu Du
Mingyu Du
Tao LiuTao Liu
Tao Liu
PSPeter Shull
Peter Shull
Wearable inertial measurement units (IMUs) have been widely used in human movement analysis outside the laboratory. However, the IMU-based orientation estimation remains challenging, particularly in scenarios involving relatively fast movements. Increased sampling rate has the potential to improve accuracy, but it also increases power consumption and computational complexity. The relationship between sampling frequencies and accuracies remains unclear. We thus investigated the specific influence of IMU sampling frequency on orientation estimation across a spectrum of movement speeds and recommended sufficient sampling rates. Seventeen healthy subjects wore IMUs on their thigh, shank, and foot and performed walking (1.2 m/s) and running (2.2 m/s) trials on a treadmill, and a motion testbed with an IMU was used to mimic high-frequency cyclic human movements up to 3.0 Hz. Four widely used IMU sensor fusion algorithms computed orientations at 10, 25, 50, 100, 200, 400, 800, and 1600 Hz and were compared with marker-based optical motion capture (OMC) orientations to determine accuracy. Results suggest that the sufficient IMU sampling rate for walking is 100 Hz, running is 200 Hz, and high-speed cyclic movements is 400 Hz. The accelerometer sampling rate is less important than the gyroscope sampling rate. Further, accelerometer sampling rates exceeding 100 Hz even resulted in decreased accuracy because excessive orientation updates using distorted accelerations and angular velocity introduced more error than merely using angular velocity. These findings could serve as a foundation to inform wearable IMU development or selection across a spectrum of human gait movement speeds.

16 August 2024 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
MDMingyu Du
Mingyu Du
BLBowen Lv
Bowen Lv
BFBingfei Fan
Bingfei Fan
XLXiaoling Li
Xiaoling Li
JYJunze Yu
Junze Yu
SCShibo CAI
Shibo CAI
Ankle moment plays an important role in human gait analysis, patients' rehabilitation process monitoring, and the human-machine interaction control of exoskeleton robots. However, current ankle moment estimation methods mainly rely on inverse dynamics (ID) based on optical motion capture system (OMC) and force plate. These methods rely on fixed instruments in the laboratory, which are difficult to be applied to the control of exoskeleton robots. To solve this problem, this paper developed a new distributed plantar pressure system and proposed an ankle plantar flexion moment estimation method using the plantar pressure system. We integrated eight pressure sensors in each insole to collect the pressure data of the key area of the foot and then used the plantar pressure data to train four neural networks to obtain the ankle moment. The performance of the models was evaluated using normalized root mean square error (NRMSE) and cross-correlation coefficient (ρ). During experiments, eight subjects were recruited for the overground walking tests, and OMC and force plate were used as the gold standard. The results indicate that the Genetic algorithm - Gated recurrent unit estimation algorithm (GA-GRU) was the best estimation model which achieved the highest accuracy in generalized ankle moment estimation (NRMSE = 7.23%, ρ = 0.85) compared with the other models. The designed novel distributed plantar pressure system and the proposed method could serve as a joint moment estimation approach in wearable robot control and human motion state monitoring.

22 April 2025 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
BFBingfei Fan
Bingfei Fan
LZLuobin Zhang
Luobin Zhang
ZWZhiheng Wang
Zhiheng Wang
MDMingyu Du
Mingyu Du
SCShibo CAI
Shibo CAI
TJTianyu Jiang
Tianyu Jiang
Assessing walking balance is crucial for identifying fall risks in older adults and optimizing rehabilitation strategies for patients with walking impairments. However, current laboratory-based methods for assessing dynamic walking balance are hard to use in daily life scenarios. To address this issue, we proposed a walking balance analysis method based on a self-developed inertial measurement unit (IMU) system consisting of 17 low-cost IMUs. This method collects motion data from key segments of the human body using the IMUs, then uses OpenSim to reconstruct human motion and extract gait parameters, and finally, analyzes walking stability through an improved compass gait model. For validation, we recruited 20 subjects to perform normal and perturbed walking experiments, and the optical motion capture system was used as the reference system. Results indicated that the root mean square error (RMSE) of the gait cycle was 0.158 seconds, and RMSEs of step length and maximum foot clearance were 0.025 m and 0.045 m, respectively. Under normal walking conditions, we calculated the balance indicator, the minimum Euclidean distance, and its RMSE was 0.027. In the perturbed walking experiment, we found that the state point significantly exceeded the balance boundary, then gradually converged and returned to the steady state, showing the effectiveness of the proposed balance stability assessment method. The developed system and the proposed method have the advantages of lightweight design, flexible application scenarios, and low power consumption, which provide a novel technical approach for daily monitoring and assessing walking balance in patients with walking impairments.

2 April 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KZKewen Zhang
Kewen Zhang
XLXiaoling Li
Xiaoling Li
XCXin Chen
Xin Chen
LYLongjie Yu
Longjie Yu
YJYinan Jin
Yinan Jin
SCShibo CAI
Shibo CAI
Accurately recognizing gait phases, by applying proper instrumentation and measurement, is significant in walking rehabilitation training for patients with impaired mobility. In this study, seven phases of complete stand-walk-stand cycle as well as continuous daily walking were recognized based on muscle synergy and PSO-CNN-LSTM model. Firstly, the complete stand-walk-stand walking cycle were divided into starting phase, terminal swing phase, loading response phase, mid-stance phase, terminal stance phase, initial swing phase, and stopping phase, based on the features of surface electromyography (sEMG) collected by portable sEMG acquisition system and measured motion data of lower limb. Secondly, a muscle weight matrix and an activation sequence matrix were calculated by using non-negative matrix factorization (NMF). Finally, a PSO-CNN-LSTM network was designed to recognize the complete stand-walk-stand cycle by applying above mentioned matrices as input. Fourteen subjects volunteered to perform linear walking experiments under procedure to verify the feasibility of the proposed approach by comparing results with other classifiers and features. Experimental results show that the proposed approach was capable of achieving an average recognition accuracy of up to 85.384%. This work will offer promising gait recognition method for rehabilitation robots to achieve natural and flexible human-robot interaction.

7 January 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LTLiangjie Tu
Liangjie Tu
KZKewen Zhang
Kewen Zhang
MDMingyu Du
Mingyu Du
GBGuanjun BAO
Guanjun BAO
Tao LiuTao Liu
Tao Liu
SCShibo CAI
Shibo CAI
The continuous prediction of the desired gait trajectory of the paretic leg is a key task for the lower limb rehabilitation robot to assist the coordinated motion of the healthy and paretic legs of stroke patients, which has important research significance. In this paper, we propose a continuous prediction method for the desired gait trajectory of the paretic leg based on the sEMG signal of the healthy leg. In this method, an ISSA-CNN-SVR cascade network prediction model is designed. Based on this model, the mapping relationship between the sEMG signal of the healthy leg and the hip and knee joint angle of the paretic leg is established. The model input is the 8-channel sEMG signal of the healthy leg in the current instantaneous moment, and the output is the desired gait trajectory (hip and knee joint angle trajectories) of the paretic leg in the instantaneous moment after 100 ms. We recruited eight healthy participants for the validation experiments. Results indicate that the proposed method can continuously and smoothly predict the hip and knee joint angle trajectories of the paretic leg for the instantaneous moment after 100 ms based on the sEMG signal of the healthy leg and the ISSA-CNN-SVR model. The average RMSE of the predicted hip and knee joint angle trajectories of the paretic leg are 4.643° and 6.845°, with average R 2 being 0.855 and 0.857, respectively, demonstrating a high level of fitting. Therefore, this study is of great significance to improve the gait coordination of the healthy and paretic legs of robot-assisted stroke patients in the process of rehabilitation training.

18 April 2026 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
JXJiayao Xiang
Jiayao Xiang
DLDandan Liu
Dandan Liu
XCXin Chen
Xin Chen
WWWei Wei
Wei Wei
MDMingyu Du
Mingyu Du
TJTianyu Jiang
Tianyu Jiang