Shibo CAI

Shibo CAI


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
XCXin Chen
Xin Chen
SCShibo CAI
Shibo CAI
LYLongjie Yu
Longjie Yu
XLXiaoling Li
Xiaoling Li
BFBingfei Fan
Bingfei Fan
GBGuanjun BAO
Guanjun BAO
Sit-to-stand transition phase identification is vital in the control of a wearable exoskeleton robot for assisting patients to stand stably. In this study, we aim to propose a method for segmenting and identifying the sit-to-stand phase using two inertial sensors. First, we defined the sit-to-stand transition into five phases, namely, the initial sitting phase, the flexion momentum phase, the momentum transfer phase, the extension phase, and the stable standing phase based on the preprocessed acceleration and angular velocity data. We then employed a threshold method to recognize the initial sitting and the stable standing phases. Finally, we designed a novel CNN-BiLSTM-Attention algorithm to identify the three transition phases, namely, the flexion momentum phase, the momentum transfer phase, and the extension phase. Fifteen subjects were recruited to perform sit-to-stand transition experiments under a specific paradigm. A combination of the acceleration and angular velocity data features for the sit-to-stand transition phase identification were validated for the model performance improvements. The integration of the CNN, Bi-LSTM, and Attention modules demonstrated the reasonableness of the proposed algorithms. The experimental results showed that the proposed CNN-BiLSTM-Attention algorithm achieved the highest average classification accuracy of 99.5% for all five phases when compared to both traditional machine learning algorithms and deep learning algorithms on our customized dataset (STS-PD). The proposed sit-to-stand phase recognition algorithm could serve as a foundation for the control of wearable exoskeletons and is important for the further development of intelligent wearable exoskeleton rehabilitation robots.

28 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YYYangqing Ye
Yangqing Ye
MXMa xiaolong
Ma xiaolong
XZXuanyi Zhou
Xuanyi Zhou
GBGuanjun BAO
Guanjun BAO
Weiwei WanWeiwei Wan
Weiwei Wan
SCShibo CAI
Shibo CAI
Home service robots operating indoors, such as inside houses and offices, require the real-time and accurate identification and location of target objects to perform service tasks efficiently. However, images captured by visual sensors while in motion states usually contain varying degrees of blurriness, presenting a significant challenge for object detection. In particular, daily life scenes contain small objects like fruits and tableware, which are often occluded, further complicating object recognition and positioning. A dynamic and real-time object detection algorithm is proposed for home service robots. This is composed of an image deblurring algorithm and an object detection algorithm. To improve the clarity of motion-blurred images, the DA-Multi-DCGAN algorithm is proposed. It comprises an embedded dynamic adjustment mechanism and a multimodal multiscale fusion structure based on robot motion and surrounding environmental information, enabling the deblurring processing of images that are captured under different motion states. Compared with DeblurGAN, DA-Multi-DCGAN had a 5.07 improvement in Peak Signal-to-Noise Ratio (PSNR) and a 0.022 improvement in Structural Similarity (SSIM). An AT-LI-YOLO method is proposed for small and occluded object detection. Based on depthwise separable convolution, this method highlights key areas and integrates salient features by embedding the attention module in the AT-Resblock to improve the sensitivity and detection precision of small objects and partially occluded objects. It also employs a lightweight network unit Lightblock to reduce the network’s parameters and computational complexity, which improves its computational efficiency. Compared with YOLOv3, the mean average precision (mAP) of AT-LI-YOLO increased by 3.19%, and the detection precision of small objects, such as apples and oranges and partially occluded objects, increased by 19.12% and 29.52%, respectively. Moreover, the model inference efficiency had a 7 ms reduction in processing time. Based on the typical home activities of older people and children, the dataset Grasp-17 was established for the training and testing of the proposed method. Using the TensorRT neural network inference engine of the developed service robot prototype, the proposed dynamic and real-time object detection algorithm required 29 ms, which meets the real-time requirement of smooth vision.

11 July 2019 in Robotica
Verified
Journal Article
Closed access
PDF file
GBGuanjun BAO
Guanjun BAO
LCLingfeng Chen
Lingfeng Chen
YZYaqi Zhang
Yaqi Zhang
SCShibo CAI
Shibo CAI
FXFang XU
Fang XU
LZLibin Zhang
Libin Zhang
SUMMARY: In recent years, soft robotics is widely considered as the most promising field for both research and application. First of all, the actuator is fundamental for designing, modeling, and controlling of soft robots. This paper presents a new type of pneumatic trunk-like soft actuator, which contains a chamber for stiffness adjustment in addition to three chambers for driving. Thus, the salient feature of the proposed actuator is the ability of stiffness self-regulation. The structure of the proposed actuator is described in detail. Then the theoretical models for elongation and bending motion of the actuator are established. The elongation as well as single-chamber and multi-chamber driving bending of the actuator were tested to verify the mathematical models. Finally, a dual-segment soft robot based on the proposed trunk-like soft actuator was developed and tested by experiments, which implies its potential application in practice.

22 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
BFBingfei Fan
Bingfei Fan
LZLuobin Zhang
Luobin Zhang
SCShibo CAI
Shibo CAI
MDMingyu Du
Mingyu Du
Tao LiuTao Liu
Tao Liu
PSPeter Shull
Peter Shull
Wearable inertial measurement units (IMUs) have been widely used in human movement analysis outside the laboratory. However, the IMU-based orientation estimation remains challenging, particularly in scenarios involving relatively fast movements. Increased sampling rate has the potential to improve accuracy, but it also increases power consumption and computational complexity. The relationship between sampling frequencies and accuracies remains unclear. We thus investigated the specific influence of IMU sampling frequency on orientation estimation across a spectrum of movement speeds and recommended sufficient sampling rates. Seventeen healthy subjects wore IMUs on their thigh, shank, and foot and performed walking (1.2 m/s) and running (2.2 m/s) trials on a treadmill, and a motion testbed with an IMU was used to mimic high-frequency cyclic human movements up to 3.0 Hz. Four widely used IMU sensor fusion algorithms computed orientations at 10, 25, 50, 100, 200, 400, 800, and 1600 Hz and were compared with marker-based optical motion capture (OMC) orientations to determine accuracy. Results suggest that the sufficient IMU sampling rate for walking is 100 Hz, running is 200 Hz, and high-speed cyclic movements is 400 Hz. The accelerometer sampling rate is less important than the gyroscope sampling rate. Further, accelerometer sampling rates exceeding 100 Hz even resulted in decreased accuracy because excessive orientation updates using distorted accelerations and angular velocity introduced more error than merely using angular velocity. These findings could serve as a foundation to inform wearable IMU development or selection across a spectrum of human gait movement speeds.

12 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
MSMin Sun
Min Sun
XLXiangdong Li
Xiangdong Li
ZZZhou Zhou
Zhou Zhou
QZQibin Zhu
Qibin Zhu
BLBing Liu
Bing Liu
SCShibo CAI
Shibo CAI
Compared to magnetorheological fluid, magnetorheological gel has better anti-settling performance and stability. Therefore, magnetorheological gel is suitable for devices that can meet operational requirements in all aspects after long-term storage, such as the anti-recoil application of weapons. To study this in-depth, the mechanism of the influence of magnetorheological gel micro-magnetic-mechanical properties on the macro-output damping mechanics of the damper, a parallel plate model of the mixed flow mode composed of Couette shear flow and Poiseuille pressure flow was established. The theoretical analysis was of the output damping of the damper. Finally, the controllability of the damper under impact load employed magnetorheological gel was preliminarily analyzed. The results indicate that the damping coefficient of the damper increases with the increase of dynamic viscosity ηB of the magnetorheological gel, piston effective cross-sectional area AP, magnetic pole L, and Bingham coefficient Bi. Magnetorheological damper has controllability under impact load and can reach a wide controllable range under the condition under small magnetic field ranging from 0 mT to 131 mT.

20 December 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SCShibo CAI
Shibo CAI
MSMingyu Shao
Mingyu Shao
MDMingyu Du
Mingyu Du
GBGuanjun BAO
Guanjun BAO
BFBingfei Fan
Bingfei Fan
Lower limb joint angles are powerful clinical indicators for mobility assessment and gait rehabilitation training. Inertial Motion Capture (IMC), which is both accurate and convenient, is becoming an ideal method to estimate joint angles. Considering the corresponding segment and sensor frame are usually misaligned, an alignment procedure is required to determine the orientation offset between the segment and sensor frame. This paper presents a binocular-camera-assisted alignment procedure to align the frames of segment and inertial sensor. This procedure uses a binocular camera to acquire lower limb segment’s initial orientations with image-based human pose algorithm and then estimates the joint angle with kinematic constraint. The alignment procedure requires only sitting posture and does not need any functional movement. Ten healthy participants were recruited for the validation experiments, which included stand-up, turn-around, and walking. The accuracy and effectiveness of our alignment procedure were validated against the Optical Motion Capture. The mean RMSEs of hip, knee, and ankle angles were 1.6°, 2.9° and 3.9°, respectively. The result demonstrates that our procedure performs well on joint angle estimation. The proposed alignment procedure did not require any complicated functional movement, but only sitting posture, which could enable more practical joint angle estimation for patient subjects in clinical applications.