Sue Wang

Dr. Sue Wang


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2019 in Energies
Verified
Journal Article
Open access
PDF file
YWYongbin Wu
Yongbin Wu
DZDonghui Zhang
Donghui Zhang
LXLiansong Xiong
Liansong Xiong
SWSue Wang
Sue Wang
ZXZhao Xu
Zhao Xu
YZYi Zhang
Yi Zhang
Inertia effect and damping capacity, which are the basic characteristics of traditional power systems, are critical to grid frequency stability. However, the inertia and damping characteristics of grid-tied photovoltaic generation systems (GPVGS), which may affect the frequency stability of the grid with high proportional GPVGS, are not yet clear. Therefore, this paper takes the GPVGS based on droop control as the research object. Focusing on the DC voltage control (DVC) timescale dynamics, the mathematical model of the GPVGS is firstly established. Secondly, the electrical torque analysis method is used to analyze the influence law of inertia, damping and synchronization characteristics from the physical mechanism perspective. The research finds that the equivalent inertia, damping and synchronization coefficient of the system are determined by the control parameters, structural parameters and steady-state operating point parameters. Changing the control parameters is the simplest and most flexible way to influence the inertia, damping and synchronization ability of the system. The system inertia is influenced by the DC voltage outer loop proportional coefficient Kp and enhanced with the increase of Kp. The damping characteristic of the system is affected by the droop coefficient Dp and weakened with the increase of Dp. The synchronization effect is only controlled by DC voltage outer loop integral coefficient Ki and enhanced with the increase of Ki. In addition, the system dynamic is also affected by the structural parameters such as line impedance X, DC bus capacitance C, and steady-state operating point parameters such as the AC or DC bus voltage level of the system and steady-state operating power (power angle). Finally, the correctness of the above analysis are verified by the simulation and experimental results.

4 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
SWSue Wang
Sue Wang
KCKaiyuan Cui
Kaiyuan Cui
PHPengfei Hao
Pengfei Hao
In weak grid, feedforward of grid voltage control is widely used to effectively suppress grid-side current distortion of inverters caused by harmonics in point of common coupling (PCC) voltage. However, due to its introduction of a positive feedback loop related to the grid impedance, it results in a significant reduction in the system phase margin. In view of this, in this paper, the output impedance of a three-phase LCL grid-connected inverter under a quasi-proportional resonant (QPR) controller is first modeled. Instead of the traditional grid voltage feedforward control strategy, a band-pass filter is added to the grid voltage feedforward channel. Secondly, a multi-objective constraint method is proposed to make improvements to the feedforward function. Then, a multi-objective constraint function is established with the constraints of base-wave current tracking performance, system stability margin, and low-frequency amplitude, and the feasibility of its function optimization design method is verified. Theoretical analysis shows that the optimized grid voltage feedforward control strategy can effectively reshape the phase characteristics of the system output impedance, which greatly broadens the adaptation range of the system to the grid impedance. Finally, the effectiveness of the proposed control strategy is verified by building a semi-physical simulation experimental platform based on RT-LAB OP4510.

26 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
SWSue Wang
Sue Wang
XYXie yuxin
Xie yuxin
The output active power of a grid-connected inverter controlled by a traditional virtual synchronous generator (VSG) has the problems of oscillation and steady-state errors. A VSG control strategy based on improved damping and angular frequency deviation feedforward is proposed. This strategy reduces the steady-state error of active power by adding a transient damping link to a traditional VSG damping feedback channel. At the same time, the angular frequency deviation feedforward compensation is used to improve the response speed of the VSG to the active power instruction and reduce the active power overshoot in the dynamic process. First, the VSG active power closed-loop small-signal model is established. The effects of inertia and damping on the dynamic and steady-state performance of the VSG are analyzed by the root locus method. The effect of the proposed control strategy on the system is analyzed by using a closed-loop zero-pole diagram. This strategy improves the precision of active power control the dynamic performance of the system effectively. Finally, the effectiveness and superiority of the proposed control strategy are verified by Matlab/Simulink simulation and semi-physical simulation platform RT-LAB.

14 December 2023 in Electronics
Verified
Journal Article
Open access
PDF file
SWSue Wang
Sue Wang
ZYZhou Guang yuan
Zhou Guang yuan
PHPengfei Hao
Pengfei Hao
JCJingwen Chen
Jingwen Chen
Novel energy generation technologies, such as high-permeability wind power and photovoltaic systems, exhibit inherent intermittency, randomness, and volatility. During periods of energy production from these sources, the impedance of the electrical grid frequently experiences significant fluctuations. Consequently, the grid manifests characteristics akin to a weak grid, highlighting the challenges associated with integrating renewable energy sources with variable output profiles. These fluctuations lead to a shift in resonance spikes of the LCL-type filter towards the lower frequency band, consequently impacting the stability of inverter grid connections. To mitigate this issue, the present study introduces a novel approach integrating the D-split method and a proportional–differential feedforward strategy. This combination aims to reshape the inverter’s output impedance, ensuring its consistent stability even amidst significant fluctuations in grid impedance. In this research, the optimal controller parameters for systems operating under robust grid conditions are initially determined. This selection process involves the application of the D-split method, supported by graphical visualization. Additionally, the amplitude and phase angle margin tester is employed while considering the system bandwidth as a limiting constraint. Moreover, accounting for the influence of grid impedance, the D-split method is reapplied to ascertain the most suitable values for the proportional–differential feedforward parameters. This adjustment aims to enhance the adaptability of the grid-connected inverter specifically in scenarios characterized by a weak grid. The hardware-in-the-loop (HIL) simulation results demonstrate that despite the presence of harmonics within the grid and a short circuit impedance ratio (SCR) of 3, the inverter maintains grid stability and effectively suppresses harmonics. Moreover, the total harmonic distortion factor (THD) of the grid-connected current remains below 5%.

31 May 2024 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
SWSue Wang
Sue Wang
YLYufan Liu
Yufan Liu
SZShuai Zhang
Shuai Zhang
PHPengfei Hao
Pengfei Hao
JLJun Liu
Jun Liu

12 October 2026 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
SWSue Wang
Sue Wang
THTianyuan Hu
Tianyuan Hu
ZWZiting Wang
Ziting Wang
PHPengfei Hao
Pengfei Hao