Purpose: To describe the technical aspects and early results of the Candy-Plug technique for endovascular false lumen occlusion in chronic aortic dissection. Methods: A retrospective single-center study analyzing 18 consecutive patients (mean age 63 years, range 44–76; 16 men) with thoracic false lumen aneurysm in chronic aortic dissection. All patients underwent thoracic endovascular aortic repair with false lumen occlusion using the Candy-Plug technique. Primary endpoints consisted of technical success (successful deployment) and clinical success (no false lumen backflow). Secondary endpoints included 30-day mortality and morbidity as well as aortic remodeling during follow-up. Results: Technical success was 100%. Additional intraprocedural false lumen embolization at the Candy-Plug level was needed in 1 patient due to persisting false lumen backflow on the final angiogram (clinical success 94%). There were no intraprocedural complications. In the perioperative period, there were 3 minor complications: transient mild spinal cord ischemia, cervical hematoma after carotid-subclavian bypass, and a common femoral artery pseudoaneurysm. No deaths or reinterventions occurred. Complete distal false lumen occlusion was present on postoperative computed tomography in 15 patients, while 3 had minor contrast enhancement in the distal false lumen. Over a mean 9-month follow-up (range 0–26), 1 patient died due to rupture. Follow-up >6 months was available in 10 patients (mean 14.7 months, range 7–26): 7 patients showed aortic remodeling, while aneurysm size was stable in 3 patients. Conclusion: The Candy-Plug technique is a feasible endovascular method to achieve false lumen occlusion and aortic remodeling in chronic aortic dissection. It is associated with low morbidity and mortality due to its minimal invasiveness.
Purpose: To describe how to use a steerable sheath from a femoral access to catheterize antegrade branches in a branched aortic stent-graft. Technique: Following femoral cutdown, a stent-graft with antegrade branches destined for renovisceral target vessels was deployed in the desired position. A steerable sheath with a tip that rotates up to 180° was introduced from the common femoral artery and navigated to the antegrade branches for consecutive catheterization of the target vessels and deployment of one or more bridging stents per branch. The technique is demonstrated in 4 patients who underwent successful complex abdominal and thoracoabdominal branched endovascular repairs with 1, 2, and 4 antegrade branches. Conclusion: Retrograde access for complex aortic endografts with antegrade branches using a steerable sheath appears feasible and effective and may serve as an alternative to upper extremity access.
3 September 2019 in Journal of Endovascular Therapy
Purpose: To present the early results of false lumen (FL) occlusion in chronic aortic dissection using the Candy-Plug generation II (CP II), which has a self-closing fabric channel that obviates the need for separate occlusion of its center. Materials and Methods: Fourteen consecutive patients (mean age 60±11 years; 10 men) with persistent FL backflow and aneurysm formation at the thoracic segment in chronic aortic dissection underwent thoracic endovascular aortic repair (TEVAR) with FL occlusion using the refined CP II. Primary endpoints were technical success (successful deployment) and clinical success (no FL backflow at the CP II level). Secondary endpoints included 30-day mortality and morbidity and aortic remodeling during follow-up. Results: Technical success was 100%. One patient required additional intraprocedural FL embolization at the CP II level due to persistent FL backflow on final angiography (clinical success 93%), though there was no flow through the CP II center. There were no intraprocedural complications. Immediate complete FL occlusion was achieved in 12 patients; the other 2 required reintervention. One had contrast enhancement in the distal FL proximal to the CP II and was treated with coil embolization. The other patient had persistent type I endoleak at the level of the left subclavian artery (LSA) and underwent left carotid–LSA bypass and proximal stent-graft extension. One patient died due to retrograde type A aortic dissection that was not related to CP II placement. Over a mean 8-month follow-up (range 3–12), 9 patients had computed tomography angiography; 8 patients had evidence of aortic remodeling, while 1 aneurysm sac was stable. Conclusion: The CP II reduces the number of procedural steps and offers good seal, with minimal morbidity and mortality and a high rate of aortic remodeling.
Purpose: To investigate the amount of gas released from Zenith thoracic stent-grafts using standard saline flushing vs the carbon dioxide flushing technique. Methods: In an experimental bench setting, 20 thoracic stent-grafts were separated into 2 groups of 10 endografts. One group of grafts was flushed with 60 mL saline and the other group was flushed with carbon dioxide for 5 minutes followed by 60 mL saline. All grafts were deployed into a water-filled container with a curved plastic pipe; the deployment was recorded and released gas was measured using a calibrated setup. Results: Gas was released from all grafts in both study groups during endograft deployment. The average amount of released gas per graft was significantly lower in the study group with carbon dioxide flushing (0.79 vs 0.51 mL, p=0.005). Conclusion: Thoracic endografts release significant amounts of air during deployment if flushed according to the instructions for use. Application of carbon dioxide for the flushing of thoracic stent-grafts prior to standard saline flush significantly reduces the amount of gas released during deployment. The additional use of carbon dioxide should be considered as a standard flush technique for aortic stent-grafts, especially in those implanted in proximal aortic segments, to reduce the risk of air embolism and stroke.
Purpose: To describe a technique to catheterize antegrade branches of a branched thoracoabdominal endograft from a femoral access with the help of standard sheaths and a vascular suture. Technique: The technique is demonstrated in a patient who underwent successful complex thoracoabdominal branched endovascular aortic repair. After the deployment of an aortic endograft with two antegrade branches for the targeted renovisceral vessels, a standard braided sheath was preloaded with a 3/0 polypropylene suture and introduced inside an additional sheath from the groin to the thoracic aorta. Simultaneous gentle traction on the suture as the preloaded sheath was advanced achieved a very stable 180° curve of the proximal end of the sheath. It was possible to selectively catheterize the antegrade branches and respective target vessels sequentially, as well as deploy the planned bridging stents for each branch. Conclusion: The through-and-through suture technique is a helpful tool in branched endovascular aortic repair. It saves time, radiation, and materials; no snare is needed, and it can be preloaded into a sheath.