Tilo Kölbel

Prof. Tilo Kölbel

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2013 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PDF file
TKTilo Kölbel
Tilo Kölbel
CLChristina Lohrenz
Christina Lohrenz
AKArne Kieback
Arne Kieback
HDHolger Diener
Holger Diener
EDEike Sebastian Debus
Eike Sebastian Debus
ALAxel Larena-Avellaneda
Axel Larena-Avellaneda
Purpose To report a technique to create an extra-large vascular plug for occlusion of a large distal false lumen in chronic aortic dissection. Technique The “candy-plug” technique is demonstrated in a 58-year-old multimorbid man with a history of complicated acute type B aortic dissection and a 9-cm chronic thoracic false lumen aneurysm. The patient underwent a staged repair with a cervical debranching procedure as a first step and a thoracic endovascular aortic repair from the innominate artery to the celiac artery as a second step. To occlude the large false lumen from a distal route, a stent-graft was modified on-table with a diameter-restricting suture, giving it a wrapped candy–like shape. This plug was deployed into the false lumen, and the remaining opening was occluded with a standard vascular plug. On 3-month follow-up imaging, the thoracic false lumen aneurysm remained completely thrombosed. Conclusion The candy-plug technique can facilitate complete occlusion of chronic thoracic false lumen aneurysm by prohibiting distal false lumen backflow.

1 February 2014 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
TKTilo Kölbel
Tilo Kölbel
SCSebastian W. Carpenter
Sebastian W. Carpenter
CLChristina Lohrenz
Christina Lohrenz
NTNikolaos Tsilimparis
Nikolaos Tsilimparis
ALAxel Larena-Avellaneda
Axel Larena-Avellaneda
EDEike Sebastian Debus
Eike Sebastian Debus
To describe an innovative technique to occlude distal backflow into a false lumen aneurysm by controlled rupture of the dissection membrane after stent-graft implantation. The "Knickerbocker technique" involves relining the true lumen in the descending aorta with an oversized thoracic tubular endograft, followed by controlled rupture of the dissection membrane using a large compliant balloon within the graft's midsection. This maneuver, which allows expansion of the stent-graft's midsection into the false lumen, was developed in order to occlude the large false lumen distally and thus prevent continued false lumen perfusion through distal abdominal entry tears. The technique has been successfully used in 3 patients with ruptured or symptomatic chronic false lumen aneurysm in type B aortic dissection. There was no short-term mortality associated with the procedure. After a mean follow-up of 8 months, the false lumen aneurysm remained thrombosed, with no mortality after a mean clinical follow-up of 22 months. The Knickerbocker technique appears to be feasible and effective in inducing false lumen thrombosis in selected patients who undergo stent-grafting for chronic type B aortic dissection.

1 August 2009 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
TKTilo Kölbel
Tilo Kölbel
MLMats Lindh
Mats Lindh
MÅMichael Åkesson
Michael Åkesson
JWJohan Wassélius
Johan Wassélius
AGAnders Gottsater
Anders Gottsater
KIKrassi Ivancev
Krassi Ivancev
To evaluate patency and clinical outcome in patients treated with endovascular recanalization and stent placement for chronic iliac vein occlusions. During a 14-year period (1994-2008), 59 (38 women; median age 39 years) of 62 patients with chronic occlusion of the iliac vein segment in 66 limbs were successfully treated with endovascular recanalization and stent placement. A prospectively maintained database was analyzed retrospectively to obtain information on clinical details, endovascular techniques, and outcome. Three (5%) procedures failed for technical reasons. Three (5%) complications occurred, 2 (3%) of which were perforations requiring transfusion and procedure termination. Initial clinical success after 6 months was achieved in 49 (83%) of the 59 patients successfully treated initially. Primary patency after a median imaging follow-up of 25 months was 67% (44/66), assisted primary patency was 75% (49/66), and secondary patency was 79% (52/66). Fifteen (23%) of 66 limbs were asymptomatic after a median clinical follow-up of 32 months, 34 (52%) limbs were improved, 13 (20%) were unchanged, and 4 (6%) were worse compared to before intervention. Actuarial primary, assisted primary, and secondary patency rates using Kaplan-Meier survival analysis were 70%, 73%, and 80%, respectively, at 5 years. Endovascular recanalization and stent placement is a safe and effective treatment for occluded iliac veins and adjacent segments. Clinical midterm results are encouraging. Recanalized and stented segments remain patent in the majority of patients after 2 years. Endovascular treatment can ease symptoms and prevent further deterioration of patients with post-thrombotic syndrome.

22 October 2024 in Circulation
Verified
Journal Article
Closed access
Nikolaos TsilimparisNikolaos Tsilimparis
Nikolaos Tsilimparis
RMRyan Gouveia e Melo
Ryan Gouveia e Melo
ETEmanuel R. Tenorio
Emanuel R. Tenorio
SSSalvatore Scali
Salvatore Scali
BMBernardo Mendes
Bernardo Mendes
GOGustavo S Oderich
Gustavo S Oderich
BACKGROUND: Physician modified endografts (PMEGs) have been widely used in the treatment of complex abdominal aortic aneurysm and thoracoabdominal aortic aneurysm, however, previous data are limited to small single center studies and robust data on safety and effectiveness of PMEGs are lacking. We aimed to perform an international multicenter study analyzing the outcomes of PMEGs in complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. METHODS: An international multicenter single-arm cohort study was performed analyzing the outcomes of PMEGs in the treatment of elective, symptomatic, and ruptured complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. Variables and outcomes were defined according to the Society for Vascular Surgery reporting standards. Device modification and procedure details were collected and analyzed. Efficacy outcomes included technical success and safety outcomes included major adverse events and 30-day mortality. Follow-up outcomes included reinterventions, endoleaks, target vessel patency rates and overall and aortic-related mortality. Multivariable analysis was performed aiming at identifying predictors of technical success, 30-day mortality, and major adverse events. RESULTS: Overall, 1274 patients were included in the study from 19 centers. Median age was 74 (IQR, 68–79), and 75.7% were men; 45.7% were complex abdominal aortic aneurysms, and 54.3% were thoracoabdominal aortic aneurysms; 65.5% patients presented electively, 24.6% were symptomatic, and 9.9% were ruptured. Most patients (83.1%) were submitted to a fenestrated repair, 3.6% to branched repair, and 13.4% to a combined fenestrated and branched repair. Most patients (85.8%) had ≥3 target vessels included. The overall technical success was 94% (94% in elective, 93.4% in symptomatic, and 95.1% in ruptured cases). Thirty-day mortality was 5.8% (4.1% in elective, 7.6% in symptomatic, and 12.7% in ruptured aneurysms). Major adverse events occurred in 25.2% of cases (23.1% in elective, 27.8% in symptomatic, and 30.3% in ruptured aneurysms). Median follow-up was 21 months (5.6–50.6). Freedom from reintervention was 73.8%, 61.8%, and 51.4% at 1, 3, and 5 years; primary target vessel patency was 96.9%, 93.6%, and 90.3%. Overall survival and freedom from aortic-related mortality was 82.4%/92.9%, 69.9%/91.6%, and 55.0%/89.1% at 1, 3, and 5 years. CONCLUSIONS: PMEGs were a safe and effective treatment option for elective, symptomatic, and ruptured complex aortic aneurysms. Long-term data and future prospective studies are needed for more robust and detailed analysis.

19 February 2016 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
TKTilo Kölbel
Tilo Kölbel
FRFiona Rohlffs
Fiona Rohlffs
SWSabine Wipper
Sabine Wipper
SCSebastian W. Carpenter
Sebastian W. Carpenter
EDEike Sebastian Debus
Eike Sebastian Debus
NTNikolaos Tsilimparis
Nikolaos Tsilimparis
Purpose: To describe the technique of carbon dioxide (CO2) flushing of thoracic stent-grafts to reduce the risk of cerebral air embolism. Technique: To remove room air, thoracic stent-grafts were preoperatively flushed 2 minutes with carbon dioxide from a cylinder connected to the flushing chamber of the captor valves of Zenith custom-made endografts; this was followed by the standard saline flush. Thirty-six patients undergoing thoracic endovascular aortic repairs (TEVAR) involving the ascending aorta and the aortic arch received CO2-flushed Zenith endografts. One patient with a highly calcified arch experienced a minor stroke. Conclusion: Arterial air embolism is a potentially underappreciated problem of aortic endografting, especially in the proximal segments of the aorta. CO2 flushing may have the potential to reduce air embolization during TEVAR.

5 August 2018 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
VMVladimir Makaloski
Vladimir Makaloski
NTNikolaos Tsilimparis
Nikolaos Tsilimparis
FRFiona Rohlffs
Fiona Rohlffs
KSKonstantinos Spanos
Konstantinos Spanos
EDE. Sebastian Debus
E. Sebastian Debus
TKTilo Kölbel
Tilo Kölbel
Purpose: To describe how to use a steerable sheath from a femoral access to catheterize antegrade branches in a branched aortic stent-graft. Technique: Following femoral cutdown, a stent-graft with antegrade branches destined for renovisceral target vessels was deployed in the desired position. A steerable sheath with a tip that rotates up to 180° was introduced from the common femoral artery and navigated to the antegrade branches for consecutive catheterization of the target vessels and deployment of one or more bridging stents per branch. The technique is demonstrated in 4 patients who underwent successful complex abdominal and thoracoabdominal branched endovascular repairs with 1, 2, and 4 antegrade branches. Conclusion: Retrograde access for complex aortic endografts with antegrade branches using a steerable sheath appears feasible and effective and may serve as an alternative to upper extremity access.