Konstantinos Spanos

Dr. Konstantinos Spanos

Department of Vascular Surgery, University of Thessaly, Larissa, Greece
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
KSKonstantinos Spanos
Konstantinos Spanos
TKTilo Kölbel
Tilo Kölbel
JKJens C. Kubitz
Jens C. Kubitz
SWSabine Wipper
Sabine Wipper
NKNikolaos Konstantinou
Nikolaos Konstantinou
NTNikolaos Tsilimparis
Nikolaos Tsilimparis

5 August 2018 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
VMVladimir Makaloski
Vladimir Makaloski
NTNikolaos Tsilimparis
Nikolaos Tsilimparis
FRFiona Rohlffs
Fiona Rohlffs
KSKonstantinos Spanos
Konstantinos Spanos
EDE. Sebastian Debus
E. Sebastian Debus
TKTilo Kölbel
Tilo Kölbel
Purpose: To describe how to use a steerable sheath from a femoral access to catheterize antegrade branches in a branched aortic stent-graft. Technique: Following femoral cutdown, a stent-graft with antegrade branches destined for renovisceral target vessels was deployed in the desired position. A steerable sheath with a tip that rotates up to 180° was introduced from the common femoral artery and navigated to the antegrade branches for consecutive catheterization of the target vessels and deployment of one or more bridging stents per branch. The technique is demonstrated in 4 patients who underwent successful complex abdominal and thoracoabdominal branched endovascular repairs with 1, 2, and 4 antegrade branches. Conclusion: Retrograde access for complex aortic endografts with antegrade branches using a steerable sheath appears feasible and effective and may serve as an alternative to upper extremity access.

13 December 2017 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
KSKonstantinos Spanos
Konstantinos Spanos
TKTilo Kölbel
Tilo Kölbel
MTMyrto Theodorakopoulou
Myrto Theodorakopoulou
FHFranziska Heidemann
Franziska Heidemann
FRFiona Rohlffs
Fiona Rohlffs
NTNikolaos Tsilimparis
Nikolaos Tsilimparis
Purpose: To assess the short-term outcomes of the multibranched off-the-shelf t-Branch stent-graft for urgent thoracoabdominal aortic aneurysm (TAAA) repair and to evaluate the impact on outcomes of the learning curve and adherence to the instruction for use (IFU). Methods: Between 2014 and 2017, 42 patients (mean age 73.3±7 years; 26 men) underwent urgent TAAA treatment using the t-Branch stent-graft [18 in the early (2014–2015) period and 24 in the late (2016–2017) period]. Nearly half the patients were symptomatic (n=18) and 12 had contained rupture. Aneurysm diameter >80 mm was present in 12 (mean diameter 77.7±13.2 mm). Nineteen patients did not meet the IFU for the t-Branch due to target vessel anatomy. The primary endpoints were spinal cord ischemia (SCI), renal function impairment, and 30-day mortality. Target vessel patency and endoleak incidence were assessed at 30 days. Multivariate analyses examined associations between perioperative variables and outcomes; the results are presented as the odds ratio (OR) and 95% confidence interval (CI). Results: The technical success rate was 93% (39/42). Successful catheterization was achieved in 150/155 target vessels (97%). The postoperative SCI rate was 21% (5 paraplegia/4 transient paraparesis) and was correlated with age (OR 1.26, 95% CI 1.01 to 1.56, p=0.04). The renal function impairment rate was 23% (10/42; 2 temporary, 2 permanent dialysis) and was correlated with early experience (OR 7.74, 95% CI 1.3 to 43.9, p=0.019). The 30-day mortality was 14% (no intraoperative deaths); no factor was associated with mortality. During the first month, the incidences of type I, II, and III endoleaks were 0%, 43%, and 0%, respectively; branch patency was 99% (150/151). Procedure time decreased in the later experience (479±333 vs 407±25 minutes, p=0.09), though it was increased in cases outside the IFU (497±135 vs 389±118 minutes, p=0.009), along with fluoroscopy time (121±48 vs 92±33 minutes, p=0.036). Conclusion: Endovascular repair of urgent TAAA using the t-Branch is a feasible treatment option with acceptable 30-day mortality and morbidity in terms of SCI and renal function impairment. Adherence to the IFU prolonged procedure time but had no effect on outcomes. Increased experience of such cases over time may improve outcomes.

1 December 2021 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
TKTilo Kölbel
Tilo Kölbel
KSKonstantinos Spanos
Konstantinos Spanos
KJKatarzyna Jama
Katarzyna Jama
Christian Alexander BehrendtChristian Alexander Behrendt
Christian Alexander Behrendt
GPGiuseppe Panuccio
Giuseppe Panuccio
TJTomasz Jakimowicz
Tomasz Jakimowicz

1 December 2018 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
KSKonstantinos Spanos
Konstantinos Spanos
ITIoannis Tzorbatzoglou
Ioannis Tzorbatzoglou
PLParaskevi Lazari
Paraskevi Lazari
DMDimitrios Maras
Dimitrios Maras
AGAthanasios D. Giannoukas
Athanasios D. Giannoukas

1 April 2019 in Annals of Vascular Surgery
Verified
Journal Article
Closed access
KSKonstantinos Spanos
Konstantinos Spanos
TKTilo Kölbel
Tilo Kölbel
FRFiona Rohlffs
Fiona Rohlffs
FHFranziska Heidemann
Franziska Heidemann
AGAthanasios D. Giannoukas
Athanasios D. Giannoukas
NTNikolaos Tsilimparis
Nikolaos Tsilimparis