Kuan Ren

Prof. Kuan Ren


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2026 in Materials
Verified
Journal Article
Open access
PDF file
MGMeng Gu
Meng Gu
YPYaqi Peng
Yaqi Peng
XYXue Yang
Xue Yang
DZDeyu Zhao
Deyu Zhao
YHYanshuo Han
Yanshuo Han
Qianli LiQianli Li
Qianli Li
Radiation detection technology is critical in medical diagnosis, high-energy physics experiments, nuclear environmental monitoring, and radiation safety protection. Its technological iteration stems from innovations in high-performance radiation detection materials. Traditional materials often have narrow dose–response intervals, insufficient high-precision measurement capability, low spatial resolution, and poor stability, failing to meet high-precision detection requirements. Ag-doped phosphate glass (Ag-PG), based on radio-photoluminescence (RPL), effectively addresses these limitations with its comprehensive advantages: high radiation sensitivity, a wide linear dose–response range, submicron spatial resolution for radiation imaging, write-erase-rewrite capability, and visualized dose monitoring potential, and it also boasts significant fundamental research value and engineering application prospects. Specifically, while existing RPL reviews mainly provide a comprehensive analysis from the perspective of RPL and present typical RPL material systems, this paper systematically analyzes the structural characteristics of the Ag-PG matrix and the coordination configuration and site occupation of Ag ions. It clarifies RPL luminescence properties, dose–response mechanisms, and the evolution of luminescence centers, while reviewing advancements in applications such as radiation dose detection and high-resolution X-ray imaging. By summarizing the current research status, technical advantages and existing challenges of Ag-PG, this study provides theoretical references and conceptual insights to promote breakthroughs in its fundamental research and practical applications in high-precision radiation dose detection, advanced medical imaging, micro-nano-scale radiation detection, and nuclear industry non-destructive testing.

20 June 2025 in Photonics
Verified
Journal Article
Open access
PDF file
MLMingtao Li
Mingtao Li
JSJiapeng Shi
Jiapeng Shi
MWMingxun Wang
Mingxun Wang
JXJie Xu
Jie Xu
XWXin Wang
Xin Wang
DYDong Yang
Dong Yang
High-energy X-ray diagnostic systems are crucial for understanding hotspot high-density area asymmetry, fuel mixing, and other phenomena in inertial confinement fusion. To meet the demand for hotspot electron temperature measurements, we developed a high-energy dual-channel Kirkpatrick–Baez microscope. This microscope is characterized by a dual high-energy response and high spatial resolution, enabling the observation of fine structures in high-density regions of a hotspot. Spectral drift was effectively mitigated by optimizing the grazing incidence angle, and the spatial and spectral domains were coupled through experimental alignment. Herein, we describe the optical design of the proposed microscope. Furthermore, we performed simulations and backlight imaging to validate the performance of the proposed system. The results show that the spatial resolution was better than 3 μm in the center and better than 6.5 μm in a field of view of 300 μm. The spectral response efficiencies at 11.4 and 17.48 keV were 7.41 × 10−8 and 5.77 × 10−8 sr, which deviate from the theoretical values by 3.01% and 6.79%, respectively.