In modern smart grids, accurate and synchronized time signals are essential for effective monitoring, protection, and control. Various time synchronization methods exist, each tailored to specific application needs. Widely adopted solutions, such as GPS, however, are vulnerable to challenges such as signal loss and cyber-attacks, underscoring the need for reliable backup or supplementary solutions. This paper examines the timing requirements across different power grid applications and provides a comprehensive review of available time synchronization mechanisms. Through a comparative analysis of timing methods based on accuracy, flexibility, reliability, and security, this study offers insights to guide the selection of optimal solutions for seamless grid integration.
6 September 2023 in IEEE Transactions on Industrial Electronics
The frequency measurement and rate of change of frequency (RoCoF) calculations are important for active power, frequency control, and frequency-related protection in power system operations. With the rapid decrease in inertia under modern power systems, however, multiple power variations introduced by variable renewable energy bring large RoCoF and introduce oscillations in frequency measurements. To shed light on this issue, this article proposes a frequency measurement and RoCoF analysis technology, as well as the sensitivity analysis for the real low-inertia power grid. First, a real-world event in an island power grid is analyzed as an example, and an event numerical model is estimated considering four uncertainties, including event RoCoF, oscillation magnitude, oscillation frequency, and underfrequency load-shedding threshold. Then, a sensitivity analysis is performed using the Sobol indices method and quasi-Monte Carlo simulations to identify the dominant uncertainties based on the event model. The dominant uncertainties are compared to provide a guideline for the frequency estimation algorithm selection under different event cases. This algorithm is compared with an enhanced zero-crossing algorithm and gives a 3.41% better RoCoF error rate. Finally, an experiment is conducted using universal grid analyzers to validate the simulation results and the theoretical analysis.
Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. To achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.
The smart grid aims to provide economically efficient and sustainable power to consumers with high quality and security. However, the increasing integration of distributed renewable energy sources presents challenges for smart grid protection and control systems. To enhance smart grid operations, this article introduces White Rabbit (WR) as a more precise and accurate time synchronization technique. To explore White Rabbit’s potential applications in the smart grid, this study first explains existing time synchronization techniques and their limitations, followed by an analysis of the role and importance of time synchronization in smart grids. A comprehensive survey is then conducted, covering the theories, principles, implementations, performances, and existing application cases of White Rabbit. The findings suggest that White Rabbit is a promising technique for smart grid deployment. However, several challenges remain on the path to large-scale implementation. These challenges are analyzed in detail, highlighting key areas for future research.
31 January 2023 in International Journal of Electrical Power & Energy Systems
Protection relays are important equipment used for protection, control, and metering functions in the power grid. These relays are used to protect critical and difficult-to-replace equipment, like generators, transformers, and capacitor banks. Once the protection devices are disturbed or damaged, a high risk of power generation interruption occurs. Therefore, it is important and necessary to study the relay’s immunity to electromagnetic pulse (EMP) events. As a preliminary step toward empirical experimentation on actual equipment, this manuscript outlines an economical and efficient methodology for evaluating the impact of an EMP. An impedance measurement strategy was employed to model the equipment, setting the stage for subsequent immunity analyses. These analyses included the pulse current injection (PCI) method, which utilized an injecting probe to introduce the transient, and frequency domain electromagnetic (FEKO) simulation, which integrated electromagnetic coupling effects into the transient simulation. The impedance measurement and simulation results in this paper provide a reliable basis for gauging equipment performance in the face of HEMP threats. The results obtained using the PCI and FEKO simulations demonstrated the performance of different port responses under a high-altitude EMP, indicating the requirement for some protection to ensure the reliable operation of relays.