Yeha Lee

Yeha Lee


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2021 in Journal of Medical Internet Research
Verified
Journal Article
Open access
CHChangho Han
Changho Han
YSYoungjae Song
Youngjae Song
HLHong-Seok Lim
Hong-Seok Lim
YTYunwon Tae
Yunwon Tae
JJJong-Hwan Jang
Jong-Hwan Jang
DYDukyong Yoon
Dukyong Yoon
Background: When using a smartwatch to obtain electrocardiogram (ECG) signals from multiple leads, the device has to be placed on different parts of the body sequentially. The ECG signals measured from different leads are asynchronous. Artificial intelligence (AI) models for asynchronous ECG signals have barely been explored. Objective: We aimed to develop an AI model for detecting acute myocardial infarction using asynchronous ECGs and compare its performance with that of the automatic ECG interpretations provided by a commercial ECG analysis software. We sought to evaluate the feasibility of implementing multiple lead–based AI-enabled ECG algorithms on smartwatches. Moreover, we aimed to determine the optimal number of leads for sufficient diagnostic power. Methods: We extracted ECGs recorded within 24 hours from each visit to the emergency room of Ajou University Medical Center between June 1994 and January 2018 from patients aged 20 years or older. The ECGs were labeled on the basis of whether a diagnostic code corresponding to acute myocardial infarction was entered. We derived asynchronous ECG lead sets from standard 12-lead ECG reports and simulated a situation similar to the sequential recording of ECG leads via smartwatches. We constructed an AI model based on residual networks and self-attention mechanisms by randomly masking each lead channel during the training phase and then testing the model using various targeting lead sets with the remaining lead channels masked. Results: The performance of lead sets with 3 or more leads compared favorably with that of the automatic ECG interpretations provided by a commercial ECG analysis software, with 8.1%-13.9% gain in sensitivity when the specificity was matched. Our results indicate that multiple lead-based AI-enabled ECG algorithms can be implemented on smartwatches. Model performance generally increased as the number of leads increased (12-lead sets: area under the receiver operating characteristic curve [AUROC] 0.880; 4-lead sets: AUROC 0.858, SD 0.008; 3-lead sets: AUROC 0.845, SD 0.011; 2-lead sets: AUROC 0.813, SD 0.018; single-lead sets: AUROC 0.768, SD 0.001). Considering the short amount of time needed to measure additional leads, measuring at least 3 leads—ideally more than 4 leads—is necessary for minimizing the risk of failing to detect acute myocardial infarction occurring in a certain spatial location or direction. Conclusions: By developing an AI model for detecting acute myocardial infarction with asynchronous ECG lead sets, we demonstrated the feasibility of multiple lead-based AI-enabled ECG algorithms on smartwatches for automated diagnosis of cardiac disorders. We also demonstrated the necessity of measuring at least 3 leads for accurate detection. Our results can be used as reference for the development of other AI models using sequentially measured asynchronous ECG leads via smartwatches for detecting various cardiac disorders.

17 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TKTaehwa Kim
Taehwa Kim
YTYunwon Tae
Yunwon Tae
HYHye Ju Yeo
Hye Ju Yeo
JJJin Ho Jang
Jin Ho Jang
KCKyungjae Cho
Kyungjae Cho
WCWoo Hyun Cho
Woo Hyun Cho
Background: Successful sepsis treatment depends on early diagnosis. We aimed to develop and validate a system to predict sepsis and septic shock in real time using deep learning. Methods: Clinical data were retrospectively collected from electronic medical records (EMRs). Data from 2010 to 2019 were used as development data, and data from 2020 to 2021 were used as validation data. The collected EMRs consisted of eight vital signs, 13 laboratory data points, and three demographic information items. We validated the deep-learning-based sepsis and septic shock early prediction system (DeepSEPS) using the validation datasets and compared our system with other traditional early warning scoring systems, such as the national early warning score, sequential organ failure assessment (SOFA), and quick sequential organ failure assessment. Results: DeepSEPS achieved even higher area under receiver operating characteristic curve (AUROC) values (0.7888 and 0.8494 for sepsis and septic shock, respectively) than SOFA. The prediction performance of traditional scoring systems was enhanced because the early prediction time point was close to the onset time of sepsis; however, the DeepSEPS scoring system consistently outperformed all conventional scoring systems at all time points. Furthermore, at the time of onset of sepsis and septic shock, DeepSEPS showed the highest AUROC (0.9346). Conclusions: The sepsis and septic shock early warning system developed in this study exhibited a performance that is worth considering when predicting sepsis and septic shock compared to other traditional early warning scoring systems. DeepSEPS showed better performance than existing sepsis prediction programs. This novel real-time system that simultaneously predicts sepsis and septic shock requires further validation.

1 January 2022 in Journal of Korean Medical Science
Verified
Journal Article
Open access
PDF file
RKRyoung-Eun Ko
Ryoung-Eun Ko
OKOyeon Kwon
Oyeon Kwon
KCKyungjae Cho
Kyungjae Cho
YLYeon Joo Lee
Yeon Joo Lee
JKJoon-myoung Kwon
Joon-myoung Kwon
Kyeongman JeonKyeongman Jeon
Kyeongman Jeon
Ko RE, et al. J Korean Med Sci. 2022 Apr;37(16):e122. https://doi.org/10.3346/jkms.2022.37.e122

26 October 2022 in Acute and Critical Care
Verified
Journal Article
Open access
PDF file
YSYunseob Shin
Yunseob Shin
KCKyungjae Cho
Kyungjae Cho
YLYeha Lee
Yeha Lee
YCYu Hyeon Choi
Yu Hyeon Choi
JJJae Hwa Jung
Jae Hwa Jung
WJWon Kyoung Jhang
Won Kyoung Jhang
Background: Early recognition of deterioration events is crucial to improve clinical outcomes. For this purpose, we developed a deep-learning-based pediatric early-warning system (pDEWS) and aimed to validate its clinical performance. Methods: This is a retrospective multicenter cohort study including five tertiary-care academic children’s hospitals. All pediatric patients younger than 19 years admitted to the general ward from January 2019 to December 2019 were included. Using patient electronic medical records, we evaluated the clinical performance of the pDEWS for identifying deterioration events defined as in-hospital cardiac arrest (IHCA) and unexpected general ward-to-pediatric intensive care unit transfer (UIT) within 24 hours before event occurrence. We also compared pDEWS performance to those of the modified pediatric early-warning score (PEWS) and prediction models using logistic regression (LR) and random forest (RF). Results: The study population consisted of 28,758 patients with 34 cases of IHCA and 291 cases of UIT. pDEWS showed better performance for predicting deterioration events with a larger area under the receiver operating characteristic curve, fewer false alarms, a lower mean alarm count per day, and a smaller number of cases needed to examine than the modified PEWS, LR, or RF models regardless of site, event occurrence time, age group, or sex. Conclusions: The pDEWS outperformed modified PEWS, LR, and RF models for early and accurate prediction of deterioration events regardless of clinical situation. This study demonstrated the potential of pDEWS as an efficient screening tool for efferent operation of rapid response teams.

1 January 2023 in Journal of Cardiovascular Intervention
Verified
Journal Article
Open access
PDF file
BLByeong Tak Lee
Byeong Tak Lee
JKJoon-myoung Kwon
Joon-myoung Kwon
JCJinwoo Cho
Jinwoo Cho
WBWoong Bae
Woong Bae
HPHyunho Park
Hyunho Park
KJKi-Hyun Jeon
Ki-Hyun Jeon
Lee BT, et al. J Cardiovasc Interv. 2023 Mar;2:e13. https://doi.org/10.54912/jci.2022.0028

18 September 2020 in Critical Care Medicine
Verified
Journal Article
Closed access
BLByeong Tak Lee
Byeong Tak Lee
OKO-Yeon Kwon
O-Yeon Kwon
HPHyunho Park
Hyunho Park
KCKyung-Jae Cho
Kyung-Jae Cho
JKJoon-Myoung Kwon
Joon-Myoung Kwon
YLYeha Lee
Yeha Lee
Objectives: A deep learning-based early warning system is proposed to predict sepsis prior to its onset. Design: A novel algorithm was devised to detect sepsis 6 hours prior to its onset based on electronic medical records. Setting: Retrospective cohorts from three separate hospitals are used in this study. Sepsis onset was defined based on Sepsis-3. Algorithms are evaluated based on the score function used in the Physionet Challenge 2019.Patients: Over 60,000 ICU patients with 40 clinical variables (vital signs, laboratory results) for each hour of a patient’s ICU stay were used. Interventions: None. Measurements and Main Results: The proposed algorithm predicted the onset of sepsis in the preceding n hours (where n = 4, 6, 8, or 12). Furthermore, the proposed method compared how many sepsis patients can be predicted in a short time with other methods. To interpret a given result in a clinical perspective, the relationship between input variables and the probability of the proposed method were presented. The proposed method achieved superior results (area under the receiver operating characteristic curve, area under the precision-recall curve, and score) and predicted more sepsis patients in advance. In official phase, the proposed method showed the utility score of –0.101, area under the receiver operating characteristic curve 0.782, area under the precision-recall curve 0.041, accuracy 0.786, and F-measure 0.046. Conclusions: Using Physionet Challenge 2019, the proposed method can accurately and early predict the onset of sepsis. The proposed method can be a practical early warning system in the environment of real hospitals.